ABAP Select data from SAP table ETOUEXCEPTRESP_OBJECT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ETOUEXCEPTRESP_OBJECT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ETOUEXCEPTRESP_OBJECT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ETOUEXCEPTRESP_OBJECT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ETOUEXCEPTRESP_OBJECT TYPE STANDARD TABLE OF ETOUEXCEPTRESP_OBJECT,
WA_ETOUEXCEPTRESP_OBJECT TYPE ETOUEXCEPTRESP_OBJECT,
GD_STR TYPE STRING.
DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.
FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ETOUEXCEPTRESP_OBJECT> TYPE ETOUEXCEPTRESP_OBJECT.
*Process all fields in table header/work area as string values
PERFORM process_as_string_field_values CHANGING wa_ETOUEXCEPTRESP_OBJECT.
SELECT *
*restrict ABAP select to first 10 rows
UP TO 10 ROWS
FROM ETOUEXCEPTRESP_OBJECT
INTO TABLE IT_ETOUEXCEPTRESP_OBJECT.
*Select data and declare internal table using in-line method @DATA
*SELECT *
* FROM ETOUEXCEPTRESP_OBJECT
* INTO TABLE @DATA(IT_ETOUEXCEPTRESP_OBJECT2).
*--Further methods of using ABAP code to select data from SAP database tables
*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ETOUEXCEPTRESP_OBJECT INDEX 1 INTO DATA(WA_ETOUEXCEPTRESP_OBJECT2).
*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ETOUEXCEPTRESP_OBJECT ASSIGNING <ETOUEXCEPTRESP_OBJECT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer<ETOUEXCEPTRESP_OBJECT>-CONTROL = 1.
<ETOUEXCEPTRESP_OBJECT>-GRID_CONTROLS = 1.
<ETOUEXCEPTRESP_OBJECT>-GRID_CONTAINER = 1.
<ETOUEXCEPTRESP_OBJECT>-GRID = 1.
<ETOUEXCEPTRESP_OBJECT>-REFRESH_GRID = 1.
ENDLOOP. LOOP AT IT_ETOUEXCEPTRESP_OBJECT INTO WA_ETOUEXCEPTRESP_OBJECT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ETOUEXCEPTRESP_OBJECT-LAST_CONTAINER, sy-vline,
WA_ETOUEXCEPTRESP_OBJECT-WMODE, sy-vline,
WA_ETOUEXCEPTRESP_OBJECT-OPEN_WMODE, sy-vline,
WA_ETOUEXCEPTRESP_OBJECT-UPD_ONLINE, sy-vline,
WA_ETOUEXCEPTRESP_OBJECT-NO_DIALOG, sy-vline,
WA_ETOUEXCEPTRESP_OBJECT-NUM_RANGE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ETOUEXCEPTRESP_OBJECT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ETOUEXCEPTRESP_OBJECT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ETOUEXCEPTRESP_OBJECT INTO WA_ETOUEXCEPTRESP_OBJECT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ETOUEXCEPTRESP_OBJECT_STR,
CONTROL TYPE STRING,
GRID_CONTROLS TYPE STRING,
GRID_CONTAINER TYPE STRING,
GRID TYPE STRING,
REFRESH_GRID TYPE STRING,
LAST_CONTAINER TYPE STRING,
WMODE TYPE STRING,
OPEN_WMODE TYPE STRING,
UPD_ONLINE TYPE STRING,
NO_DIALOG TYPE STRING,
NUM_RANGE TYPE STRING,
NO_CHANGE TYPE STRING,
NO_OTHER TYPE STRING,
NO_EVENT TYPE STRING,
NO_STATISTIC TYPE STRING,
NO_CHANGE_DOC TYPE STRING,
CALLED_BY_IDOC TYPE STRING,
PROPRICE TYPE STRING,
INPERR TYPE STRING,
ENQ_DONE TYPE STRING,
CURFIELD TYPE STRING,
CURLINE TYPE STRING,
CURDYNNR TYPE STRING,
SETCURFIELD TYPE STRING,
SETCURLINE TYPE STRING,
SETCURDYNNR TYPE STRING,
TEXT_CHANGED TYPE STRING,
EXTINTKZ TYPE STRING,
EXIT_TYPE TYPE STRING,
FULLSCREEN TYPE STRING,
SAVE_OKCODE TYPE STRING,
TEILOBJ TYPE STRING,
S_FUBA TYPE STRING,
INPUT_FIELD_OFF TYPE STRING,
NOFULLSCREEN TYPE STRING,
DB_UPDATE TYPE STRING,
CHANGEFLAG TYPE STRING,
WA_ADR_DONE TYPE STRING,
EXCEPTRESP_INSTANCE_DB TYPE STRING,
OBJ_PUBLIC TYPE STRING,
SUB_REPID TYPE STRING,
SUB_DYNNR TYPE STRING,
SUBSL_REPID TYPE STRING,
SUBSL_DYNNR TYPE STRING,
SCREEN TYPE STRING,
ALV_GRID TYPE STRING,
DIALOG TYPE STRING,
EXCEPTIONID TYPE STRING,
EXCEPTIONEXTID TYPE STRING,
EXCEPTIONTXT TYPE STRING,
DATEFROM TYPE STRING,
TIMEFROM TYPE STRING,
DATETO TYPE STRING,
TIMETO TYPE STRING,
EXCEPTIONPROGRAMID TYPE STRING,
EXCEPTIONPROGRAMTXT TYPE STRING,
EXCEPTIONPROGTIMEZONE TYPE STRING,
EXCEPTIONPROGTIMEZONETXT TYPE STRING,
HOTSPOT_PROGRAM TYPE STRING,
DATA TYPE STRING,
INSTANCE_LIST TYPE STRING,
SEL_INSTANCE TYPE STRING,END OF T_EKKO_STR. DATA: WA_ETOUEXCEPTRESP_OBJECT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-CONTROL sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-GRID_CONTROLS sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-GRID_CONTAINER sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-GRID sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-REFRESH_GRID sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-LAST_CONTAINER sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-WMODE sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-OPEN_WMODE sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-UPD_ONLINE sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-NO_DIALOG sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-NUM_RANGE sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-NO_CHANGE sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-NO_OTHER sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-NO_EVENT sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-NO_STATISTIC sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-NO_CHANGE_DOC sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-CALLED_BY_IDOC sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-PROPRICE sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-INPERR sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-ENQ_DONE sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-CURFIELD sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-CURLINE sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-CURDYNNR sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-SETCURFIELD sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-SETCURLINE sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-SETCURDYNNR sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-TEXT_CHANGED sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-EXTINTKZ sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-EXIT_TYPE sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-FULLSCREEN sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-SAVE_OKCODE sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-TEILOBJ sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-S_FUBA sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-INPUT_FIELD_OFF sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-NOFULLSCREEN sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-DB_UPDATE sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-CHANGEFLAG sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-WA_ADR_DONE sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-EXCEPTRESP_INSTANCE_DB sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-OBJ_PUBLIC sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-SUB_REPID sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-SUB_DYNNR sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-SUBSL_REPID sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-SUBSL_DYNNR sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-SCREEN sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-ALV_GRID sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-DIALOG sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-EXCEPTIONID sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-EXCEPTIONEXTID sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-EXCEPTIONTXT sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-DATEFROM sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-TIMEFROM sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-DATETO sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-TIMETO sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-EXCEPTIONPROGRAMID sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-EXCEPTIONPROGRAMTXT sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-EXCEPTIONPROGTIMEZONE sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-EXCEPTIONPROGTIMEZONETXT sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-HOTSPOT_PROGRAM sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-DATA sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-INSTANCE_LIST sy-vline
WA_ETOUEXCEPTRESP_OBJECT_STR-SEL_INSTANCE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.
