ABAP Select data from SAP table ETATT_PROP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ETATT_PROP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ETATT_PROP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ETATT_PROP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ETATT_PROP TYPE STANDARD TABLE OF ETATT_PROP,
      WA_ETATT_PROP TYPE ETATT_PROP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ETATT_PROP> TYPE ETATT_PROP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ETATT_PROP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ETATT_PROP
  INTO TABLE IT_ETATT_PROP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ETATT_PROP
*  INTO TABLE @DATA(IT_ETATT_PROP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ETATT_PROP INDEX 1 INTO DATA(WA_ETATT_PROP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ETATT_PROP ASSIGNING <ETATT_PROP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ETATT_PROP>-ATTACHMENT_NAME = 1.
<ETATT_PROP>-ATTACHMENT_TYPE = 1.
<ETATT_PROP>-ATTCHMNT_SUBTYPE = 1.
<ETATT_PROP>-FILE_PATH = 1.
<ETATT_PROP>-IS_DEFAULT = 1.
ENDLOOP.

LOOP AT IT_ETATT_PROP INTO WA_ETATT_PROP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ETATT_PROP-ATTACHMENT, sy-vline,
WA_ETATT_PROP-FUSER, sy-vline,
WA_ETATT_PROP-FDATE, sy-vline,
WA_ETATT_PROP-FTIME, sy-vline,
WA_ETATT_PROP-LUSER, sy-vline,
WA_ETATT_PROP-LDATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ETATT_PROP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ETATT_PROP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ETATT_PROP INTO WA_ETATT_PROP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ETATT_PROP_STR,
ATTACHMENT_NAME TYPE STRING,
ATTACHMENT_TYPE TYPE STRING,
ATTCHMNT_SUBTYPE TYPE STRING,
FILE_PATH TYPE STRING,
IS_DEFAULT TYPE STRING,
ATTACHMENT TYPE STRING,
FUSER TYPE STRING,
FDATE TYPE STRING,
FTIME TYPE STRING,
LUSER TYPE STRING,
LDATE TYPE STRING,
LTIME TYPE STRING,
FILE_SIZE TYPE STRING,
LINKED_TO TYPE STRING,
LINKED_TYPE TYPE STRING,
IS_COMPRESSED TYPE STRING,
COMP_FILESIZE TYPE STRING,END OF T_EKKO_STR. DATA: WA_ETATT_PROP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ETATT_PROP_STR-ATTACHMENT_NAME sy-vline
WA_ETATT_PROP_STR-ATTACHMENT_TYPE sy-vline
WA_ETATT_PROP_STR-ATTCHMNT_SUBTYPE sy-vline
WA_ETATT_PROP_STR-FILE_PATH sy-vline
WA_ETATT_PROP_STR-IS_DEFAULT sy-vline
WA_ETATT_PROP_STR-ATTACHMENT sy-vline
WA_ETATT_PROP_STR-FUSER sy-vline
WA_ETATT_PROP_STR-FDATE sy-vline
WA_ETATT_PROP_STR-FTIME sy-vline
WA_ETATT_PROP_STR-LUSER sy-vline
WA_ETATT_PROP_STR-LDATE sy-vline
WA_ETATT_PROP_STR-LTIME sy-vline
WA_ETATT_PROP_STR-FILE_SIZE sy-vline
WA_ETATT_PROP_STR-LINKED_TO sy-vline
WA_ETATT_PROP_STR-LINKED_TYPE sy-vline
WA_ETATT_PROP_STR-IS_COMPRESSED sy-vline
WA_ETATT_PROP_STR-COMP_FILESIZE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.