ABAP Select data from SAP table FAAV_ANEP1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FAAV_ANEP1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FAAV_ANEP1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FAAV_ANEP1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FAAV_ANEP1 TYPE STANDARD TABLE OF FAAV_ANEP1,
      WA_FAAV_ANEP1 TYPE FAAV_ANEP1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FAAV_ANEP1> TYPE FAAV_ANEP1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FAAV_ANEP1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FAAV_ANEP1
  INTO TABLE IT_FAAV_ANEP1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FAAV_ANEP1
*  INTO TABLE @DATA(IT_FAAV_ANEP12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FAAV_ANEP1 INDEX 1 INTO DATA(WA_FAAV_ANEP12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FAAV_ANEP1 ASSIGNING <FAAV_ANEP1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FAAV_ANEP1>-MANDT = 1.
<FAAV_ANEP1>-BUKRS = 1.
<FAAV_ANEP1>-ANLN1 = 1.
<FAAV_ANEP1>-ANLN2 = 1.
<FAAV_ANEP1>-GJAHR = 1.
ENDLOOP.

LOOP AT IT_FAAV_ANEP1 INTO WA_FAAV_ANEP1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FAAV_ANEP1-LNRAN, sy-vline,
WA_FAAV_ANEP1-AFABE, sy-vline,
WA_FAAV_ANEP1-ZUCOD, sy-vline,
WA_FAAV_ANEP1-BELNR, sy-vline,
WA_FAAV_ANEP1-BUZEI, sy-vline,
WA_FAAV_ANEP1-BZDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FAAV_ANEP1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FAAV_ANEP1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FAAV_ANEP1 INTO WA_FAAV_ANEP1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ANLN1 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FAAV_ANEP1-ANLN1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAAV_ANEP1-ANLN1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANLN2 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FAAV_ANEP1-ANLN2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAAV_ANEP1-ANLN2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FAAV_ANEP1-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAAV_ANEP1-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FAAV_ANEP1-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAAV_ANEP1-BELNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FAAV_ANEP1_STR,
MANDT TYPE STRING,
BUKRS TYPE STRING,
ANLN1 TYPE STRING,
ANLN2 TYPE STRING,
GJAHR TYPE STRING,
LNRAN TYPE STRING,
AFABE TYPE STRING,
ZUCOD TYPE STRING,
BELNR TYPE STRING,
BUZEI TYPE STRING,
BZDAT TYPE STRING,
BWASL TYPE STRING,
SLALITTYPE TYPE STRING,
MOVCAT TYPE STRING,
LNSAN TYPE STRING,
AUGLN TYPE STRING,
HSL TYPE STRING,
KSL TYPE STRING,
OSL TYPE STRING,
VSL TYPE STRING,
BSL TYPE STRING,
CSL TYPE STRING,
DSL TYPE STRING,
ESL TYPE STRING,
FSL TYPE STRING,
GSL TYPE STRING,END OF T_EKKO_STR. DATA: WA_FAAV_ANEP1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FAAV_ANEP1_STR-MANDT sy-vline
WA_FAAV_ANEP1_STR-BUKRS sy-vline
WA_FAAV_ANEP1_STR-ANLN1 sy-vline
WA_FAAV_ANEP1_STR-ANLN2 sy-vline
WA_FAAV_ANEP1_STR-GJAHR sy-vline
WA_FAAV_ANEP1_STR-LNRAN sy-vline
WA_FAAV_ANEP1_STR-AFABE sy-vline
WA_FAAV_ANEP1_STR-ZUCOD sy-vline
WA_FAAV_ANEP1_STR-BELNR sy-vline
WA_FAAV_ANEP1_STR-BUZEI sy-vline
WA_FAAV_ANEP1_STR-BZDAT sy-vline
WA_FAAV_ANEP1_STR-BWASL sy-vline
WA_FAAV_ANEP1_STR-SLALITTYPE sy-vline
WA_FAAV_ANEP1_STR-MOVCAT sy-vline
WA_FAAV_ANEP1_STR-LNSAN sy-vline
WA_FAAV_ANEP1_STR-AUGLN sy-vline
WA_FAAV_ANEP1_STR-HSL sy-vline
WA_FAAV_ANEP1_STR-KSL sy-vline
WA_FAAV_ANEP1_STR-OSL sy-vline
WA_FAAV_ANEP1_STR-VSL sy-vline
WA_FAAV_ANEP1_STR-BSL sy-vline
WA_FAAV_ANEP1_STR-CSL sy-vline
WA_FAAV_ANEP1_STR-DSL sy-vline
WA_FAAV_ANEP1_STR-ESL sy-vline
WA_FAAV_ANEP1_STR-FSL sy-vline
WA_FAAV_ANEP1_STR-GSL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.