ABAP Select data from SAP table FAA_DC_S_PROCESS_CONTROL_DATA into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FAA_DC_S_PROCESS_CONTROL_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FAA_DC_S_PROCESS_CONTROL_DATA. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FAA_DC_S_PROCESS_CONTROL_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FAA_DC_S_PROCESS_CONTROL_DATA TYPE STANDARD TABLE OF FAA_DC_S_PROCESS_CONTROL_DATA, WA_FAA_DC_S_PROCESS_CONTROL_DATA TYPE FAA_DC_S_PROCESS_CONTROL_DATA, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FAA_DC_S_PROCESS_CONTROL_DATA> TYPE FAA_DC_S_PROCESS_CONTROL_DATA. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FAA_DC_S_PROCESS_CONTROL_DATA. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FAA_DC_S_PROCESS_CONTROL_DATA INTO TABLE IT_FAA_DC_S_PROCESS_CONTROL_DATA. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FAA_DC_S_PROCESS_CONTROL_DATA * INTO TABLE @DATA(IT_FAA_DC_S_PROCESS_CONTROL_DATA2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FAA_DC_S_PROCESS_CONTROL_DATA INDEX 1 INTO DATA(WA_FAA_DC_S_PROCESS_CONTROL_DATA2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FAA_DC_S_PROCESS_CONTROL_DATA ASSIGNING <FAA_DC_S_PROCESS_CONTROL_DATA>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FAA_DC_S_PROCESS_CONTROL_DATA>-COMP_CODE = 1.
<FAA_DC_S_PROCESS_CONTROL_DATA>-LEDGER_GROUP = 1.
<FAA_DC_S_PROCESS_CONTROL_DATA>-COUNTRY = 1.
<FAA_DC_S_PROCESS_CONTROL_DATA>-FYEAR = 1.
<FAA_DC_S_PROCESS_CONTROL_DATA>-FIRST_OPEN_FYEAR = 1.
ENDLOOP. LOOP AT IT_FAA_DC_S_PROCESS_CONTROL_DATA INTO WA_FAA_DC_S_PROCESS_CONTROL_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FAA_DC_S_PROCESS_CONTROL_DATA-LAST_OPEN_FYEAR, sy-vline,
WA_FAA_DC_S_PROCESS_CONTROL_DATA-FIRST_DAY_IN_FYR, sy-vline,
WA_FAA_DC_S_PROCESS_CONTROL_DATA-LAST_DAY_IN_FYR, sy-vline,
WA_FAA_DC_S_PROCESS_CONTROL_DATA-PROCESS, sy-vline,
WA_FAA_DC_S_PROCESS_CONTROL_DATA-STEP, sy-vline,
WA_FAA_DC_S_PROCESS_CONTROL_DATA-SUBPROCESS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FAA_DC_S_PROCESS_CONTROL_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FAA_DC_S_PROCESS_CONTROL_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FAA_DC_S_PROCESS_CONTROL_DATA INTO WA_FAA_DC_S_PROCESS_CONTROL_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit GJAHR, internal->external for field FYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FAA_DC_S_PROCESS_CONTROL_DATA-FYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAA_DC_S_PROCESS_CONTROL_DATA-FYEAR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit GJAHR, internal->external for field FIRST_OPEN_FYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FAA_DC_S_PROCESS_CONTROL_DATA-FIRST_OPEN_FYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAA_DC_S_PROCESS_CONTROL_DATA-FIRST_OPEN_FYEAR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit GJAHR, internal->external for field LAST_OPEN_FYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FAA_DC_S_PROCESS_CONTROL_DATA-LAST_OPEN_FYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAA_DC_S_PROCESS_CONTROL_DATA-LAST_OPEN_FYEAR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FAA_DC_S_PROCESS_CONTROL_DATA_STR,
COMP_CODE TYPE STRING,
LEDGER_GROUP TYPE STRING,
COUNTRY TYPE STRING,
FYEAR TYPE STRING,
FIRST_OPEN_FYEAR TYPE STRING,
LAST_OPEN_FYEAR TYPE STRING,
FIRST_DAY_IN_FYR TYPE STRING,
LAST_DAY_IN_FYR TYPE STRING,
PROCESS TYPE STRING,
STEP TYPE STRING,
SUBPROCESS TYPE STRING,
PERIOD_OFFSET TYPE STRING,
SPLIT_ON_BADI TYPE STRING,
CO_ON_NBV TYPE STRING,
CO_ON_DEPR TYPE STRING,
CO_NO_CO_YR_SET TYPE STRING,
CO_COUNTRY_BADI TYPE STRING,
CO_CUSTOMER_BADI TYPE STRING,
LEADOBJ_REF TYPE STRING,END OF T_EKKO_STR. DATA: WA_FAA_DC_S_PROCESS_CONTROL_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FAA_DC_S_PROCESS_CONTROL_DATA_STR-COMP_CODE sy-vline
WA_FAA_DC_S_PROCESS_CONTROL_DATA_STR-LEDGER_GROUP sy-vline
WA_FAA_DC_S_PROCESS_CONTROL_DATA_STR-COUNTRY sy-vline
WA_FAA_DC_S_PROCESS_CONTROL_DATA_STR-FYEAR sy-vline
WA_FAA_DC_S_PROCESS_CONTROL_DATA_STR-FIRST_OPEN_FYEAR sy-vline
WA_FAA_DC_S_PROCESS_CONTROL_DATA_STR-LAST_OPEN_FYEAR sy-vline
WA_FAA_DC_S_PROCESS_CONTROL_DATA_STR-FIRST_DAY_IN_FYR sy-vline
WA_FAA_DC_S_PROCESS_CONTROL_DATA_STR-LAST_DAY_IN_FYR sy-vline
WA_FAA_DC_S_PROCESS_CONTROL_DATA_STR-PROCESS sy-vline
WA_FAA_DC_S_PROCESS_CONTROL_DATA_STR-STEP sy-vline
WA_FAA_DC_S_PROCESS_CONTROL_DATA_STR-SUBPROCESS sy-vline
WA_FAA_DC_S_PROCESS_CONTROL_DATA_STR-PERIOD_OFFSET sy-vline
WA_FAA_DC_S_PROCESS_CONTROL_DATA_STR-SPLIT_ON_BADI sy-vline
WA_FAA_DC_S_PROCESS_CONTROL_DATA_STR-CO_ON_NBV sy-vline
WA_FAA_DC_S_PROCESS_CONTROL_DATA_STR-CO_ON_DEPR sy-vline
WA_FAA_DC_S_PROCESS_CONTROL_DATA_STR-CO_NO_CO_YR_SET sy-vline
WA_FAA_DC_S_PROCESS_CONTROL_DATA_STR-CO_COUNTRY_BADI sy-vline
WA_FAA_DC_S_PROCESS_CONTROL_DATA_STR-CO_CUSTOMER_BADI sy-vline
WA_FAA_DC_S_PROCESS_CONTROL_DATA_STR-LEADOBJ_REF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.