ABAP Select data from SAP table ESD_INFO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ESD_INFO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ESD_INFO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ESD_INFO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ESD_INFO TYPE STANDARD TABLE OF ESD_INFO,
      WA_ESD_INFO TYPE ESD_INFO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ESD_INFO> TYPE ESD_INFO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ESD_INFO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ESD_INFO
  INTO TABLE IT_ESD_INFO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ESD_INFO
*  INTO TABLE @DATA(IT_ESD_INFO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ESD_INFO INDEX 1 INTO DATA(WA_ESD_INFO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ESD_INFO ASSIGNING <ESD_INFO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ESD_INFO>-DOCNUM = 1.
<ESD_INFO>-VBELN = 1.
<ESD_INFO>-VTRNR = 1.
<ESD_INFO>-IDNKD = 1.
<ESD_INFO>-LABNK = 1.
ENDLOOP.

LOOP AT IT_ESD_INFO INTO WA_ESD_INFO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ESD_INFO-TEXT, sy-vline,
WA_ESD_INFO-PARTN_AG, sy-vline,
WA_ESD_INFO-KWERK, sy-vline,
WA_ESD_INFO-DFABL, sy-vline,
WA_ESD_INFO-PARTN_LF, sy-vline,
WA_ESD_INFO-PARTN_WE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ESD_INFO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ESD_INFO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ESD_INFO INTO WA_ESD_INFO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ESD_INFO-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ESD_INFO-VBELN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ESD_INFO_STR,
DOCNUM TYPE STRING,
VBELN TYPE STRING,
VTRNR TYPE STRING,
IDNKD TYPE STRING,
LABNK TYPE STRING,
TEXT TYPE STRING,
PARTN_AG TYPE STRING,
KWERK TYPE STRING,
DFABL TYPE STRING,
PARTN_LF TYPE STRING,
PARTN_WE TYPE STRING,
BSTDK TYPE STRING,
ZEICH TYPE STRING,
BSTZD TYPE STRING,
ABRVW TYPE STRING,
KSTAT TYPE STRING,
KTEXT TYPE STRING,
ABNRA TYPE STRING,
ABNRD TYPE STRING,
KTEXT_V TYPE STRING,
USR01 TYPE STRING,
USR02 TYPE STRING,
USR03 TYPE STRING,
USR04 TYPE STRING,
USR05 TYPE STRING,
CYEFZ TYPE STRING,
CYDAT TYPE STRING,
MFLAUF TYPE STRING,
MFEIN TYPE STRING,
FFLAUF TYPE STRING,
FFEIN TYPE STRING,
ARKTX TYPE STRING,
VRKME TYPE STRING,
KLGOR TYPE STRING,
VBRST TYPE STRING,
BELNR TYPE STRING,
VEMNG TYPE STRING,
LIDTL TYPE STRING,
LIFST TYPE STRING,
KRITB TYPE STRING,
ABHOR TYPE STRING,
ABDAT TYPE STRING,
FZDIF TYPE STRING,
AKUBM TYPE STRING,
AKUEM TYPE STRING,
DESRE TYPE STRING,
ECHNO TYPE STRING,
ECHDT TYPE STRING,
ABFDE TYPE STRING,
MFADT TYPE STRING,
ABMDE TYPE STRING,
FPSDN TYPE STRING,
LABKY_TEXT TYPE STRING,
TSTKY TYPE STRING,
DOKPF TYPE STRING,
KZAUS TYPE STRING,
ABRAB TYPE STRING,
ABRBI TYPE STRING,
NULDT TYPE STRING,
TEART TYPE STRING,
SOLLFZ TYPE STRING,
SOLLDT TYPE STRING,
IDNLF TYPE STRING,
MFRFZ TYPE STRING,
POSEX TYPE STRING,
PCKAR TYPE STRING,
PCKNR TYPE STRING,
ANZPK TYPE STRING,
PCKSL TYPE STRING,
ANZAR TYPE STRING,
ETTYP_TEXT TYPE STRING,
BELDAT TYPE STRING,
BELTIM TYPE STRING,
LIKME TYPE STRING,
LIDTIM TYPE STRING,
LFIMG TYPE STRING,
BOX TYPE STRING,END OF T_EKKO_STR. DATA: WA_ESD_INFO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ESD_INFO_STR-DOCNUM sy-vline
WA_ESD_INFO_STR-VBELN sy-vline
WA_ESD_INFO_STR-VTRNR sy-vline
WA_ESD_INFO_STR-IDNKD sy-vline
WA_ESD_INFO_STR-LABNK sy-vline
WA_ESD_INFO_STR-TEXT sy-vline
WA_ESD_INFO_STR-PARTN_AG sy-vline
WA_ESD_INFO_STR-KWERK sy-vline
WA_ESD_INFO_STR-DFABL sy-vline
WA_ESD_INFO_STR-PARTN_LF sy-vline
WA_ESD_INFO_STR-PARTN_WE sy-vline
WA_ESD_INFO_STR-BSTDK sy-vline
WA_ESD_INFO_STR-ZEICH sy-vline
WA_ESD_INFO_STR-BSTZD sy-vline
WA_ESD_INFO_STR-ABRVW sy-vline
WA_ESD_INFO_STR-KSTAT sy-vline
WA_ESD_INFO_STR-KTEXT sy-vline
WA_ESD_INFO_STR-ABNRA sy-vline
WA_ESD_INFO_STR-ABNRD sy-vline
WA_ESD_INFO_STR-KTEXT_V sy-vline
WA_ESD_INFO_STR-USR01 sy-vline
WA_ESD_INFO_STR-USR02 sy-vline
WA_ESD_INFO_STR-USR03 sy-vline
WA_ESD_INFO_STR-USR04 sy-vline
WA_ESD_INFO_STR-USR05 sy-vline
WA_ESD_INFO_STR-CYEFZ sy-vline
WA_ESD_INFO_STR-CYDAT sy-vline
WA_ESD_INFO_STR-MFLAUF sy-vline
WA_ESD_INFO_STR-MFEIN sy-vline
WA_ESD_INFO_STR-FFLAUF sy-vline
WA_ESD_INFO_STR-FFEIN sy-vline
WA_ESD_INFO_STR-ARKTX sy-vline
WA_ESD_INFO_STR-VRKME sy-vline
WA_ESD_INFO_STR-KLGOR sy-vline
WA_ESD_INFO_STR-VBRST sy-vline
WA_ESD_INFO_STR-BELNR sy-vline
WA_ESD_INFO_STR-VEMNG sy-vline
WA_ESD_INFO_STR-LIDTL sy-vline
WA_ESD_INFO_STR-LIFST sy-vline
WA_ESD_INFO_STR-KRITB sy-vline
WA_ESD_INFO_STR-ABHOR sy-vline
WA_ESD_INFO_STR-ABDAT sy-vline
WA_ESD_INFO_STR-FZDIF sy-vline
WA_ESD_INFO_STR-AKUBM sy-vline
WA_ESD_INFO_STR-AKUEM sy-vline
WA_ESD_INFO_STR-DESRE sy-vline
WA_ESD_INFO_STR-ECHNO sy-vline
WA_ESD_INFO_STR-ECHDT sy-vline
WA_ESD_INFO_STR-ABFDE sy-vline
WA_ESD_INFO_STR-MFADT sy-vline
WA_ESD_INFO_STR-ABMDE sy-vline
WA_ESD_INFO_STR-FPSDN sy-vline
WA_ESD_INFO_STR-LABKY_TEXT sy-vline
WA_ESD_INFO_STR-TSTKY sy-vline
WA_ESD_INFO_STR-DOKPF sy-vline
WA_ESD_INFO_STR-KZAUS sy-vline
WA_ESD_INFO_STR-ABRAB sy-vline
WA_ESD_INFO_STR-ABRBI sy-vline
WA_ESD_INFO_STR-NULDT sy-vline
WA_ESD_INFO_STR-TEART sy-vline
WA_ESD_INFO_STR-SOLLFZ sy-vline
WA_ESD_INFO_STR-SOLLDT sy-vline
WA_ESD_INFO_STR-IDNLF sy-vline
WA_ESD_INFO_STR-MFRFZ sy-vline
WA_ESD_INFO_STR-POSEX sy-vline
WA_ESD_INFO_STR-PCKAR sy-vline
WA_ESD_INFO_STR-PCKNR sy-vline
WA_ESD_INFO_STR-ANZPK sy-vline
WA_ESD_INFO_STR-PCKSL sy-vline
WA_ESD_INFO_STR-ANZAR sy-vline
WA_ESD_INFO_STR-ETTYP_TEXT sy-vline
WA_ESD_INFO_STR-BELDAT sy-vline
WA_ESD_INFO_STR-BELTIM sy-vline
WA_ESD_INFO_STR-LIKME sy-vline
WA_ESD_INFO_STR-LIDTIM sy-vline
WA_ESD_INFO_STR-LFIMG sy-vline
WA_ESD_INFO_STR-BOX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.