ABAP Select data from SAP table ESH_U_ICMOBJECT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ESH_U_ICMOBJECT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ESH_U_ICMOBJECT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ESH_U_ICMOBJECT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ESH_U_ICMOBJECT TYPE STANDARD TABLE OF ESH_U_ICMOBJECT,
      WA_ESH_U_ICMOBJECT TYPE ESH_U_ICMOBJECT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ESH_U_ICMOBJECT> TYPE ESH_U_ICMOBJECT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ESH_U_ICMOBJECT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ESH_U_ICMOBJECT
  INTO TABLE IT_ESH_U_ICMOBJECT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ESH_U_ICMOBJECT
*  INTO TABLE @DATA(IT_ESH_U_ICMOBJECT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ESH_U_ICMOBJECT INDEX 1 INTO DATA(WA_ESH_U_ICMOBJECT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ESH_U_ICMOBJECT ASSIGNING <ESH_U_ICMOBJECT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ESH_U_ICMOBJECT>-MANDT = 1.
<ESH_U_ICMOBJECT>-INVGCSMOBJECTID = 1.
<ESH_U_ICMOBJECT>-BUSINESSUSER = 1.
<ESH_U_ICMOBJECT>-FILEDESCRIPTION = 1.
<ESH_U_ICMOBJECT>-FILENAME = 1.
ENDLOOP.

LOOP AT IT_ESH_U_ICMOBJECT INTO WA_ESH_U_ICMOBJECT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ESH_U_ICMOBJECT-FIRSTNAME, sy-vline,
WA_ESH_U_ICMOBJECT-INVGCSMCATEGORYDESC, sy-vline,
WA_ESH_U_ICMOBJECT-INVGCSMIMAGEFILEID, sy-vline,
WA_ESH_U_ICMOBJECT-INVGCSMOBJECTNAME, sy-vline,
WA_ESH_U_ICMOBJECT-INVGCSMOBJECTSECURITYLEVEL, sy-vline,
WA_ESH_U_ICMOBJECT-INVGCSMOTHERNAME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ESH_U_ICMOBJECT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ESH_U_ICMOBJECT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ESH_U_ICMOBJECT INTO WA_ESH_U_ICMOBJECT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INVGCSMPARTNERNUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ESH_U_ICMOBJECT-INVGCSMPARTNERNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ESH_U_ICMOBJECT-INVGCSMPARTNERNUMBER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ESH_U_ICMOBJECT_STR,
MANDT TYPE STRING,
INVGCSMOBJECTID TYPE STRING,
BUSINESSUSER TYPE STRING,
FILEDESCRIPTION TYPE STRING,
FILENAME TYPE STRING,
FIRSTNAME TYPE STRING,
INVGCSMCATEGORYDESC TYPE STRING,
INVGCSMIMAGEFILEID TYPE STRING,
INVGCSMOBJECTNAME TYPE STRING,
INVGCSMOBJECTSECURITYLEVEL TYPE STRING,
INVGCSMOTHERNAME TYPE STRING,
INVGCSMPARTNERNUMBER TYPE STRING,
INVGCSMSECURITYLVLDESC TYPE STRING,
LASTNAME TYPE STRING,
ORGANIZATIONBPNAME1 TYPE STRING,
ORGANIZATIONBPNAME2 TYPE STRING,
ATTACHMENT TYPE STRING,
PLAINLONGTEXT TYPE STRING,
RELATIONNOTE TYPE STRING,END OF T_EKKO_STR. DATA: WA_ESH_U_ICMOBJECT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ESH_U_ICMOBJECT_STR-MANDT sy-vline
WA_ESH_U_ICMOBJECT_STR-INVGCSMOBJECTID sy-vline
WA_ESH_U_ICMOBJECT_STR-BUSINESSUSER sy-vline
WA_ESH_U_ICMOBJECT_STR-FILEDESCRIPTION sy-vline
WA_ESH_U_ICMOBJECT_STR-FILENAME sy-vline
WA_ESH_U_ICMOBJECT_STR-FIRSTNAME sy-vline
WA_ESH_U_ICMOBJECT_STR-INVGCSMCATEGORYDESC sy-vline
WA_ESH_U_ICMOBJECT_STR-INVGCSMIMAGEFILEID sy-vline
WA_ESH_U_ICMOBJECT_STR-INVGCSMOBJECTNAME sy-vline
WA_ESH_U_ICMOBJECT_STR-INVGCSMOBJECTSECURITYLEVEL sy-vline
WA_ESH_U_ICMOBJECT_STR-INVGCSMOTHERNAME sy-vline
WA_ESH_U_ICMOBJECT_STR-INVGCSMPARTNERNUMBER sy-vline
WA_ESH_U_ICMOBJECT_STR-INVGCSMSECURITYLVLDESC sy-vline
WA_ESH_U_ICMOBJECT_STR-LASTNAME sy-vline
WA_ESH_U_ICMOBJECT_STR-ORGANIZATIONBPNAME1 sy-vline
WA_ESH_U_ICMOBJECT_STR-ORGANIZATIONBPNAME2 sy-vline
WA_ESH_U_ICMOBJECT_STR-ATTACHMENT sy-vline
WA_ESH_U_ICMOBJECT_STR-PLAINLONGTEXT sy-vline
WA_ESH_U_ICMOBJECT_STR-RELATIONNOTE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.