ABAP Select data from SAP table FACRA_ITEM_PER_EXT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FACRA_ITEM_PER_EXT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FACRA_ITEM_PER_EXT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FACRA_ITEM_PER_EXT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FACRA_ITEM_PER_EXT TYPE STANDARD TABLE OF FACRA_ITEM_PER_EXT,
      WA_FACRA_ITEM_PER_EXT TYPE FACRA_ITEM_PER_EXT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FACRA_ITEM_PER_EXT> TYPE FACRA_ITEM_PER_EXT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FACRA_ITEM_PER_EXT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FACRA_ITEM_PER_EXT
  INTO TABLE IT_FACRA_ITEM_PER_EXT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FACRA_ITEM_PER_EXT
*  INTO TABLE @DATA(IT_FACRA_ITEM_PER_EXT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FACRA_ITEM_PER_EXT INDEX 1 INTO DATA(WA_FACRA_ITEM_PER_EXT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FACRA_ITEM_PER_EXT ASSIGNING <FACRA_ITEM_PER_EXT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FACRA_ITEM_PER_EXT>-ITEMTYPE = 1.
<FACRA_ITEM_PER_EXT>-RLDNR = 1.
<FACRA_ITEM_PER_EXT>-CRCY_TYPE = 1.
<FACRA_ITEM_PER_EXT>-ADJSTMNT_REASON = 1.
<FACRA_ITEM_PER_EXT>-ADJSTMNT_COMMENT = 1.
ENDLOOP.

LOOP AT IT_FACRA_ITEM_PER_EXT INTO WA_FACRA_ITEM_PER_EXT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FACRA_ITEM_PER_EXT-ADJUSTED_BY, sy-vline,
WA_FACRA_ITEM_PER_EXT-ADJUSTED_ON, sy-vline,
WA_FACRA_ITEM_PER_EXT-ADJUSTED_AT, sy-vline,
WA_FACRA_ITEM_PER_EXT-REVIEW_STATUS, sy-vline,
WA_FACRA_ITEM_PER_EXT-REVIEW_TYPE, sy-vline,
WA_FACRA_ITEM_PER_EXT-REVIEWED_BY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FACRA_ITEM_PER_EXT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FACRA_ITEM_PER_EXT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FACRA_ITEM_PER_EXT INTO WA_FACRA_ITEM_PER_EXT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ITEMTYPE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FACRA_ITEM_PER_EXT-ITEMTYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FACRA_ITEM_PER_EXT-ITEMTYPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FACRA_ITEM_PER_EXT-RLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FACRA_ITEM_PER_EXT-RLDNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FACRA_ITEM_PER_EXT_STR,
ITEMTYPE TYPE STRING,
RLDNR TYPE STRING,
CRCY_TYPE TYPE STRING,
ADJSTMNT_REASON TYPE STRING,
ADJSTMNT_COMMENT TYPE STRING,
ADJUSTED_BY TYPE STRING,
ADJUSTED_ON TYPE STRING,
ADJUSTED_AT TYPE STRING,
REVIEW_STATUS TYPE STRING,
REVIEW_TYPE TYPE STRING,
REVIEWED_BY TYPE STRING,
REVIEWED_ON TYPE STRING,
REVIEWED_AT TYPE STRING,
APPROVAL_STATUS TYPE STRING,
APPROVAL_TYPE TYPE STRING,
APPROVED_BY TYPE STRING,
APPROVED_ON TYPE STRING,
APPROVED_AT TYPE STRING,
XREVIEWED TYPE STRING,
XAPPROVED TYPE STRING,
ADJMT_AMNT TYPE STRING,
WAERS TYPE STRING,END OF T_EKKO_STR. DATA: WA_FACRA_ITEM_PER_EXT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FACRA_ITEM_PER_EXT_STR-ITEMTYPE sy-vline
WA_FACRA_ITEM_PER_EXT_STR-RLDNR sy-vline
WA_FACRA_ITEM_PER_EXT_STR-CRCY_TYPE sy-vline
WA_FACRA_ITEM_PER_EXT_STR-ADJSTMNT_REASON sy-vline
WA_FACRA_ITEM_PER_EXT_STR-ADJSTMNT_COMMENT sy-vline
WA_FACRA_ITEM_PER_EXT_STR-ADJUSTED_BY sy-vline
WA_FACRA_ITEM_PER_EXT_STR-ADJUSTED_ON sy-vline
WA_FACRA_ITEM_PER_EXT_STR-ADJUSTED_AT sy-vline
WA_FACRA_ITEM_PER_EXT_STR-REVIEW_STATUS sy-vline
WA_FACRA_ITEM_PER_EXT_STR-REVIEW_TYPE sy-vline
WA_FACRA_ITEM_PER_EXT_STR-REVIEWED_BY sy-vline
WA_FACRA_ITEM_PER_EXT_STR-REVIEWED_ON sy-vline
WA_FACRA_ITEM_PER_EXT_STR-REVIEWED_AT sy-vline
WA_FACRA_ITEM_PER_EXT_STR-APPROVAL_STATUS sy-vline
WA_FACRA_ITEM_PER_EXT_STR-APPROVAL_TYPE sy-vline
WA_FACRA_ITEM_PER_EXT_STR-APPROVED_BY sy-vline
WA_FACRA_ITEM_PER_EXT_STR-APPROVED_ON sy-vline
WA_FACRA_ITEM_PER_EXT_STR-APPROVED_AT sy-vline
WA_FACRA_ITEM_PER_EXT_STR-XREVIEWED sy-vline
WA_FACRA_ITEM_PER_EXT_STR-XAPPROVED sy-vline
WA_FACRA_ITEM_PER_EXT_STR-ADJMT_AMNT sy-vline
WA_FACRA_ITEM_PER_EXT_STR-WAERS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.