ABAP Select data from SAP table ETIMESERSREPLRQ_APPLDATA_OUT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ETIMESERSREPLRQ_APPLDATA_OUT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ETIMESERSREPLRQ_APPLDATA_OUT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ETIMESERSREPLRQ_APPLDATA_OUT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ETIMESERSREPLRQ_APPLDATA_OUT TYPE STANDARD TABLE OF ETIMESERSREPLRQ_APPLDATA_OUT,
      WA_ETIMESERSREPLRQ_APPLDATA_OUT TYPE ETIMESERSREPLRQ_APPLDATA_OUT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ETIMESERSREPLRQ_APPLDATA_OUT> TYPE ETIMESERSREPLRQ_APPLDATA_OUT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ETIMESERSREPLRQ_APPLDATA_OUT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ETIMESERSREPLRQ_APPLDATA_OUT
  INTO TABLE IT_ETIMESERSREPLRQ_APPLDATA_OUT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ETIMESERSREPLRQ_APPLDATA_OUT
*  INTO TABLE @DATA(IT_ETIMESERSREPLRQ_APPLDATA_OUT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ETIMESERSREPLRQ_APPLDATA_OUT INDEX 1 INTO DATA(WA_ETIMESERSREPLRQ_APPLDATA_OUT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ETIMESERSREPLRQ_APPLDATA_OUT ASSIGNING <ETIMESERSREPLRQ_APPLDATA_OUT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ETIMESERSREPLRQ_APPLDATA_OUT>-UUID = 1.
<ETIMESERSREPLRQ_APPLDATA_OUT>-PROFILE = 1.
<ETIMESERSREPLRQ_APPLDATA_OUT>-PROFILE_DATA = 1.
<ETIMESERSREPLRQ_APPLDATA_OUT>-SPARTE = 1.
<ETIMESERSREPLRQ_APPLDATA_OUT>-PROFTYPE = 1.
ENDLOOP.

LOOP AT IT_ETIMESERSREPLRQ_APPLDATA_OUT INTO WA_ETIMESERSREPLRQ_APPLDATA_OUT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ETIMESERSREPLRQ_APPLDATA_OUT-PROFVALCAT, sy-vline,
WA_ETIMESERSREPLRQ_APPLDATA_OUT-VALUECUM, sy-vline,
WA_ETIMESERSREPLRQ_APPLDATA_OUT-INTSIZEID, sy-vline,
WA_ETIMESERSREPLRQ_APPLDATA_OUT-MASS, sy-vline,
WA_ETIMESERSREPLRQ_APPLDATA_OUT-PROFDECIMALS, sy-vline,
WA_ETIMESERSREPLRQ_APPLDATA_OUT-SOURCE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ETIMESERSREPLRQ_APPLDATA_OUT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ETIMESERSREPLRQ_APPLDATA_OUT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ETIMESERSREPLRQ_APPLDATA_OUT INTO WA_ETIMESERSREPLRQ_APPLDATA_OUT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field MASS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ETIMESERSREPLRQ_APPLDATA_OUT-MASS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ETIMESERSREPLRQ_APPLDATA_OUT-MASS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ETIMESERSREPLRQ_APPLDATA_OUT_STR,
UUID TYPE STRING,
PROFILE TYPE STRING,
PROFILE_DATA TYPE STRING,
SPARTE TYPE STRING,
PROFTYPE TYPE STRING,
PROFVALCAT TYPE STRING,
VALUECUM TYPE STRING,
INTSIZEID TYPE STRING,
MASS TYPE STRING,
PROFDECIMALS TYPE STRING,
SOURCE TYPE STRING,
OBJNR TYPE STRING,
PROFOFFSET TYPE STRING,
CONCHECKGRP TYPE STRING,
FORWARD_ORIENTED TYPE STRING,
LASTVERSNO TYPE STRING,
DATEFROM TYPE STRING,
TIMEFROM TYPE STRING,
DATETO TYPE STRING,
TIMETO TYPE STRING,
ERDAT TYPE STRING,
ERNAM TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
BEGRU TYPE STRING,
LOEVM TYPE STRING,
WAERS TYPE STRING,
ARCH_DATEFROM TYPE STRING,
ARCH_TIMEFROM TYPE STRING,
ARCH_DATETO TYPE STRING,
ARCH_TIMETO TYPE STRING,
REF_PROFILE TYPE STRING,
REPLACEMETHODGRP TYPE STRING,
DAY_OFFSET TYPE STRING,
TIME_ZONE TYPE STRING,
SRCPROFILE TYPE STRING,
MDUS_LOCATED TYPE STRING,
TOU_BILLABLE TYPE STRING,
PROFASS_DATA TYPE STRING,
IEPROFASS TYPE STRING,
AMS TYPE STRING,END OF T_EKKO_STR. DATA: WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-UUID sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-PROFILE sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-PROFILE_DATA sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-SPARTE sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-PROFTYPE sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-PROFVALCAT sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-VALUECUM sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-INTSIZEID sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-MASS sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-PROFDECIMALS sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-SOURCE sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-OBJNR sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-PROFOFFSET sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-CONCHECKGRP sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-FORWARD_ORIENTED sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-LASTVERSNO sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-DATEFROM sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-TIMEFROM sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-DATETO sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-TIMETO sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-ERDAT sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-ERNAM sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-AEDAT sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-AENAM sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-BEGRU sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-LOEVM sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-WAERS sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-ARCH_DATEFROM sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-ARCH_TIMEFROM sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-ARCH_DATETO sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-ARCH_TIMETO sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-REF_PROFILE sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-REPLACEMETHODGRP sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-DAY_OFFSET sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-TIME_ZONE sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-SRCPROFILE sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-MDUS_LOCATED sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-TOU_BILLABLE sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-PROFASS_DATA sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-IEPROFASS sy-vline
WA_ETIMESERSREPLRQ_APPLDATA_OUT_STR-AMS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.