ABAP Select data from SAP table FAC_S_RJET_ITEM_ODATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FAC_S_RJET_ITEM_ODATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FAC_S_RJET_ITEM_ODATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FAC_S_RJET_ITEM_ODATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FAC_S_RJET_ITEM_ODATA TYPE STANDARD TABLE OF FAC_S_RJET_ITEM_ODATA,
      WA_FAC_S_RJET_ITEM_ODATA TYPE FAC_S_RJET_ITEM_ODATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FAC_S_RJET_ITEM_ODATA> TYPE FAC_S_RJET_ITEM_ODATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FAC_S_RJET_ITEM_ODATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FAC_S_RJET_ITEM_ODATA
  INTO TABLE IT_FAC_S_RJET_ITEM_ODATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FAC_S_RJET_ITEM_ODATA
*  INTO TABLE @DATA(IT_FAC_S_RJET_ITEM_ODATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FAC_S_RJET_ITEM_ODATA INDEX 1 INTO DATA(WA_FAC_S_RJET_ITEM_ODATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FAC_S_RJET_ITEM_ODATA ASSIGNING <FAC_S_RJET_ITEM_ODATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FAC_S_RJET_ITEM_ODATA>-BUKRS = 1.
<FAC_S_RJET_ITEM_ODATA>-BUKRS_TXT = 1.
<FAC_S_RJET_ITEM_ODATA>-BELNR = 1.
<FAC_S_RJET_ITEM_ODATA>-GJAHR = 1.
<FAC_S_RJET_ITEM_ODATA>-BKTXT = 1.
ENDLOOP.

LOOP AT IT_FAC_S_RJET_ITEM_ODATA INTO WA_FAC_S_RJET_ITEM_ODATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FAC_S_RJET_ITEM_ODATA-NUMBER_NOT_POSTED_JES, sy-vline,
WA_FAC_S_RJET_ITEM_ODATA-POSTED_VS_TOTAL_JES, sy-vline,
WA_FAC_S_RJET_ITEM_ODATA-NUMBER_REVERSED_JES, sy-vline,
WA_FAC_S_RJET_ITEM_ODATA-TOTAL_AMT_TRANS_CURR, sy-vline,
WA_FAC_S_RJET_ITEM_ODATA-TOTAL_P_AMT_TCURR, sy-vline,
WA_FAC_S_RJET_ITEM_ODATA-TOTAL_NYP_AMT_TCURR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FAC_S_RJET_ITEM_ODATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FAC_S_RJET_ITEM_ODATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FAC_S_RJET_ITEM_ODATA INTO WA_FAC_S_RJET_ITEM_ODATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FAC_S_RJET_ITEM_ODATA-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_RJET_ITEM_ODATA-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FAC_S_RJET_ITEM_ODATA-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_RJET_ITEM_ODATA-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field TOTAL_AMT_TRANS_CURR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FAC_S_RJET_ITEM_ODATA-TOTAL_AMT_TRANS_CURR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_RJET_ITEM_ODATA-TOTAL_AMT_TRANS_CURR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field TOTAL_P_AMT_TCURR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FAC_S_RJET_ITEM_ODATA-TOTAL_P_AMT_TCURR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_RJET_ITEM_ODATA-TOTAL_P_AMT_TCURR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field TOTAL_NYP_AMT_TCURR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FAC_S_RJET_ITEM_ODATA-TOTAL_NYP_AMT_TCURR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_RJET_ITEM_ODATA-TOTAL_NYP_AMT_TCURR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field TOTAL_AMT_DISPL_CURR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FAC_S_RJET_ITEM_ODATA-TOTAL_AMT_DISPL_CURR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_RJET_ITEM_ODATA-TOTAL_AMT_DISPL_CURR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field TOTAL_P_AMT_DCURR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FAC_S_RJET_ITEM_ODATA-TOTAL_P_AMT_DCURR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_RJET_ITEM_ODATA-TOTAL_P_AMT_DCURR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field TOTAL_NYP_AMT_DCURR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FAC_S_RJET_ITEM_ODATA-TOTAL_NYP_AMT_DCURR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_RJET_ITEM_ODATA-TOTAL_NYP_AMT_DCURR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field TOTAL_AMT_LOCAL_CURR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FAC_S_RJET_ITEM_ODATA-TOTAL_AMT_LOCAL_CURR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_RJET_ITEM_ODATA-TOTAL_AMT_LOCAL_CURR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field TOTAL_NYP_AMT_LCURR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FAC_S_RJET_ITEM_ODATA-TOTAL_NYP_AMT_LCURR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_RJET_ITEM_ODATA-TOTAL_NYP_AMT_LCURR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field TOTAL_P_AMT_LCURR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FAC_S_RJET_ITEM_ODATA-TOTAL_P_AMT_LCURR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_RJET_ITEM_ODATA-TOTAL_P_AMT_LCURR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field TOTAL_AMT_FUNCT_CURR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FAC_S_RJET_ITEM_ODATA-TOTAL_AMT_FUNCT_CURR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_RJET_ITEM_ODATA-TOTAL_AMT_FUNCT_CURR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field TOTAL_NYP_AMT_FCURR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FAC_S_RJET_ITEM_ODATA-TOTAL_NYP_AMT_FCURR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_RJET_ITEM_ODATA-TOTAL_NYP_AMT_FCURR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field TOTAL_P_AMT_FCURR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FAC_S_RJET_ITEM_ODATA-TOTAL_P_AMT_FCURR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_RJET_ITEM_ODATA-TOTAL_P_AMT_FCURR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field KURSF CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_FAC_S_RJET_ITEM_ODATA-KURSF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_RJET_ITEM_ODATA-KURSF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field AMT_TRANS_CURR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FAC_S_RJET_ITEM_ODATA-AMT_TRANS_CURR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_RJET_ITEM_ODATA-AMT_TRANS_CURR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field AMT_DISPLAY_CURR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FAC_S_RJET_ITEM_ODATA-AMT_DISPLAY_CURR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_RJET_ITEM_ODATA-AMT_DISPLAY_CURR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field AMT_LOCAL_CURR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FAC_S_RJET_ITEM_ODATA-AMT_LOCAL_CURR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_RJET_ITEM_ODATA-AMT_LOCAL_CURR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field AMT_FUNCT_CURR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FAC_S_RJET_ITEM_ODATA-AMT_FUNCT_CURR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_RJET_ITEM_ODATA-AMT_FUNCT_CURR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FAC_S_RJET_ITEM_ODATA_STR,
BUKRS TYPE STRING,
BUKRS_TXT TYPE STRING,
BELNR TYPE STRING,
GJAHR TYPE STRING,
BKTXT TYPE STRING,
NUMBER_NOT_POSTED_JES TYPE STRING,
POSTED_VS_TOTAL_JES TYPE STRING,
NUMBER_REVERSED_JES TYPE STRING,
TOTAL_AMT_TRANS_CURR TYPE STRING,
TOTAL_P_AMT_TCURR TYPE STRING,
TOTAL_NYP_AMT_TCURR TYPE STRING,
TRANS_CURR TYPE STRING,
TOTAL_AMT_DISPL_CURR TYPE STRING,
TOTAL_P_AMT_DCURR TYPE STRING,
TOTAL_NYP_AMT_DCURR TYPE STRING,
DISPL_CURR TYPE STRING,
LOCAL_CURR TYPE STRING,
FUNCT_CURR TYPE STRING,
TOTAL_AMT_LOCAL_CURR TYPE STRING,
TOTAL_NYP_AMT_LCURR TYPE STRING,
TOTAL_P_AMT_LCURR TYPE STRING,
TOTAL_AMT_FUNCT_CURR TYPE STRING,
TOTAL_NYP_AMT_FCURR TYPE STRING,
TOTAL_P_AMT_FCURR TYPE STRING,
USNAM TYPE STRING,
XBLNR TYPE STRING,
BLART TYPE STRING,
BLART_TXT TYPE STRING,
CPUDT TYPE STRING,
CPUTM TYPE STRING,
KURSF TYPE STRING,
KURSF_EXT TYPE STRING,
KURST TYPE STRING,
WWERT TYPE STRING,
DBATR TYPE STRING,
DBZHL TYPE STRING,
DBAKZ TYPE STRING,
RECURRENCE_TYPE TYPE STRING,
FREQUENCY TYPE STRING,
OCCUR_DAY_TYPE TYPE STRING,
OCCUR_DAY TYPE STRING,
FIRST_OCCUR_DATE TYPE STRING,
END_BY_TYPE TYPE STRING,
LAST_OCCUR_DATE TYPE STRING,
NUMBER_OF_OCCUR TYPE STRING,
WEEK_DAY TYPE STRING,
MONTH_DAY TYPE STRING,
PERIOD_DAY TYPE STRING,
BLOCKED_FOR_POSTING TYPE STRING,
RECUR_SCHEDULE_USED TYPE STRING,
TRANSFER_LC_AMTS TYPE STRING,
DBAKZ_TXT TYPE STRING,
RECURRENCE_TYPE_TXT TYPE STRING,
OCCUR_DAY_TYPE_TXT TYPE STRING,
WEEK_DAY_TXT TYPE STRING,
END_BY_TYPE_TXT TYPE STRING,
TRANSFER_LC_AMTS_TXT TYPE STRING,
AMT_TRANS_CURR TYPE STRING,
AMT_DISPLAY_CURR TYPE STRING,
AMT_LOCAL_CURR TYPE STRING,
AMT_FUNCT_CURR TYPE STRING,
LOGNUMBER TYPE STRING,
LDGRP TYPE STRING,
LDGRP_TXT TYPE STRING,
MAX_MSG_SEVERITY TYPE STRING,END OF T_EKKO_STR. DATA: WA_FAC_S_RJET_ITEM_ODATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-BUKRS sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-BUKRS_TXT sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-BELNR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-GJAHR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-BKTXT sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-NUMBER_NOT_POSTED_JES sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-POSTED_VS_TOTAL_JES sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-NUMBER_REVERSED_JES sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-TOTAL_AMT_TRANS_CURR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-TOTAL_P_AMT_TCURR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-TOTAL_NYP_AMT_TCURR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-TRANS_CURR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-TOTAL_AMT_DISPL_CURR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-TOTAL_P_AMT_DCURR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-TOTAL_NYP_AMT_DCURR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-DISPL_CURR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-LOCAL_CURR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-FUNCT_CURR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-TOTAL_AMT_LOCAL_CURR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-TOTAL_NYP_AMT_LCURR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-TOTAL_P_AMT_LCURR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-TOTAL_AMT_FUNCT_CURR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-TOTAL_NYP_AMT_FCURR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-TOTAL_P_AMT_FCURR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-USNAM sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-XBLNR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-BLART sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-BLART_TXT sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-CPUDT sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-CPUTM sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-KURSF sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-KURSF_EXT sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-KURST sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-WWERT sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-DBATR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-DBZHL sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-DBAKZ sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-RECURRENCE_TYPE sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-FREQUENCY sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-OCCUR_DAY_TYPE sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-OCCUR_DAY sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-FIRST_OCCUR_DATE sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-END_BY_TYPE sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-LAST_OCCUR_DATE sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-NUMBER_OF_OCCUR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-WEEK_DAY sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-MONTH_DAY sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-PERIOD_DAY sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-BLOCKED_FOR_POSTING sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-RECUR_SCHEDULE_USED sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-TRANSFER_LC_AMTS sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-DBAKZ_TXT sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-RECURRENCE_TYPE_TXT sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-OCCUR_DAY_TYPE_TXT sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-WEEK_DAY_TXT sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-END_BY_TYPE_TXT sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-TRANSFER_LC_AMTS_TXT sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-AMT_TRANS_CURR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-AMT_DISPLAY_CURR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-AMT_LOCAL_CURR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-AMT_FUNCT_CURR sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-LOGNUMBER sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-LDGRP sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-LDGRP_TXT sy-vline
WA_FAC_S_RJET_ITEM_ODATA_STR-MAX_MSG_SEVERITY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.