ABAP Select data from SAP table FAC_S_GL_ACC_COA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FAC_S_GL_ACC_COA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FAC_S_GL_ACC_COA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FAC_S_GL_ACC_COA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FAC_S_GL_ACC_COA TYPE STANDARD TABLE OF FAC_S_GL_ACC_COA,
      WA_FAC_S_GL_ACC_COA TYPE FAC_S_GL_ACC_COA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FAC_S_GL_ACC_COA> TYPE FAC_S_GL_ACC_COA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FAC_S_GL_ACC_COA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FAC_S_GL_ACC_COA
  INTO TABLE IT_FAC_S_GL_ACC_COA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FAC_S_GL_ACC_COA
*  INTO TABLE @DATA(IT_FAC_S_GL_ACC_COA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FAC_S_GL_ACC_COA INDEX 1 INTO DATA(WA_FAC_S_GL_ACC_COA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FAC_S_GL_ACC_COA ASSIGNING <FAC_S_GL_ACC_COA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FAC_S_GL_ACC_COA>-KTOPL = 1.
<FAC_S_GL_ACC_COA>-SAKNR = 1.
<FAC_S_GL_ACC_COA>-TXT20 = 1.
<FAC_S_GL_ACC_COA>-TXT50 = 1.
<FAC_S_GL_ACC_COA>-FKBER = 1.
ENDLOOP.

LOOP AT IT_FAC_S_GL_ACC_COA INTO WA_FAC_S_GL_ACC_COA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FAC_S_GL_ACC_COA-FKBTX, sy-vline,
WA_FAC_S_GL_ACC_COA-BILKT, sy-vline,
WA_FAC_S_GL_ACC_COA-BILKT_TXT, sy-vline,
WA_FAC_S_GL_ACC_COA-USNAM, sy-vline,
WA_FAC_S_GL_ACC_COA-FULLNAME, sy-vline,
WA_FAC_S_GL_ACC_COA-ERDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FAC_S_GL_ACC_COA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FAC_S_GL_ACC_COA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FAC_S_GL_ACC_COA INTO WA_FAC_S_GL_ACC_COA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SAKNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FAC_S_GL_ACC_COA-SAKNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_GL_ACC_COA-SAKNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BILKT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FAC_S_GL_ACC_COA-BILKT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_GL_ACC_COA-BILKT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VBUND CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FAC_S_GL_ACC_COA-VBUND IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_GL_ACC_COA-VBUND.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field DSPRA CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_FAC_S_GL_ACC_COA-DSPRA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_GL_ACC_COA-DSPRA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REF_SAKNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FAC_S_GL_ACC_COA-REF_SAKNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_GL_ACC_COA-REF_SAKNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FAC_S_GL_ACC_COA_STR,
KTOPL TYPE STRING,
SAKNR TYPE STRING,
TXT20 TYPE STRING,
TXT50 TYPE STRING,
FKBER TYPE STRING,
FKBTX TYPE STRING,
BILKT TYPE STRING,
BILKT_TXT TYPE STRING,
USNAM TYPE STRING,
FULLNAME TYPE STRING,
ERDAT TYPE STRING,
XBILK TYPE STRING,
GVTYP TYPE STRING,
GVTYP_T20 TYPE STRING,
KTOKS TYPE STRING,
TXT30 TYPE STRING,
VBUND TYPE STRING,
NAME1 TYPE STRING,
XLOEV TYPE STRING,
XSPEA TYPE STRING,
XSPEB TYPE STRING,
XSPEP TYPE STRING,
HASH TYPE STRING,
KKTPL TYPE STRING,
XCOS TYPE STRING,
GVTYP_NUM TYPE STRING,
DSPRA TYPE STRING,
DTXT20 TYPE STRING,
DTXT50 TYPE STRING,
REF_SAKNR TYPE STRING,
REF_KTOPL TYPE STRING,
REF_TXT20 TYPE STRING,
BUKRS_FROM TYPE STRING,
BUKRS_TO TYPE STRING,
GLACCOUNT_TYPE TYPE STRING,
LINETYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_FAC_S_GL_ACC_COA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FAC_S_GL_ACC_COA_STR-KTOPL sy-vline
WA_FAC_S_GL_ACC_COA_STR-SAKNR sy-vline
WA_FAC_S_GL_ACC_COA_STR-TXT20 sy-vline
WA_FAC_S_GL_ACC_COA_STR-TXT50 sy-vline
WA_FAC_S_GL_ACC_COA_STR-FKBER sy-vline
WA_FAC_S_GL_ACC_COA_STR-FKBTX sy-vline
WA_FAC_S_GL_ACC_COA_STR-BILKT sy-vline
WA_FAC_S_GL_ACC_COA_STR-BILKT_TXT sy-vline
WA_FAC_S_GL_ACC_COA_STR-USNAM sy-vline
WA_FAC_S_GL_ACC_COA_STR-FULLNAME sy-vline
WA_FAC_S_GL_ACC_COA_STR-ERDAT sy-vline
WA_FAC_S_GL_ACC_COA_STR-XBILK sy-vline
WA_FAC_S_GL_ACC_COA_STR-GVTYP sy-vline
WA_FAC_S_GL_ACC_COA_STR-GVTYP_T20 sy-vline
WA_FAC_S_GL_ACC_COA_STR-KTOKS sy-vline
WA_FAC_S_GL_ACC_COA_STR-TXT30 sy-vline
WA_FAC_S_GL_ACC_COA_STR-VBUND sy-vline
WA_FAC_S_GL_ACC_COA_STR-NAME1 sy-vline
WA_FAC_S_GL_ACC_COA_STR-XLOEV sy-vline
WA_FAC_S_GL_ACC_COA_STR-XSPEA sy-vline
WA_FAC_S_GL_ACC_COA_STR-XSPEB sy-vline
WA_FAC_S_GL_ACC_COA_STR-XSPEP sy-vline
WA_FAC_S_GL_ACC_COA_STR-HASH sy-vline
WA_FAC_S_GL_ACC_COA_STR-KKTPL sy-vline
WA_FAC_S_GL_ACC_COA_STR-XCOS sy-vline
WA_FAC_S_GL_ACC_COA_STR-GVTYP_NUM sy-vline
WA_FAC_S_GL_ACC_COA_STR-DSPRA sy-vline
WA_FAC_S_GL_ACC_COA_STR-DTXT20 sy-vline
WA_FAC_S_GL_ACC_COA_STR-DTXT50 sy-vline
WA_FAC_S_GL_ACC_COA_STR-REF_SAKNR sy-vline
WA_FAC_S_GL_ACC_COA_STR-REF_KTOPL sy-vline
WA_FAC_S_GL_ACC_COA_STR-REF_TXT20 sy-vline
WA_FAC_S_GL_ACC_COA_STR-BUKRS_FROM sy-vline
WA_FAC_S_GL_ACC_COA_STR-BUKRS_TO sy-vline
WA_FAC_S_GL_ACC_COA_STR-GLACCOUNT_TYPE sy-vline
WA_FAC_S_GL_ACC_COA_STR-LINETYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.