ABAP Select data from SAP table ESH_U_PSM_VNT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ESH_U_PSM_VNT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ESH_U_PSM_VNT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ESH_U_PSM_VNT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ESH_U_PSM_VNT TYPE STANDARD TABLE OF ESH_U_PSM_VNT,
      WA_ESH_U_PSM_VNT TYPE ESH_U_PSM_VNT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ESH_U_PSM_VNT> TYPE ESH_U_PSM_VNT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ESH_U_PSM_VNT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ESH_U_PSM_VNT
  INTO TABLE IT_ESH_U_PSM_VNT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ESH_U_PSM_VNT
*  INTO TABLE @DATA(IT_ESH_U_PSM_VNT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ESH_U_PSM_VNT INDEX 1 INTO DATA(WA_ESH_U_PSM_VNT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ESH_U_PSM_VNT ASSIGNING <ESH_U_PSM_VNT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ESH_U_PSM_VNT>-MANDT = 1.
<ESH_U_PSM_VNT>-PRODSTRUCVARIANTCHGSTATEINTID = 1.
<ESH_U_PSM_VNT>-PRODUCTSTRUCTURENODENAME = 1.
<ESH_U_PSM_VNT>-PRODUCTSTRUCTURENODETYPE = 1.
<ESH_U_PSM_VNT>-PRODUCTSTRUCTUREVARIANTTYPE = 1.
ENDLOOP.

LOOP AT IT_ESH_U_PSM_VNT INTO WA_ESH_U_PSM_VNT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ESH_U_PSM_VNT-CLASS, sy-vline,
WA_ESH_U_PSM_VNT-PRODUCTSTRUCTUREVARIANTNAME, sy-vline,
WA_ESH_U_PSM_VNT-MATERIAL, sy-vline,
WA_ESH_U_PSM_VNT-PRODUCTSTRUCTUREVARIANTUUID, sy-vline,
WA_ESH_U_PSM_VNT-PRODSTRUCVARIANTCHANGENUMBER, sy-vline,
ENDLOOP. *Add any further fields from structure WA_ESH_U_PSM_VNT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ESH_U_PSM_VNT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ESH_U_PSM_VNT INTO WA_ESH_U_PSM_VNT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PRODUCTSTRUCTUREVARIANTNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ESH_U_PSM_VNT-PRODUCTSTRUCTUREVARIANTNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ESH_U_PSM_VNT-PRODUCTSTRUCTUREVARIANTNAME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ESH_U_PSM_VNT-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ESH_U_PSM_VNT-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRODSTRUCVARIANTCHANGENUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ESH_U_PSM_VNT-PRODSTRUCVARIANTCHANGENUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ESH_U_PSM_VNT-PRODSTRUCVARIANTCHANGENUMBER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ESH_U_PSM_VNT_STR,
MANDT TYPE STRING,
PRODSTRUCVARIANTCHGSTATEINTID TYPE STRING,
PRODUCTSTRUCTURENODENAME TYPE STRING,
PRODUCTSTRUCTURENODETYPE TYPE STRING,
PRODUCTSTRUCTUREVARIANTTYPE TYPE STRING,
CLASS TYPE STRING,
PRODUCTSTRUCTUREVARIANTNAME TYPE STRING,
MATERIAL TYPE STRING,
PRODUCTSTRUCTUREVARIANTUUID TYPE STRING,
PRODSTRUCVARIANTCHANGENUMBER TYPE STRING,END OF T_EKKO_STR. DATA: WA_ESH_U_PSM_VNT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ESH_U_PSM_VNT_STR-MANDT sy-vline
WA_ESH_U_PSM_VNT_STR-PRODSTRUCVARIANTCHGSTATEINTID sy-vline
WA_ESH_U_PSM_VNT_STR-PRODUCTSTRUCTURENODENAME sy-vline
WA_ESH_U_PSM_VNT_STR-PRODUCTSTRUCTURENODETYPE sy-vline
WA_ESH_U_PSM_VNT_STR-PRODUCTSTRUCTUREVARIANTTYPE sy-vline
WA_ESH_U_PSM_VNT_STR-CLASS sy-vline
WA_ESH_U_PSM_VNT_STR-PRODUCTSTRUCTUREVARIANTNAME sy-vline
WA_ESH_U_PSM_VNT_STR-MATERIAL sy-vline
WA_ESH_U_PSM_VNT_STR-PRODUCTSTRUCTUREVARIANTUUID sy-vline
WA_ESH_U_PSM_VNT_STR-PRODSTRUCVARIANTCHANGENUMBER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.