ABAP Select data from SAP table ESD_OBJECT_DATA into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ESD_OBJECT_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ESD_OBJECT_DATA. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ESD_OBJECT_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ESD_OBJECT_DATA TYPE STANDARD TABLE OF ESD_OBJECT_DATA,
WA_ESD_OBJECT_DATA TYPE ESD_OBJECT_DATA,
GD_STR TYPE STRING.
DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.
FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ESD_OBJECT_DATA> TYPE ESD_OBJECT_DATA.
*Process all fields in table header/work area as string values
PERFORM process_as_string_field_values CHANGING wa_ESD_OBJECT_DATA.
SELECT *
*restrict ABAP select to first 10 rows
UP TO 10 ROWS
FROM ESD_OBJECT_DATA
INTO TABLE IT_ESD_OBJECT_DATA.
*Select data and declare internal table using in-line method @DATA
*SELECT *
* FROM ESD_OBJECT_DATA
* INTO TABLE @DATA(IT_ESD_OBJECT_DATA2).
*--Further methods of using ABAP code to select data from SAP database tables
*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ESD_OBJECT_DATA INDEX 1 INTO DATA(WA_ESD_OBJECT_DATA2).
*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ESD_OBJECT_DATA ASSIGNING <ESD_OBJECT_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer<ESD_OBJECT_DATA>-ESD_ID = 1.
<ESD_OBJECT_DATA>-TYPE = 1.
<ESD_OBJECT_DATA>-NAME = 1.
<ESD_OBJECT_DATA>-NAMESPACE = 1.
<ESD_OBJECT_DATA>-TECH_NAME = 1.
ENDLOOP. LOOP AT IT_ESD_OBJECT_DATA INTO WA_ESD_OBJECT_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ESD_OBJECT_DATA-DESC_SHORT, sy-vline,
WA_ESD_OBJECT_DATA-DESC_LONG, sy-vline,
WA_ESD_OBJECT_DATA-SOAP_NAMESPACE, sy-vline,
WA_ESD_OBJECT_DATA-DIRECTION, sy-vline,
WA_ESD_OBJECT_DATA-VARIANT, sy-vline,
WA_ESD_OBJECT_DATA-PATH_PREFIX, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ESD_OBJECT_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ESD_OBJECT_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ESD_OBJECT_DATA INTO WA_ESD_OBJECT_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ISOLA, internal->external for field ORIG_LANG CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_ESD_OBJECT_DATA-ORIG_LANG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ESD_OBJECT_DATA-ORIG_LANG.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ESD_OBJECT_DATA_STR,
ESD_ID TYPE STRING,
TYPE TYPE STRING,
NAME TYPE STRING,
NAMESPACE TYPE STRING,
TECH_NAME TYPE STRING,
DESC_SHORT TYPE STRING,
DESC_LONG TYPE STRING,
SOAP_NAMESPACE TYPE STRING,
DIRECTION TYPE STRING,
VARIANT TYPE STRING,
PATH_PREFIX TYPE STRING,
OPERATION TYPE STRING,
SOC_FLAG TYPE STRING,
SOC_DESC TYPE STRING,
AUTH_FLAG TYPE STRING,
AUTH_DESC TYPE STRING,
AUTH_LVL TYPE STRING,
AUTH_LVL_FLAG TYPE STRING,
TRANS_FLAG TYPE STRING,
TRANS_DESC TYPE STRING,
TRANS_LVL_FLAG TYPE STRING,
TRANS_LVL TYPE STRING,
PORTTYPENAME TYPE STRING,
ESD_ESR TYPE STRING,
ESR_TYPE TYPE STRING,
ESR_NAME TYPE STRING,
ESR_NAMESPACE TYPE STRING,
ESD_ENDPOINT TYPE STRING,
SERVICE_DEF TYPE STRING,
FUNC TYPE STRING,
FUNC_ST TYPE STRING,
PARAM TYPE STRING,
PARAM_TYPE TYPE STRING,
PARAM_TYPE_ICON TYPE STRING,
PARAM_CLASS TYPE STRING,
PARAM_FLAG_OPTIONAL TYPE STRING,
PARAM_DEFAULT_VALUE TYPE STRING,
PARAM_ST TYPE STRING,
COMP TYPE STRING,
COMP_TYPE TYPE STRING,
COMP_TYPE_ICON TYPE STRING,
COMP_CLASS TYPE STRING,
TYPE TYPE STRING,
TYPE_ICON TYPE STRING,
TYPE_CLASS TYPE STRING,
TYPE_DESC TYPE STRING,
STD_VALUE TYPE STRING,
STD_VALUE_FLAG TYPE STRING,
ABAP_CLASS TYPE STRING,
FIELD TYPE STRING,
FIELD_TYPE TYPE STRING,
NAME TYPE STRING,
REF TYPE STRING,
ESD_BO TYPE STRING,
PROV_CLASS TYPE STRING,
PROV_IF TYPE STRING,
ADAPT_CLASS TYPE STRING,
ESD_DT_ENH TYPE STRING,
NAME TYPE STRING,
NAMESPACE TYPE STRING,
ABAP_NAME TYPE STRING,
ESD_GENERAL_DATA TYPE STRING,
DEV_CLASS TYPE STRING,
ORIG_LANG TYPE STRING,
CREATED_BY TYPE STRING,
CREATION_DATE TYPE STRING,
CREATION_TIME TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGE_DATE TYPE STRING,
CHANGE_TIME TYPE STRING,
LIFE_CYCLE TYPE STRING,
LEADING_BO TYPE STRING,
SEMANTIC_VERSION TYPE STRING,
ESD_OBJECT_KEY TYPE STRING,
ESD_OBJECT_TYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_ESD_OBJECT_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ESD_OBJECT_DATA_STR-ESD_ID sy-vline
WA_ESD_OBJECT_DATA_STR-TYPE sy-vline
WA_ESD_OBJECT_DATA_STR-NAME sy-vline
WA_ESD_OBJECT_DATA_STR-NAMESPACE sy-vline
WA_ESD_OBJECT_DATA_STR-TECH_NAME sy-vline
WA_ESD_OBJECT_DATA_STR-DESC_SHORT sy-vline
WA_ESD_OBJECT_DATA_STR-DESC_LONG sy-vline
WA_ESD_OBJECT_DATA_STR-SOAP_NAMESPACE sy-vline
WA_ESD_OBJECT_DATA_STR-DIRECTION sy-vline
WA_ESD_OBJECT_DATA_STR-VARIANT sy-vline
WA_ESD_OBJECT_DATA_STR-PATH_PREFIX sy-vline
WA_ESD_OBJECT_DATA_STR-OPERATION sy-vline
WA_ESD_OBJECT_DATA_STR-SOC_FLAG sy-vline
WA_ESD_OBJECT_DATA_STR-SOC_DESC sy-vline
WA_ESD_OBJECT_DATA_STR-AUTH_FLAG sy-vline
WA_ESD_OBJECT_DATA_STR-AUTH_DESC sy-vline
WA_ESD_OBJECT_DATA_STR-AUTH_LVL sy-vline
WA_ESD_OBJECT_DATA_STR-AUTH_LVL_FLAG sy-vline
WA_ESD_OBJECT_DATA_STR-TRANS_FLAG sy-vline
WA_ESD_OBJECT_DATA_STR-TRANS_DESC sy-vline
WA_ESD_OBJECT_DATA_STR-TRANS_LVL_FLAG sy-vline
WA_ESD_OBJECT_DATA_STR-TRANS_LVL sy-vline
WA_ESD_OBJECT_DATA_STR-PORTTYPENAME sy-vline
WA_ESD_OBJECT_DATA_STR-ESD_ESR sy-vline
WA_ESD_OBJECT_DATA_STR-ESR_TYPE sy-vline
WA_ESD_OBJECT_DATA_STR-ESR_NAME sy-vline
WA_ESD_OBJECT_DATA_STR-ESR_NAMESPACE sy-vline
WA_ESD_OBJECT_DATA_STR-ESD_ENDPOINT sy-vline
WA_ESD_OBJECT_DATA_STR-SERVICE_DEF sy-vline
WA_ESD_OBJECT_DATA_STR-FUNC sy-vline
WA_ESD_OBJECT_DATA_STR-FUNC_ST sy-vline
WA_ESD_OBJECT_DATA_STR-PARAM sy-vline
WA_ESD_OBJECT_DATA_STR-PARAM_TYPE sy-vline
WA_ESD_OBJECT_DATA_STR-PARAM_TYPE_ICON sy-vline
WA_ESD_OBJECT_DATA_STR-PARAM_CLASS sy-vline
WA_ESD_OBJECT_DATA_STR-PARAM_FLAG_OPTIONAL sy-vline
WA_ESD_OBJECT_DATA_STR-PARAM_DEFAULT_VALUE sy-vline
WA_ESD_OBJECT_DATA_STR-PARAM_ST sy-vline
WA_ESD_OBJECT_DATA_STR-COMP sy-vline
WA_ESD_OBJECT_DATA_STR-COMP_TYPE sy-vline
WA_ESD_OBJECT_DATA_STR-COMP_TYPE_ICON sy-vline
WA_ESD_OBJECT_DATA_STR-COMP_CLASS sy-vline
WA_ESD_OBJECT_DATA_STR-TYPE sy-vline
WA_ESD_OBJECT_DATA_STR-TYPE_ICON sy-vline
WA_ESD_OBJECT_DATA_STR-TYPE_CLASS sy-vline
WA_ESD_OBJECT_DATA_STR-TYPE_DESC sy-vline
WA_ESD_OBJECT_DATA_STR-STD_VALUE sy-vline
WA_ESD_OBJECT_DATA_STR-STD_VALUE_FLAG sy-vline
WA_ESD_OBJECT_DATA_STR-ABAP_CLASS sy-vline
WA_ESD_OBJECT_DATA_STR-FIELD sy-vline
WA_ESD_OBJECT_DATA_STR-FIELD_TYPE sy-vline
WA_ESD_OBJECT_DATA_STR-NAME sy-vline
WA_ESD_OBJECT_DATA_STR-REF sy-vline
WA_ESD_OBJECT_DATA_STR-ESD_BO sy-vline
WA_ESD_OBJECT_DATA_STR-PROV_CLASS sy-vline
WA_ESD_OBJECT_DATA_STR-PROV_IF sy-vline
WA_ESD_OBJECT_DATA_STR-ADAPT_CLASS sy-vline
WA_ESD_OBJECT_DATA_STR-ESD_DT_ENH sy-vline
WA_ESD_OBJECT_DATA_STR-NAME sy-vline
WA_ESD_OBJECT_DATA_STR-NAMESPACE sy-vline
WA_ESD_OBJECT_DATA_STR-ABAP_NAME sy-vline
WA_ESD_OBJECT_DATA_STR-ESD_GENERAL_DATA sy-vline
WA_ESD_OBJECT_DATA_STR-DEV_CLASS sy-vline
WA_ESD_OBJECT_DATA_STR-ORIG_LANG sy-vline
WA_ESD_OBJECT_DATA_STR-CREATED_BY sy-vline
WA_ESD_OBJECT_DATA_STR-CREATION_DATE sy-vline
WA_ESD_OBJECT_DATA_STR-CREATION_TIME sy-vline
WA_ESD_OBJECT_DATA_STR-CHANGED_BY sy-vline
WA_ESD_OBJECT_DATA_STR-CHANGE_DATE sy-vline
WA_ESD_OBJECT_DATA_STR-CHANGE_TIME sy-vline
WA_ESD_OBJECT_DATA_STR-LIFE_CYCLE sy-vline
WA_ESD_OBJECT_DATA_STR-LEADING_BO sy-vline
WA_ESD_OBJECT_DATA_STR-SEMANTIC_VERSION sy-vline
WA_ESD_OBJECT_DATA_STR-ESD_OBJECT_KEY sy-vline
WA_ESD_OBJECT_DATA_STR-ESD_OBJECT_TYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.