ABAP Select data from SAP table EWAEL_DELVRYBAN_STRUCT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP EWAEL_DELVRYBAN_STRUCT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EWAEL_DELVRYBAN_STRUCT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the EWAEL_DELVRYBAN_STRUCT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_EWAEL_DELVRYBAN_STRUCT TYPE STANDARD TABLE OF EWAEL_DELVRYBAN_STRUCT, WA_EWAEL_DELVRYBAN_STRUCT TYPE EWAEL_DELVRYBAN_STRUCT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <EWAEL_DELVRYBAN_STRUCT> TYPE EWAEL_DELVRYBAN_STRUCT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_EWAEL_DELVRYBAN_STRUCT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM EWAEL_DELVRYBAN_STRUCT INTO TABLE IT_EWAEL_DELVRYBAN_STRUCT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM EWAEL_DELVRYBAN_STRUCT * INTO TABLE @DATA(IT_EWAEL_DELVRYBAN_STRUCT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_EWAEL_DELVRYBAN_STRUCT INDEX 1 INTO DATA(WA_EWAEL_DELVRYBAN_STRUCT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_EWAEL_DELVRYBAN_STRUCT ASSIGNING <EWAEL_DELVRYBAN_STRUCT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<EWAEL_DELVRYBAN_STRUCT>-WASTE = 1.
<EWAEL_DELVRYBAN_STRUCT>-VSTELLE = 1.
<EWAEL_DELVRYBAN_STRUCT>-SERVLOC = 1.
<EWAEL_DELVRYBAN_STRUCT>-SAMPLENR = 1.
<EWAEL_DELVRYBAN_STRUCT>-CREATED = 1.
ENDLOOP. LOOP AT IT_EWAEL_DELVRYBAN_STRUCT INTO WA_EWAEL_DELVRYBAN_STRUCT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_EWAEL_DELVRYBAN_STRUCT-ACTIVATED, sy-vline,
WA_EWAEL_DELVRYBAN_STRUCT-DEACTIVATED, sy-vline,
WA_EWAEL_DELVRYBAN_STRUCT-DESCRIPTION, sy-vline,
WA_EWAEL_DELVRYBAN_STRUCT-CREATED_TIME, sy-vline,
WA_EWAEL_DELVRYBAN_STRUCT-ACTIVATED_TIME, sy-vline,
WA_EWAEL_DELVRYBAN_STRUCT-DEACTIVATED_TIME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EWAEL_DELVRYBAN_STRUCT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EWAEL_DELVRYBAN_STRUCT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EWAEL_DELVRYBAN_STRUCT INTO WA_EWAEL_DELVRYBAN_STRUCT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit MATN1, internal->external for field WASTE CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EWAEL_DELVRYBAN_STRUCT-WASTE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAEL_DELVRYBAN_STRUCT-WASTE.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VSTELLE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWAEL_DELVRYBAN_STRUCT-VSTELLE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAEL_DELVRYBAN_STRUCT-VSTELLE.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TPLNR, internal->external for field SERVLOC CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_EWAEL_DELVRYBAN_STRUCT-SERVLOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAEL_DELVRYBAN_STRUCT-SERVLOC.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SAMPLENR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWAEL_DELVRYBAN_STRUCT-SAMPLENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWAEL_DELVRYBAN_STRUCT-SAMPLENR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EWAEL_DELVRYBAN_STRUCT_STR,
WASTE TYPE STRING,
VSTELLE TYPE STRING,
SERVLOC TYPE STRING,
SAMPLENR TYPE STRING,
CREATED TYPE STRING,
ACTIVATED TYPE STRING,
DEACTIVATED TYPE STRING,
DESCRIPTION TYPE STRING,
CREATED_TIME TYPE STRING,
ACTIVATED_TIME TYPE STRING,
DEACTIVATED_TIME TYPE STRING,END OF T_EKKO_STR. DATA: WA_EWAEL_DELVRYBAN_STRUCT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EWAEL_DELVRYBAN_STRUCT_STR-WASTE sy-vline
WA_EWAEL_DELVRYBAN_STRUCT_STR-VSTELLE sy-vline
WA_EWAEL_DELVRYBAN_STRUCT_STR-SERVLOC sy-vline
WA_EWAEL_DELVRYBAN_STRUCT_STR-SAMPLENR sy-vline
WA_EWAEL_DELVRYBAN_STRUCT_STR-CREATED sy-vline
WA_EWAEL_DELVRYBAN_STRUCT_STR-ACTIVATED sy-vline
WA_EWAEL_DELVRYBAN_STRUCT_STR-DEACTIVATED sy-vline
WA_EWAEL_DELVRYBAN_STRUCT_STR-DESCRIPTION sy-vline
WA_EWAEL_DELVRYBAN_STRUCT_STR-CREATED_TIME sy-vline
WA_EWAEL_DELVRYBAN_STRUCT_STR-ACTIVATED_TIME sy-vline
WA_EWAEL_DELVRYBAN_STRUCT_STR-DEACTIVATED_TIME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.