ABAP Select data from SAP table EWFTRANS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EWFTRANS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EWFTRANS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EWFTRANS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EWFTRANS TYPE STANDARD TABLE OF EWFTRANS,
      WA_EWFTRANS TYPE EWFTRANS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EWFTRANS> TYPE EWFTRANS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EWFTRANS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EWFTRANS
  INTO TABLE IT_EWFTRANS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EWFTRANS
*  INTO TABLE @DATA(IT_EWFTRANS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EWFTRANS INDEX 1 INTO DATA(WA_EWFTRANS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EWFTRANS ASSIGNING <EWFTRANS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EWFTRANS>-MANDT = 1.
<EWFTRANS>-ACTSTAT = 1.
<EWFTRANS>-CONFIG = 1.
<EWFTRANS>-CALLID = 1.
<EWFTRANS>-TRATYPE = 1.
ENDLOOP.

LOOP AT IT_EWFTRANS INTO WA_EWFTRANS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EWFTRANS-DELEMENT, sy-vline,
WA_EWFTRANS-PRIORITY, sy-vline,
WA_EWFTRANS-DCOMPONENT, sy-vline,
WA_EWFTRANS-ELEMTYPE, sy-vline,
WA_EWFTRANS-DREFTYPE, sy-vline,
WA_EWFTRANS-DOBJTYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EWFTRANS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EWFTRANS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EWFTRANS INTO WA_EWFTRANS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field DLOGICALSYSTEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWFTRANS-DLOGICALSYSTEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWFTRANS-DLOGICALSYSTEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SLOGICALSYSTEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWFTRANS-SLOGICALSYSTEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWFTRANS-SLOGICALSYSTEM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EWFTRANS_STR,
MANDT TYPE STRING,
ACTSTAT TYPE STRING,
CONFIG TYPE STRING,
CALLID TYPE STRING,
TRATYPE TYPE STRING,
DELEMENT TYPE STRING,
PRIORITY TYPE STRING,
DCOMPONENT TYPE STRING,
ELEMTYPE TYPE STRING,
DREFTYPE TYPE STRING,
DOBJTYPE TYPE STRING,
DREFSTRUCT TYPE STRING,
DREFFIELD TYPE STRING,
DTABELEM TYPE STRING,
DOBLIG TYPE STRING,
DCOMPOBLIG TYPE STRING,
SELEMENT TYPE STRING,
SCOMPONENT TYPE STRING,
SREFTYPE TYPE STRING,
SOBJTYPE TYPE STRING,
SREFSTRUCT TYPE STRING,
SREFFIELD TYPE STRING,
STABELEM TYPE STRING,
SLITERAL TYPE STRING,
DLOGICALSYSTEM TYPE STRING,
SLOGICALSYSTEM TYPE STRING,
NOCOMP TYPE STRING,
EX_DELEM_T TYPE STRING,
EX_PRIO TYPE STRING,
EX_ICONTEXT TYPE STRING,
EX_DCOMP_T TYPE STRING,
EX_SOURCE TYPE STRING,
IM_DELEM_T TYPE STRING,
IM_PRIO TYPE STRING,
IM_ICONTEXT TYPE STRING,
IM_DCOMP_T TYPE STRING,
IM_SOURCE TYPE STRING,END OF T_EKKO_STR. DATA: WA_EWFTRANS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EWFTRANS_STR-MANDT sy-vline
WA_EWFTRANS_STR-ACTSTAT sy-vline
WA_EWFTRANS_STR-CONFIG sy-vline
WA_EWFTRANS_STR-CALLID sy-vline
WA_EWFTRANS_STR-TRATYPE sy-vline
WA_EWFTRANS_STR-DELEMENT sy-vline
WA_EWFTRANS_STR-PRIORITY sy-vline
WA_EWFTRANS_STR-DCOMPONENT sy-vline
WA_EWFTRANS_STR-ELEMTYPE sy-vline
WA_EWFTRANS_STR-DREFTYPE sy-vline
WA_EWFTRANS_STR-DOBJTYPE sy-vline
WA_EWFTRANS_STR-DREFSTRUCT sy-vline
WA_EWFTRANS_STR-DREFFIELD sy-vline
WA_EWFTRANS_STR-DTABELEM sy-vline
WA_EWFTRANS_STR-DOBLIG sy-vline
WA_EWFTRANS_STR-DCOMPOBLIG sy-vline
WA_EWFTRANS_STR-SELEMENT sy-vline
WA_EWFTRANS_STR-SCOMPONENT sy-vline
WA_EWFTRANS_STR-SREFTYPE sy-vline
WA_EWFTRANS_STR-SOBJTYPE sy-vline
WA_EWFTRANS_STR-SREFSTRUCT sy-vline
WA_EWFTRANS_STR-SREFFIELD sy-vline
WA_EWFTRANS_STR-STABELEM sy-vline
WA_EWFTRANS_STR-SLITERAL sy-vline
WA_EWFTRANS_STR-DLOGICALSYSTEM sy-vline
WA_EWFTRANS_STR-SLOGICALSYSTEM sy-vline
WA_EWFTRANS_STR-NOCOMP sy-vline
WA_EWFTRANS_STR-EX_DELEM_T sy-vline
WA_EWFTRANS_STR-EX_PRIO sy-vline
WA_EWFTRANS_STR-EX_ICONTEXT sy-vline
WA_EWFTRANS_STR-EX_DCOMP_T sy-vline
WA_EWFTRANS_STR-EX_SOURCE sy-vline
WA_EWFTRANS_STR-IM_DELEM_T sy-vline
WA_EWFTRANS_STR-IM_PRIO sy-vline
WA_EWFTRANS_STR-IM_ICONTEXT sy-vline
WA_EWFTRANS_STR-IM_DCOMP_T sy-vline
WA_EWFTRANS_STR-IM_SOURCE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.