ABAP Select data from SAP table FAC_OPP_S_NEXT_UPDATE_TIME into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FAC_OPP_S_NEXT_UPDATE_TIME table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FAC_OPP_S_NEXT_UPDATE_TIME. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FAC_OPP_S_NEXT_UPDATE_TIME table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FAC_OPP_S_NEXT_UPDATE_TIME TYPE STANDARD TABLE OF FAC_OPP_S_NEXT_UPDATE_TIME,
      WA_FAC_OPP_S_NEXT_UPDATE_TIME TYPE FAC_OPP_S_NEXT_UPDATE_TIME,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FAC_OPP_S_NEXT_UPDATE_TIME> TYPE FAC_OPP_S_NEXT_UPDATE_TIME.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FAC_OPP_S_NEXT_UPDATE_TIME.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FAC_OPP_S_NEXT_UPDATE_TIME
  INTO TABLE IT_FAC_OPP_S_NEXT_UPDATE_TIME.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FAC_OPP_S_NEXT_UPDATE_TIME
*  INTO TABLE @DATA(IT_FAC_OPP_S_NEXT_UPDATE_TIME2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FAC_OPP_S_NEXT_UPDATE_TIME INDEX 1 INTO DATA(WA_FAC_OPP_S_NEXT_UPDATE_TIME2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FAC_OPP_S_NEXT_UPDATE_TIME ASSIGNING <FAC_OPP_S_NEXT_UPDATE_TIME>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FAC_OPP_S_NEXT_UPDATE_TIME>-JOB_TYPE = 1.
<FAC_OPP_S_NEXT_UPDATE_TIME>-OPVAR = 1.
<FAC_OPP_S_NEXT_UPDATE_TIME>-MKOAR = 1.
<FAC_OPP_S_NEXT_UPDATE_TIME>-BKONT = 1.
<FAC_OPP_S_NEXT_UPDATE_TIME>-FRYE1_NEXT = 1.
ENDLOOP.

LOOP AT IT_FAC_OPP_S_NEXT_UPDATE_TIME INTO WA_FAC_OPP_S_NEXT_UPDATE_TIME.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FAC_OPP_S_NEXT_UPDATE_TIME-FRPE1_NEXT, sy-vline,
WA_FAC_OPP_S_NEXT_UPDATE_TIME-TOYE1_NEXT, sy-vline,
WA_FAC_OPP_S_NEXT_UPDATE_TIME-TOPE1_NEXT, sy-vline,
WA_FAC_OPP_S_NEXT_UPDATE_TIME-FRYE2_NEXT, sy-vline,
WA_FAC_OPP_S_NEXT_UPDATE_TIME-FRPE2_NEXT, sy-vline,
WA_FAC_OPP_S_NEXT_UPDATE_TIME-TOYE2_NEXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FAC_OPP_S_NEXT_UPDATE_TIME you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FAC_OPP_S_NEXT_UPDATE_TIME TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FAC_OPP_S_NEXT_UPDATE_TIME INTO WA_FAC_OPP_S_NEXT_UPDATE_TIME. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field BKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FAC_OPP_S_NEXT_UPDATE_TIME-BKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_OPP_S_NEXT_UPDATE_TIME-BKONT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FAC_OPP_S_NEXT_UPDATE_TIME_STR,
JOB_TYPE TYPE STRING,
OPVAR TYPE STRING,
MKOAR TYPE STRING,
BKONT TYPE STRING,
FRYE1_NEXT TYPE STRING,
FRPE1_NEXT TYPE STRING,
TOYE1_NEXT TYPE STRING,
TOPE1_NEXT TYPE STRING,
FRYE2_NEXT TYPE STRING,
FRPE2_NEXT TYPE STRING,
TOYE2_NEXT TYPE STRING,
TOPE2_NEXT TYPE STRING,
FRYE3_NEXT TYPE STRING,
FRPE3_NEXT TYPE STRING,
TOYE3_NEXT TYPE STRING,
TOPE3_NEXT TYPE STRING,
PERIODIC_ACTION TYPE STRING,
JOB_RUN_TIME TYPE STRING,
FLAG_KEEP_AUTH_GROUP TYPE STRING,
FLAG_RESET_AUTH_GROUP TYPE STRING,
FLAG_CHANGE_AUTH_GROUP TYPE STRING,
AUTH_GROUP TYPE STRING,
IND_AUTH_GROUP TYPE STRING,END OF T_EKKO_STR. DATA: WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-JOB_TYPE sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-OPVAR sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-MKOAR sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-BKONT sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-FRYE1_NEXT sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-FRPE1_NEXT sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-TOYE1_NEXT sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-TOPE1_NEXT sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-FRYE2_NEXT sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-FRPE2_NEXT sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-TOYE2_NEXT sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-TOPE2_NEXT sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-FRYE3_NEXT sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-FRPE3_NEXT sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-TOYE3_NEXT sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-TOPE3_NEXT sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-PERIODIC_ACTION sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-JOB_RUN_TIME sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-FLAG_KEEP_AUTH_GROUP sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-FLAG_RESET_AUTH_GROUP sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-FLAG_CHANGE_AUTH_GROUP sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-AUTH_GROUP sy-vline
WA_FAC_OPP_S_NEXT_UPDATE_TIME_STR-IND_AUTH_GROUP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.