ABAP Select data from SAP table FACV_UH_NOTIF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FACV_UH_NOTIF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FACV_UH_NOTIF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FACV_UH_NOTIF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FACV_UH_NOTIF TYPE STANDARD TABLE OF FACV_UH_NOTIF,
      WA_FACV_UH_NOTIF TYPE FACV_UH_NOTIF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FACV_UH_NOTIF> TYPE FACV_UH_NOTIF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FACV_UH_NOTIF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FACV_UH_NOTIF
  INTO TABLE IT_FACV_UH_NOTIF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FACV_UH_NOTIF
*  INTO TABLE @DATA(IT_FACV_UH_NOTIF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FACV_UH_NOTIF INDEX 1 INTO DATA(WA_FACV_UH_NOTIF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FACV_UH_NOTIF ASSIGNING <FACV_UH_NOTIF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FACV_UH_NOTIF>-MANDT = 1.
<FACV_UH_NOTIF>-VERSIONID = 1.
<FACV_UH_NOTIF>-OBJECTKEY = 1.
<FACV_UH_NOTIF>-OBJECTID = 1.
<FACV_UH_NOTIF>-HIERARCHYCATEGORY = 1.
ENDLOOP.

LOOP AT IT_FACV_UH_NOTIF INTO WA_FACV_UH_NOTIF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FACV_UH_NOTIF-OBJECTTYPE, sy-vline,
WA_FACV_UH_NOTIF-CATEGORYTEXT, sy-vline,
WA_FACV_UH_NOTIF-HIERARCHYID, sy-vline,
WA_FACV_UH_NOTIF-BUSINESSENTITYNAME, sy-vline,
WA_FACV_UH_NOTIF-BUSINESSENTITYTEXT, sy-vline,
WA_FACV_UH_NOTIF-HIERARCHYDESCRIPTION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FACV_UH_NOTIF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FACV_UH_NOTIF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FACV_UH_NOTIF INTO WA_FACV_UH_NOTIF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FACV_UH_NOTIF_STR,
MANDT TYPE STRING,
VERSIONID TYPE STRING,
OBJECTKEY TYPE STRING,
OBJECTID TYPE STRING,
HIERARCHYCATEGORY TYPE STRING,
OBJECTTYPE TYPE STRING,
CATEGORYTEXT TYPE STRING,
HIERARCHYID TYPE STRING,
BUSINESSENTITYNAME TYPE STRING,
BUSINESSENTITYTEXT TYPE STRING,
HIERARCHYDESCRIPTION TYPE STRING,
VALIDFROM TYPE STRING,
VALIDTO TYPE STRING,
HIERARCHYVERSIONTEXT TYPE STRING,
VERSIONSTATUS TYPE STRING,
CREATEDON TYPE STRING,END OF T_EKKO_STR. DATA: WA_FACV_UH_NOTIF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FACV_UH_NOTIF_STR-MANDT sy-vline
WA_FACV_UH_NOTIF_STR-VERSIONID sy-vline
WA_FACV_UH_NOTIF_STR-OBJECTKEY sy-vline
WA_FACV_UH_NOTIF_STR-OBJECTID sy-vline
WA_FACV_UH_NOTIF_STR-HIERARCHYCATEGORY sy-vline
WA_FACV_UH_NOTIF_STR-OBJECTTYPE sy-vline
WA_FACV_UH_NOTIF_STR-CATEGORYTEXT sy-vline
WA_FACV_UH_NOTIF_STR-HIERARCHYID sy-vline
WA_FACV_UH_NOTIF_STR-BUSINESSENTITYNAME sy-vline
WA_FACV_UH_NOTIF_STR-BUSINESSENTITYTEXT sy-vline
WA_FACV_UH_NOTIF_STR-HIERARCHYDESCRIPTION sy-vline
WA_FACV_UH_NOTIF_STR-VALIDFROM sy-vline
WA_FACV_UH_NOTIF_STR-VALIDTO sy-vline
WA_FACV_UH_NOTIF_STR-HIERARCHYVERSIONTEXT sy-vline
WA_FACV_UH_NOTIF_STR-VERSIONSTATUS sy-vline
WA_FACV_UH_NOTIF_STR-CREATEDON sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.