ABAP Select data from SAP table FACM_S_RFFDIS46_LIST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FACM_S_RFFDIS46_LIST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FACM_S_RFFDIS46_LIST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FACM_S_RFFDIS46_LIST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FACM_S_RFFDIS46_LIST TYPE STANDARD TABLE OF FACM_S_RFFDIS46_LIST,
      WA_FACM_S_RFFDIS46_LIST TYPE FACM_S_RFFDIS46_LIST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FACM_S_RFFDIS46_LIST> TYPE FACM_S_RFFDIS46_LIST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FACM_S_RFFDIS46_LIST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FACM_S_RFFDIS46_LIST
  INTO TABLE IT_FACM_S_RFFDIS46_LIST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FACM_S_RFFDIS46_LIST
*  INTO TABLE @DATA(IT_FACM_S_RFFDIS46_LIST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FACM_S_RFFDIS46_LIST INDEX 1 INTO DATA(WA_FACM_S_RFFDIS46_LIST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FACM_S_RFFDIS46_LIST ASSIGNING <FACM_S_RFFDIS46_LIST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FACM_S_RFFDIS46_LIST>-WAERS = 1.
<FACM_S_RFFDIS46_LIST>-SAKNR = 1.
<FACM_S_RFFDIS46_LIST>-VALUT = 1.
<FACM_S_RFFDIS46_LIST>-KWBTR = 1.
<FACM_S_RFFDIS46_LIST>-WRBTR = 1.
ENDLOOP.

LOOP AT IT_FACM_S_RFFDIS46_LIST INTO WA_FACM_S_RFFDIS46_LIST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FACM_S_RFFDIS46_LIST-XBLNR, sy-vline,
WA_FACM_S_RFFDIS46_LIST-CHECKBOX, sy-vline,
WA_FACM_S_RFFDIS46_LIST-BELNR, sy-vline,
WA_FACM_S_RFFDIS46_LIST-IDENR, sy-vline,
WA_FACM_S_RFFDIS46_LIST-DATUM, sy-vline,
WA_FACM_S_RFFDIS46_LIST-EBENE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FACM_S_RFFDIS46_LIST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FACM_S_RFFDIS46_LIST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FACM_S_RFFDIS46_LIST INTO WA_FACM_S_RFFDIS46_LIST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SAKNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FACM_S_RFFDIS46_LIST-SAKNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FACM_S_RFFDIS46_LIST-SAKNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field KWBTR CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_FACM_S_RFFDIS46_LIST-KWBTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FACM_S_RFFDIS46_LIST-KWBTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field WRBTR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FACM_S_RFFDIS46_LIST-WRBTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FACM_S_RFFDIS46_LIST-WRBTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FACM_S_RFFDIS46_LIST-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FACM_S_RFFDIS46_LIST-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WRSHB CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FACM_S_RFFDIS46_LIST-WRSHB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FACM_S_RFFDIS46_LIST-WRSHB.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FACM_S_RFFDIS46_LIST_STR,
WAERS TYPE STRING,
SAKNR TYPE STRING,
VALUT TYPE STRING,
KWBTR TYPE STRING,
WRBTR TYPE STRING,
XBLNR TYPE STRING,
CHECKBOX TYPE STRING,
BELNR TYPE STRING,
IDENR TYPE STRING,
DATUM TYPE STRING,
EBENE TYPE STRING,
DSART TYPE STRING,
WRSHB TYPE STRING,
MERKM TYPE STRING,
SGTXT TYPE STRING,
BUKRS TYPE STRING,END OF T_EKKO_STR. DATA: WA_FACM_S_RFFDIS46_LIST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FACM_S_RFFDIS46_LIST_STR-WAERS sy-vline
WA_FACM_S_RFFDIS46_LIST_STR-SAKNR sy-vline
WA_FACM_S_RFFDIS46_LIST_STR-VALUT sy-vline
WA_FACM_S_RFFDIS46_LIST_STR-KWBTR sy-vline
WA_FACM_S_RFFDIS46_LIST_STR-WRBTR sy-vline
WA_FACM_S_RFFDIS46_LIST_STR-XBLNR sy-vline
WA_FACM_S_RFFDIS46_LIST_STR-CHECKBOX sy-vline
WA_FACM_S_RFFDIS46_LIST_STR-BELNR sy-vline
WA_FACM_S_RFFDIS46_LIST_STR-IDENR sy-vline
WA_FACM_S_RFFDIS46_LIST_STR-DATUM sy-vline
WA_FACM_S_RFFDIS46_LIST_STR-EBENE sy-vline
WA_FACM_S_RFFDIS46_LIST_STR-DSART sy-vline
WA_FACM_S_RFFDIS46_LIST_STR-WRSHB sy-vline
WA_FACM_S_RFFDIS46_LIST_STR-MERKM sy-vline
WA_FACM_S_RFFDIS46_LIST_STR-SGTXT sy-vline
WA_FACM_S_RFFDIS46_LIST_STR-BUKRS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.