ABAP Select data from SAP table EUE_EHAU_NODE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EUE_EHAU_NODE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EUE_EHAU_NODE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EUE_EHAU_NODE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EUE_EHAU_NODE TYPE STANDARD TABLE OF EUE_EHAU_NODE,
      WA_EUE_EHAU_NODE TYPE EUE_EHAU_NODE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EUE_EHAU_NODE> TYPE EUE_EHAU_NODE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EUE_EHAU_NODE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EUE_EHAU_NODE
  INTO TABLE IT_EUE_EHAU_NODE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EUE_EHAU_NODE
*  INTO TABLE @DATA(IT_EUE_EHAU_NODE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EUE_EHAU_NODE INDEX 1 INTO DATA(WA_EUE_EHAU_NODE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EUE_EHAU_NODE ASSIGNING <EUE_EHAU_NODE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EUE_EHAU_NODE>-NODE = 1.
<EUE_EHAU_NODE>-EHAU = 1.
<EUE_EHAU_NODE>-MANDT = 1.
<EUE_EHAU_NODE>-HAUS = 1.
<EUE_EHAU_NODE>-SPRAS = 1.
ENDLOOP.

LOOP AT IT_EUE_EHAU_NODE INTO WA_EUE_EHAU_NODE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EUE_EHAU_NODE-PLTXT, sy-vline,
WA_EUE_EHAU_NODE-KZLTX, sy-vline,
WA_EUE_EHAU_NODE-TPLKZ, sy-vline,
WA_EUE_EHAU_NODE-FLTYP, sy-vline,
WA_EUE_EHAU_NODE-TPLMA, sy-vline,
WA_EUE_EHAU_NODE-DATAB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EUE_EHAU_NODE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EUE_EHAU_NODE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EUE_EHAU_NODE INTO WA_EUE_EHAU_NODE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TPLNR, internal->external for field HAUS CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_EUE_EHAU_NODE-HAUS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EUE_EHAU_NODE-HAUS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_EUE_EHAU_NODE-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EUE_EHAU_NODE-SPRAS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLMA CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_EUE_EHAU_NODE-TPLMA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EUE_EHAU_NODE-TPLMA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ADDRNUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EUE_EHAU_NODE-ADDRNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EUE_EHAU_NODE-ADDRNUMBER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EUE_EHAU_NODE_STR,
NODE TYPE STRING,
EHAU TYPE STRING,
MANDT TYPE STRING,
HAUS TYPE STRING,
SPRAS TYPE STRING,
PLTXT TYPE STRING,
KZLTX TYPE STRING,
TPLKZ TYPE STRING,
FLTYP TYPE STRING,
TPLMA TYPE STRING,
DATAB TYPE STRING,
BEGRU TYPE STRING,
EINZLI TYPE STRING,
IWERK TYPE STRING,
IWERKI TYPE STRING,
POSNR TYPE STRING,
ISTYP TYPE STRING,
PREMS TYPE STRING,
EQFNR TYPE STRING,
SWERK TYPE STRING,
SWERKI TYPE STRING,
BUKRS TYPE STRING,
BUKRSI TYPE STRING,
ADDRNUMBER TYPE STRING,
ADRNRI TYPE STRING,
LVORM TYPE STRING,
ILOAN TYPE STRING,
IEQUI TYPE STRING,
IEQUII TYPE STRING,
COUNC TYPE STRING,
REGIOGROUP TYPE STRING,
REGPOLIT TYPE STRING,
REGIOGROUP_PERM TYPE STRING,
OBJNR TYPE STRING,
ERDAT TYPE STRING,
ERNAM TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
CRM_GUID TYPE STRING,
STRNO TYPE STRING,
EVBS TYPE STRING,END OF T_EKKO_STR. DATA: WA_EUE_EHAU_NODE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EUE_EHAU_NODE_STR-NODE sy-vline
WA_EUE_EHAU_NODE_STR-EHAU sy-vline
WA_EUE_EHAU_NODE_STR-MANDT sy-vline
WA_EUE_EHAU_NODE_STR-HAUS sy-vline
WA_EUE_EHAU_NODE_STR-SPRAS sy-vline
WA_EUE_EHAU_NODE_STR-PLTXT sy-vline
WA_EUE_EHAU_NODE_STR-KZLTX sy-vline
WA_EUE_EHAU_NODE_STR-TPLKZ sy-vline
WA_EUE_EHAU_NODE_STR-FLTYP sy-vline
WA_EUE_EHAU_NODE_STR-TPLMA sy-vline
WA_EUE_EHAU_NODE_STR-DATAB sy-vline
WA_EUE_EHAU_NODE_STR-BEGRU sy-vline
WA_EUE_EHAU_NODE_STR-EINZLI sy-vline
WA_EUE_EHAU_NODE_STR-IWERK sy-vline
WA_EUE_EHAU_NODE_STR-IWERKI sy-vline
WA_EUE_EHAU_NODE_STR-POSNR sy-vline
WA_EUE_EHAU_NODE_STR-ISTYP sy-vline
WA_EUE_EHAU_NODE_STR-PREMS sy-vline
WA_EUE_EHAU_NODE_STR-EQFNR sy-vline
WA_EUE_EHAU_NODE_STR-SWERK sy-vline
WA_EUE_EHAU_NODE_STR-SWERKI sy-vline
WA_EUE_EHAU_NODE_STR-BUKRS sy-vline
WA_EUE_EHAU_NODE_STR-BUKRSI sy-vline
WA_EUE_EHAU_NODE_STR-ADDRNUMBER sy-vline
WA_EUE_EHAU_NODE_STR-ADRNRI sy-vline
WA_EUE_EHAU_NODE_STR-LVORM sy-vline
WA_EUE_EHAU_NODE_STR-ILOAN sy-vline
WA_EUE_EHAU_NODE_STR-IEQUI sy-vline
WA_EUE_EHAU_NODE_STR-IEQUII sy-vline
WA_EUE_EHAU_NODE_STR-COUNC sy-vline
WA_EUE_EHAU_NODE_STR-REGIOGROUP sy-vline
WA_EUE_EHAU_NODE_STR-REGPOLIT sy-vline
WA_EUE_EHAU_NODE_STR-REGIOGROUP_PERM sy-vline
WA_EUE_EHAU_NODE_STR-OBJNR sy-vline
WA_EUE_EHAU_NODE_STR-ERDAT sy-vline
WA_EUE_EHAU_NODE_STR-ERNAM sy-vline
WA_EUE_EHAU_NODE_STR-AEDAT sy-vline
WA_EUE_EHAU_NODE_STR-AENAM sy-vline
WA_EUE_EHAU_NODE_STR-CRM_GUID sy-vline
WA_EUE_EHAU_NODE_STR-STRNO sy-vline
WA_EUE_EHAU_NODE_STR-EVBS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.