ABAP Select data from SAP table FAA_EE_S_CALCDATA_DATA into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FAA_EE_S_CALCDATA_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FAA_EE_S_CALCDATA_DATA. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FAA_EE_S_CALCDATA_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FAA_EE_S_CALCDATA_DATA TYPE STANDARD TABLE OF FAA_EE_S_CALCDATA_DATA, WA_FAA_EE_S_CALCDATA_DATA TYPE FAA_EE_S_CALCDATA_DATA, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FAA_EE_S_CALCDATA_DATA> TYPE FAA_EE_S_CALCDATA_DATA. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FAA_EE_S_CALCDATA_DATA. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FAA_EE_S_CALCDATA_DATA INTO TABLE IT_FAA_EE_S_CALCDATA_DATA. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FAA_EE_S_CALCDATA_DATA * INTO TABLE @DATA(IT_FAA_EE_S_CALCDATA_DATA2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FAA_EE_S_CALCDATA_DATA INDEX 1 INTO DATA(WA_FAA_EE_S_CALCDATA_DATA2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FAA_EE_S_CALCDATA_DATA ASSIGNING <FAA_EE_S_CALCDATA_DATA>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FAA_EE_S_CALCDATA_DATA>-PERFACTOR = 1.
<FAA_EE_S_CALCDATA_DATA>-PERCENT = 1.
<FAA_EE_S_CALCDATA_DATA>-BASEVALUE = 1.
<FAA_EE_S_CALCDATA_DATA>-BASEVAL_PREV = 1.
<FAA_EE_S_CALCDATA_DATA>-BASE_ADD = 1.
ENDLOOP. LOOP AT IT_FAA_EE_S_CALCDATA_DATA INTO WA_FAA_EE_S_CALCDATA_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FAA_EE_S_CALCDATA_DATA-BASE_ADD_PREV, sy-vline,
WA_FAA_EE_S_CALCDATA_DATA-MINVALUE, sy-vline,
WA_FAA_EE_S_CALCDATA_DATA-MINVAL_PREV, sy-vline,
WA_FAA_EE_S_CALCDATA_DATA-MINVAL_PERC_USED, sy-vline,
WA_FAA_EE_S_CALCDATA_DATA-NO_MINVAL, sy-vline,
WA_FAA_EE_S_CALCDATA_DATA-NETVALUE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FAA_EE_S_CALCDATA_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FAA_EE_S_CALCDATA_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FAA_EE_S_CALCDATA_DATA INTO WA_FAA_EE_S_CALCDATA_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FAA_EE_S_CALCDATA_DATA_STR,
PERFACTOR TYPE STRING,
PERCENT TYPE STRING,
BASEVALUE TYPE STRING,
BASEVAL_PREV TYPE STRING,
BASE_ADD TYPE STRING,
BASE_ADD_PREV TYPE STRING,
MINVALUE TYPE STRING,
MINVAL_PREV TYPE STRING,
MINVAL_PERC_USED TYPE STRING,
NO_MINVAL TYPE STRING,
NETVALUE TYPE STRING,
NETVAL_PREV TYPE STRING,
SUM_APC TYPE STRING,
SUM_APC_PREV TYPE STRING,
AMOUNT TYPE STRING,
AMOUNT_PREV TYPE STRING,
AM_ADD TYPE STRING,
AM_ADD_PREV TYPE STRING,
SIGN TYPE STRING,
AMOUNT_REDUCED TYPE STRING,
PERSEG_REDUCED TYPE STRING,
AMOUNT_SKIPPED TYPE STRING,END OF T_EKKO_STR. DATA: WA_FAA_EE_S_CALCDATA_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FAA_EE_S_CALCDATA_DATA_STR-PERFACTOR sy-vline
WA_FAA_EE_S_CALCDATA_DATA_STR-PERCENT sy-vline
WA_FAA_EE_S_CALCDATA_DATA_STR-BASEVALUE sy-vline
WA_FAA_EE_S_CALCDATA_DATA_STR-BASEVAL_PREV sy-vline
WA_FAA_EE_S_CALCDATA_DATA_STR-BASE_ADD sy-vline
WA_FAA_EE_S_CALCDATA_DATA_STR-BASE_ADD_PREV sy-vline
WA_FAA_EE_S_CALCDATA_DATA_STR-MINVALUE sy-vline
WA_FAA_EE_S_CALCDATA_DATA_STR-MINVAL_PREV sy-vline
WA_FAA_EE_S_CALCDATA_DATA_STR-MINVAL_PERC_USED sy-vline
WA_FAA_EE_S_CALCDATA_DATA_STR-NO_MINVAL sy-vline
WA_FAA_EE_S_CALCDATA_DATA_STR-NETVALUE sy-vline
WA_FAA_EE_S_CALCDATA_DATA_STR-NETVAL_PREV sy-vline
WA_FAA_EE_S_CALCDATA_DATA_STR-SUM_APC sy-vline
WA_FAA_EE_S_CALCDATA_DATA_STR-SUM_APC_PREV sy-vline
WA_FAA_EE_S_CALCDATA_DATA_STR-AMOUNT sy-vline
WA_FAA_EE_S_CALCDATA_DATA_STR-AMOUNT_PREV sy-vline
WA_FAA_EE_S_CALCDATA_DATA_STR-AM_ADD sy-vline
WA_FAA_EE_S_CALCDATA_DATA_STR-AM_ADD_PREV sy-vline
WA_FAA_EE_S_CALCDATA_DATA_STR-SIGN sy-vline
WA_FAA_EE_S_CALCDATA_DATA_STR-AMOUNT_REDUCED sy-vline
WA_FAA_EE_S_CALCDATA_DATA_STR-PERSEG_REDUCED sy-vline
WA_FAA_EE_S_CALCDATA_DATA_STR-AMOUNT_SKIPPED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.