ABAP Select data from SAP table EWAOBJ into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EWAOBJ table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EWAOBJ. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EWAOBJ table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EWAOBJ TYPE STANDARD TABLE OF EWAOBJ,
      WA_EWAOBJ TYPE EWAOBJ,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EWAOBJ> TYPE EWAOBJ.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EWAOBJ.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EWAOBJ
  INTO TABLE IT_EWAOBJ.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EWAOBJ
*  INTO TABLE @DATA(IT_EWAOBJ2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EWAOBJ INDEX 1 INTO DATA(WA_EWAOBJ2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EWAOBJ ASSIGNING <EWAOBJ>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EWAOBJ>-MANDT = 1.
<EWAOBJ>-OBJNR = 1.
<EWAOBJ>-OBKNR = 1.
<EWAOBJ>-OBZAE = 1.
<EWAOBJ>-ANLAGE = 1.
ENDLOOP.

LOOP AT IT_EWAOBJ INTO WA_EWAOBJ.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EWAOBJ-OPERAND, sy-vline,
WA_EWAOBJ-OPLFDNR, sy-vline,
WA_EWAOBJ-SERVLOC, sy-vline,
WA_EWAOBJ-MATNR, sy-vline,
WA_EWAOBJ-EQUNR, sy-vline,
WA_EWAOBJ-ADRNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EWAOBJ you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EWAOBJ TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EWAOBJ INTO WA_EWAOBJ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field OBJNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWAOBJ-OBJNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAOBJ-OBJNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANLAGE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWAOBJ-ANLAGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAOBJ-ANLAGE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field SERVLOC CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_EWAOBJ-SERVLOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAOBJ-SERVLOC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EWAOBJ-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAOBJ-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWAOBJ-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAOBJ-EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ADRNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWAOBJ-ADRNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAOBJ-ADRNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field WASTE_TYPE CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EWAOBJ-WASTE_TYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAOBJ-WASTE_TYPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field BEH_TYPE CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EWAOBJ-BEH_TYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAOBJ-BEH_TYPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ROUTE_MAIN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWAOBJ-ROUTE_MAIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAOBJ-ROUTE_MAIN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DEVGRP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWAOBJ-DEVGRP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAOBJ-DEVGRP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ROB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWAOBJ-ROB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAOBJ-ROB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OUTL_CON CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWAOBJ-OUTL_CON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAOBJ-OUTL_CON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WDPLANT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWAOBJ-WDPLANT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAOBJ-WDPLANT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field IBASE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWAOBJ-IBASE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAOBJ-IBASE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EHS_PARTNER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWAOBJ-EHS_PARTNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAOBJ-EHS_PARTNER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INTAPPNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWAOBJ-INTAPPNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAOBJ-INTAPPNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field APPNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWAOBJ-APPNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAOBJ-APPNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MNAMQIN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EWAOBJ-MNAMQIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAOBJ-MNAMQIN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TRANSPORTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWAOBJ-TRANSPORTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAOBJ-TRANSPORTER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DISPOSER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWAOBJ-DISPOSER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAOBJ-DISPOSER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNWAKEY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWAOBJ-RECNWAKEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAOBJ-RECNWAKEY.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EWAOBJ_STR,
MANDT TYPE STRING,
OBJNR TYPE STRING,
OBKNR TYPE STRING,
OBZAE TYPE STRING,
ANLAGE TYPE STRING,
OPERAND TYPE STRING,
OPLFDNR TYPE STRING,
SERVLOC TYPE STRING,
MATNR TYPE STRING,
EQUNR TYPE STRING,
ADRNR TYPE STRING,
CHANGEABLE TYPE STRING,
PRODUCT_AREA TYPE STRING,
WASTE_TYPE TYPE STRING,
BEH_TYPE TYPE STRING,
ROUTE_MAIN TYPE STRING,
LOGIKNR TYPE STRING,
DEVGRP TYPE STRING,
KOMPFAKT TYPE STRING,
ROB TYPE STRING,
WINTERLEVEL TYPE STRING,
REGPOLIT TYPE STRING,
COUNTRY TYPE STRING,
OUTL_CON TYPE STRING,
WDPLANT TYPE STRING,
WASTE_WERKS TYPE STRING,
WASTE_LGORT TYPE STRING,
IBASE TYPE STRING,
EHS_PARTNER TYPE STRING,
INTAPPNO TYPE STRING,
APPNO TYPE STRING,
RECN TYPE STRING,
WAKEYIDE TYPE STRING,
WAKEYCATLG TYPE STRING,
MNAMIN TYPE STRING,
MNAMQIN TYPE STRING,
MNINO_UNS TYPE STRING,
MNINO_BGS TYPE STRING,
TRANSPORTER TYPE STRING,
DISPOSER TYPE STRING,
RECNWAKEY TYPE STRING,
E_WERKS TYPE STRING,
E_LGORT TYPE STRING,
ERDAT TYPE STRING,
ERNAM TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
BEGRU TYPE STRING,
LOEVM TYPE STRING,END OF T_EKKO_STR. DATA: WA_EWAOBJ_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EWAOBJ_STR-MANDT sy-vline
WA_EWAOBJ_STR-OBJNR sy-vline
WA_EWAOBJ_STR-OBKNR sy-vline
WA_EWAOBJ_STR-OBZAE sy-vline
WA_EWAOBJ_STR-ANLAGE sy-vline
WA_EWAOBJ_STR-OPERAND sy-vline
WA_EWAOBJ_STR-OPLFDNR sy-vline
WA_EWAOBJ_STR-SERVLOC sy-vline
WA_EWAOBJ_STR-MATNR sy-vline
WA_EWAOBJ_STR-EQUNR sy-vline
WA_EWAOBJ_STR-ADRNR sy-vline
WA_EWAOBJ_STR-CHANGEABLE sy-vline
WA_EWAOBJ_STR-PRODUCT_AREA sy-vline
WA_EWAOBJ_STR-WASTE_TYPE sy-vline
WA_EWAOBJ_STR-BEH_TYPE sy-vline
WA_EWAOBJ_STR-ROUTE_MAIN sy-vline
WA_EWAOBJ_STR-LOGIKNR sy-vline
WA_EWAOBJ_STR-DEVGRP sy-vline
WA_EWAOBJ_STR-KOMPFAKT sy-vline
WA_EWAOBJ_STR-ROB sy-vline
WA_EWAOBJ_STR-WINTERLEVEL sy-vline
WA_EWAOBJ_STR-REGPOLIT sy-vline
WA_EWAOBJ_STR-COUNTRY sy-vline
WA_EWAOBJ_STR-OUTL_CON sy-vline
WA_EWAOBJ_STR-WDPLANT sy-vline
WA_EWAOBJ_STR-WASTE_WERKS sy-vline
WA_EWAOBJ_STR-WASTE_LGORT sy-vline
WA_EWAOBJ_STR-IBASE sy-vline
WA_EWAOBJ_STR-EHS_PARTNER sy-vline
WA_EWAOBJ_STR-INTAPPNO sy-vline
WA_EWAOBJ_STR-APPNO sy-vline
WA_EWAOBJ_STR-RECN sy-vline
WA_EWAOBJ_STR-WAKEYIDE sy-vline
WA_EWAOBJ_STR-WAKEYCATLG sy-vline
WA_EWAOBJ_STR-MNAMIN sy-vline
WA_EWAOBJ_STR-MNAMQIN sy-vline
WA_EWAOBJ_STR-MNINO_UNS sy-vline
WA_EWAOBJ_STR-MNINO_BGS sy-vline
WA_EWAOBJ_STR-TRANSPORTER sy-vline
WA_EWAOBJ_STR-DISPOSER sy-vline
WA_EWAOBJ_STR-RECNWAKEY sy-vline
WA_EWAOBJ_STR-E_WERKS sy-vline
WA_EWAOBJ_STR-E_LGORT sy-vline
WA_EWAOBJ_STR-ERDAT sy-vline
WA_EWAOBJ_STR-ERNAM sy-vline
WA_EWAOBJ_STR-AEDAT sy-vline
WA_EWAOBJ_STR-AENAM sy-vline
WA_EWAOBJ_STR-BEGRU sy-vline
WA_EWAOBJ_STR-LOEVM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.