ABAP Select data from SAP table ESH_S_CM_ASSIS_SYS_COUP_TEXT_C into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ESH_S_CM_ASSIS_SYS_COUP_TEXT_C table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ESH_S_CM_ASSIS_SYS_COUP_TEXT_C. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ESH_S_CM_ASSIS_SYS_COUP_TEXT_C table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C TYPE STANDARD TABLE OF ESH_S_CM_ASSIS_SYS_COUP_TEXT_C,
      WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C TYPE ESH_S_CM_ASSIS_SYS_COUP_TEXT_C,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ESH_S_CM_ASSIS_SYS_COUP_TEXT_C> TYPE ESH_S_CM_ASSIS_SYS_COUP_TEXT_C.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ESH_S_CM_ASSIS_SYS_COUP_TEXT_C
  INTO TABLE IT_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ESH_S_CM_ASSIS_SYS_COUP_TEXT_C
*  INTO TABLE @DATA(IT_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C INDEX 1 INTO DATA(WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C ASSIGNING <ESH_S_CM_ASSIS_SYS_COUP_TEXT_C>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ESH_S_CM_ASSIS_SYS_COUP_TEXT_C>-CONFIRM_CANCEL = 1.
<ESH_S_CM_ASSIS_SYS_COUP_TEXT_C>-ASK_FOR_SAVE_TITLE = 1.
<ESH_S_CM_ASSIS_SYS_COUP_TEXT_C>-CONFIRM_CANCEL_MAIN = 1.
<ESH_S_CM_ASSIS_SYS_COUP_TEXT_C>-CONFIRM_CANCEL_MAIN_SEQ1 = 1.
<ESH_S_CM_ASSIS_SYS_COUP_TEXT_C>-ASK_FOR_SAVE_TITLE_MAIN = 1.
ENDLOOP.

LOOP AT IT_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C INTO WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C-ASK_FOR_DELETE_TITLE, sy-vline,
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C-CONFIRM_DELETE, sy-vline,
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C-CONFIRM_DELETE_SEQ1, sy-vline,
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C-ASK_FOR_REPAIR_TITLE, sy-vline,
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C-CONFIRM_REPAIR, sy-vline,
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C-CONFIRM_REPAIR_SEQ1, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C INTO WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C_STR,
CONFIRM_CANCEL TYPE STRING,
ASK_FOR_SAVE_TITLE TYPE STRING,
CONFIRM_CANCEL_MAIN TYPE STRING,
CONFIRM_CANCEL_MAIN_SEQ1 TYPE STRING,
ASK_FOR_SAVE_TITLE_MAIN TYPE STRING,
ASK_FOR_DELETE_TITLE TYPE STRING,
CONFIRM_DELETE TYPE STRING,
CONFIRM_DELETE_SEQ1 TYPE STRING,
ASK_FOR_REPAIR_TITLE TYPE STRING,
CONFIRM_REPAIR TYPE STRING,
CONFIRM_REPAIR_SEQ1 TYPE STRING,
CONFIRM_REPAIR_SEQ2 TYPE STRING,
CONFIRM_REPAIR_SEQ3 TYPE STRING,
ASK_FOR_EXPERT_MODE_TITLE TYPE STRING,
CONFIRM_EXPERT_MODE TYPE STRING,
CONFIRM_EXPERT_MODE_SEQ1 TYPE STRING,
ASK_FOR_EXPERT_SAVE_TITLE TYPE STRING,
CONFIRM_EXPERT_SAVE TYPE STRING,
ASK_FOR_CLOSE_TITLE TYPE STRING,
CONFIRM_CLOSE TYPE STRING,END OF T_EKKO_STR. DATA: WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C_STR-CONFIRM_CANCEL sy-vline
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C_STR-ASK_FOR_SAVE_TITLE sy-vline
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C_STR-CONFIRM_CANCEL_MAIN sy-vline
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C_STR-CONFIRM_CANCEL_MAIN_SEQ1 sy-vline
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C_STR-ASK_FOR_SAVE_TITLE_MAIN sy-vline
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C_STR-ASK_FOR_DELETE_TITLE sy-vline
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C_STR-CONFIRM_DELETE sy-vline
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C_STR-CONFIRM_DELETE_SEQ1 sy-vline
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C_STR-ASK_FOR_REPAIR_TITLE sy-vline
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C_STR-CONFIRM_REPAIR sy-vline
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C_STR-CONFIRM_REPAIR_SEQ1 sy-vline
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C_STR-CONFIRM_REPAIR_SEQ2 sy-vline
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C_STR-CONFIRM_REPAIR_SEQ3 sy-vline
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C_STR-ASK_FOR_EXPERT_MODE_TITLE sy-vline
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C_STR-CONFIRM_EXPERT_MODE sy-vline
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C_STR-CONFIRM_EXPERT_MODE_SEQ1 sy-vline
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C_STR-ASK_FOR_EXPERT_SAVE_TITLE sy-vline
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C_STR-CONFIRM_EXPERT_SAVE sy-vline
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C_STR-ASK_FOR_CLOSE_TITLE sy-vline
WA_ESH_S_CM_ASSIS_SYS_COUP_TEXT_C_STR-CONFIRM_CLOSE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.