ABAP Select data from SAP table ETOUEXCEPTRESP_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ETOUEXCEPTRESP_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ETOUEXCEPTRESP_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ETOUEXCEPTRESP_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ETOUEXCEPTRESP_DATA TYPE STANDARD TABLE OF ETOUEXCEPTRESP_DATA,
      WA_ETOUEXCEPTRESP_DATA TYPE ETOUEXCEPTRESP_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ETOUEXCEPTRESP_DATA> TYPE ETOUEXCEPTRESP_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ETOUEXCEPTRESP_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ETOUEXCEPTRESP_DATA
  INTO TABLE IT_ETOUEXCEPTRESP_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ETOUEXCEPTRESP_DATA
*  INTO TABLE @DATA(IT_ETOUEXCEPTRESP_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ETOUEXCEPTRESP_DATA INDEX 1 INTO DATA(WA_ETOUEXCEPTRESP_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ETOUEXCEPTRESP_DATA ASSIGNING <ETOUEXCEPTRESP_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ETOUEXCEPTRESP_DATA>-CONTRACT = 1.
<ETOUEXCEPTRESP_DATA>-DIVISION = 1.
<ETOUEXCEPTRESP_DATA>-INSTALLATION = 1.
<ETOUEXCEPTRESP_DATA>-DEVICE = 1.
<ETOUEXCEPTRESP_DATA>-EQUNR = 1.
ENDLOOP.

LOOP AT IT_ETOUEXCEPTRESP_DATA INTO WA_ETOUEXCEPTRESP_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ETOUEXCEPTRESP_DATA-REGISTER, sy-vline,
WA_ETOUEXCEPTRESP_DATA-LOGIKZW, sy-vline,
WA_ETOUEXCEPTRESP_DATA-EXCEPTIONID, sy-vline,
WA_ETOUEXCEPTRESP_DATA-EXCEPTIONEXTID, sy-vline,
WA_ETOUEXCEPTRESP_DATA-EXCEPTIONTXT, sy-vline,
WA_ETOUEXCEPTRESP_DATA-DATEFROM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ETOUEXCEPTRESP_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ETOUEXCEPTRESP_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ETOUEXCEPTRESP_DATA INTO WA_ETOUEXCEPTRESP_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CONTRACT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ETOUEXCEPTRESP_DATA-CONTRACT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ETOUEXCEPTRESP_DATA-CONTRACT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSTALLATION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ETOUEXCEPTRESP_DATA-INSTALLATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ETOUEXCEPTRESP_DATA-INSTALLATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field DEVICE CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_ETOUEXCEPTRESP_DATA-DEVICE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ETOUEXCEPTRESP_DATA-DEVICE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ETOUEXCEPTRESP_DATA-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ETOUEXCEPTRESP_DATA-EQUNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ETOUEXCEPTRESP_DATA_STR,
CONTRACT TYPE STRING,
DIVISION TYPE STRING,
INSTALLATION TYPE STRING,
DEVICE TYPE STRING,
EQUNR TYPE STRING,
REGISTER TYPE STRING,
LOGIKZW TYPE STRING,
EXCEPTIONID TYPE STRING,
EXCEPTIONEXTID TYPE STRING,
EXCEPTIONTXT TYPE STRING,
DATEFROM TYPE STRING,
TIMEFROM TYPE STRING,
DATETO TYPE STRING,
TIMETO TYPE STRING,
EXCEPTIONPROGRAMID TYPE STRING,
EXCEPTIONPROGRAMTXT TYPE STRING,
EXCEPTIONSOURCE TYPE STRING,
CR_DATE TYPE STRING,
CR_TIME TYPE STRING,
CR_NAME TYPE STRING,
CH_DATE TYPE STRING,
CH_TIME TYPE STRING,
CH_NAME TYPE STRING,
EXCEPTRESP_CATEGORY TYPE STRING,
ARCHIVED TYPE STRING,END OF T_EKKO_STR. DATA: WA_ETOUEXCEPTRESP_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-CONTRACT sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-DIVISION sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-INSTALLATION sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-DEVICE sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-EQUNR sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-REGISTER sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-LOGIKZW sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-EXCEPTIONID sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-EXCEPTIONEXTID sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-EXCEPTIONTXT sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-DATEFROM sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-TIMEFROM sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-DATETO sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-TIMETO sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-EXCEPTIONPROGRAMID sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-EXCEPTIONPROGRAMTXT sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-EXCEPTIONSOURCE sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-CR_DATE sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-CR_TIME sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-CR_NAME sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-CH_DATE sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-CH_TIME sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-CH_NAME sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-EXCEPTRESP_CATEGORY sy-vline
WA_ETOUEXCEPTRESP_DATA_STR-ARCHIVED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.