ABAP Select data from SAP table FACUHMIGITYCD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FACUHMIGITYCD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FACUHMIGITYCD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FACUHMIGITYCD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FACUHMIGITYCD TYPE STANDARD TABLE OF FACUHMIGITYCD,
      WA_FACUHMIGITYCD TYPE FACUHMIGITYCD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FACUHMIGITYCD> TYPE FACUHMIGITYCD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FACUHMIGITYCD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FACUHMIGITYCD
  INTO TABLE IT_FACUHMIGITYCD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FACUHMIGITYCD
*  INTO TABLE @DATA(IT_FACUHMIGITYCD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FACUHMIGITYCD INDEX 1 INTO DATA(WA_FACUHMIGITYCD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FACUHMIGITYCD ASSIGNING <FACUHMIGITYCD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FACUHMIGITYCD>-MANDT = 1.
<FACUHMIGITYCD>-HIERARCHYTYPE = 1.
<FACUHMIGITYCD>-HIERARCHYOLDID = 1.
<FACUHMIGITYCD>-SUBCLASS = 1.
<FACUHMIGITYCD>-CHANGEDBY = 1.
ENDLOOP.

LOOP AT IT_FACUHMIGITYCD INTO WA_FACUHMIGITYCD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FACUHMIGITYCD-CHANGEDON, sy-vline,
WA_FACUHMIGITYCD-CHANGEDAT, sy-vline,
WA_FACUHMIGITYCD-ACTION, sy-vline,
WA_FACUHMIGITYCD-FIELD, sy-vline,
WA_FACUHMIGITYCD-FIELDTEXT, sy-vline,
WA_FACUHMIGITYCD-OLDVALUE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FACUHMIGITYCD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FACUHMIGITYCD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FACUHMIGITYCD INTO WA_FACUHMIGITYCD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FACUHMIGITYCD_STR,
MANDT TYPE STRING,
HIERARCHYTYPE TYPE STRING,
HIERARCHYOLDID TYPE STRING,
SUBCLASS TYPE STRING,
CHANGEDBY TYPE STRING,
CHANGEDON TYPE STRING,
CHANGEDAT TYPE STRING,
ACTION TYPE STRING,
FIELD TYPE STRING,
FIELDTEXT TYPE STRING,
OLDVALUE TYPE STRING,
NEWVALUE TYPE STRING,END OF T_EKKO_STR. DATA: WA_FACUHMIGITYCD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FACUHMIGITYCD_STR-MANDT sy-vline
WA_FACUHMIGITYCD_STR-HIERARCHYTYPE sy-vline
WA_FACUHMIGITYCD_STR-HIERARCHYOLDID sy-vline
WA_FACUHMIGITYCD_STR-SUBCLASS sy-vline
WA_FACUHMIGITYCD_STR-CHANGEDBY sy-vline
WA_FACUHMIGITYCD_STR-CHANGEDON sy-vline
WA_FACUHMIGITYCD_STR-CHANGEDAT sy-vline
WA_FACUHMIGITYCD_STR-ACTION sy-vline
WA_FACUHMIGITYCD_STR-FIELD sy-vline
WA_FACUHMIGITYCD_STR-FIELDTEXT sy-vline
WA_FACUHMIGITYCD_STR-OLDVALUE sy-vline
WA_FACUHMIGITYCD_STR-NEWVALUE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.