ABAP Select data from SAP table ETWS_SECURE_OUT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ETWS_SECURE_OUT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ETWS_SECURE_OUT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ETWS_SECURE_OUT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ETWS_SECURE_OUT TYPE STANDARD TABLE OF ETWS_SECURE_OUT,
      WA_ETWS_SECURE_OUT TYPE ETWS_SECURE_OUT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ETWS_SECURE_OUT> TYPE ETWS_SECURE_OUT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ETWS_SECURE_OUT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ETWS_SECURE_OUT
  INTO TABLE IT_ETWS_SECURE_OUT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ETWS_SECURE_OUT
*  INTO TABLE @DATA(IT_ETWS_SECURE_OUT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ETWS_SECURE_OUT INDEX 1 INTO DATA(WA_ETWS_SECURE_OUT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ETWS_SECURE_OUT ASSIGNING <ETWS_SECURE_OUT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ETWS_SECURE_OUT>-HTTP_DEST = 1.
<ETWS_SECURE_OUT>-TYPE = 1.
<ETWS_SECURE_OUT>-CPSW = 1.
<ETWS_SECURE_OUT>-LUSER = 1.
<ETWS_SECURE_OUT>-LDATE = 1.
ENDLOOP.

LOOP AT IT_ETWS_SECURE_OUT INTO WA_ETWS_SECURE_OUT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ETWS_SECURE_OUT-LTIME, sy-vline,
WA_ETWS_SECURE_OUT-HTTP_CLIENT, sy-vline,
WA_ETWS_SECURE_OUT-HTTP_USER, sy-vline,
WA_ETWS_SECURE_OUT-USED, sy-vline,
WA_ETWS_SECURE_OUT-DEST_READ, sy-vline,
WA_ETWS_SECURE_OUT-ACTION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ETWS_SECURE_OUT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ETWS_SECURE_OUT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ETWS_SECURE_OUT INTO WA_ETWS_SECURE_OUT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ETWS_SECURE_OUT_STR,
HTTP_DEST TYPE STRING,
TYPE TYPE STRING,
CPSW TYPE STRING,
LUSER TYPE STRING,
LDATE TYPE STRING,
LTIME TYPE STRING,
HTTP_CLIENT TYPE STRING,
HTTP_USER TYPE STRING,
USED TYPE STRING,
DEST_READ TYPE STRING,
ACTION TYPE STRING,
PSW TYPE STRING,
MARKE TYPE STRING,
HTTP_BUTTON TYPE STRING,
HTTP_BUTTON_DEL TYPE STRING,END OF T_EKKO_STR. DATA: WA_ETWS_SECURE_OUT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ETWS_SECURE_OUT_STR-HTTP_DEST sy-vline
WA_ETWS_SECURE_OUT_STR-TYPE sy-vline
WA_ETWS_SECURE_OUT_STR-CPSW sy-vline
WA_ETWS_SECURE_OUT_STR-LUSER sy-vline
WA_ETWS_SECURE_OUT_STR-LDATE sy-vline
WA_ETWS_SECURE_OUT_STR-LTIME sy-vline
WA_ETWS_SECURE_OUT_STR-HTTP_CLIENT sy-vline
WA_ETWS_SECURE_OUT_STR-HTTP_USER sy-vline
WA_ETWS_SECURE_OUT_STR-USED sy-vline
WA_ETWS_SECURE_OUT_STR-DEST_READ sy-vline
WA_ETWS_SECURE_OUT_STR-ACTION sy-vline
WA_ETWS_SECURE_OUT_STR-PSW sy-vline
WA_ETWS_SECURE_OUT_STR-MARKE sy-vline
WA_ETWS_SECURE_OUT_STR-HTTP_BUTTON sy-vline
WA_ETWS_SECURE_OUT_STR-HTTP_BUTTON_DEL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.