ABAP Select data from SAP table ERTPRESVALUE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ERTPRESVALUE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ERTPRESVALUE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ERTPRESVALUE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ERTPRESVALUE TYPE STANDARD TABLE OF ERTPRESVALUE,
      WA_ERTPRESVALUE TYPE ERTPRESVALUE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ERTPRESVALUE> TYPE ERTPRESVALUE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ERTPRESVALUE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ERTPRESVALUE
  INTO TABLE IT_ERTPRESVALUE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ERTPRESVALUE
*  INTO TABLE @DATA(IT_ERTPRESVALUE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ERTPRESVALUE INDEX 1 INTO DATA(WA_ERTPRESVALUE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ERTPRESVALUE ASSIGNING <ERTPRESVALUE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ERTPRESVALUE>-RESULTNO = 1.
<ERTPRESVALUE>-CSNO = 1.
<ERTPRESVALUE>-NUMBER = 1.
<ERTPRESVALUE>-RESFROM_UTC = 1.
<ERTPRESVALUE>-DATEFROM = 1.
ENDLOOP.

LOOP AT IT_ERTPRESVALUE INTO WA_ERTPRESVALUE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ERTPRESVALUE-TIMEFROM, sy-vline,
WA_ERTPRESVALUE-RESFROM, sy-vline,
WA_ERTPRESVALUE-DATEFROM, sy-vline,
WA_ERTPRESVALUE-TIMEFROM, sy-vline,
WA_ERTPRESVALUE-RESTO_UTC, sy-vline,
WA_ERTPRESVALUE-DATETO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ERTPRESVALUE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ERTPRESVALUE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ERTPRESVALUE INTO WA_ERTPRESVALUE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ERTPRESVALUE_STR,
RESULTNO TYPE STRING,
CSNO TYPE STRING,
NUMBER TYPE STRING,
RESFROM_UTC TYPE STRING,
DATEFROM TYPE STRING,
TIMEFROM TYPE STRING,
RESFROM TYPE STRING,
DATEFROM TYPE STRING,
TIMEFROM TYPE STRING,
RESTO_UTC TYPE STRING,
DATETO TYPE STRING,
TIMETO TYPE STRING,
RESTO TYPE STRING,
DATETO TYPE STRING,
TIMETO TYPE STRING,
RESVALUE TYPE STRING,
RESINFO TYPE STRING,
FILLED TYPE STRING,END OF T_EKKO_STR. DATA: WA_ERTPRESVALUE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ERTPRESVALUE_STR-RESULTNO sy-vline
WA_ERTPRESVALUE_STR-CSNO sy-vline
WA_ERTPRESVALUE_STR-NUMBER sy-vline
WA_ERTPRESVALUE_STR-RESFROM_UTC sy-vline
WA_ERTPRESVALUE_STR-DATEFROM sy-vline
WA_ERTPRESVALUE_STR-TIMEFROM sy-vline
WA_ERTPRESVALUE_STR-RESFROM sy-vline
WA_ERTPRESVALUE_STR-DATEFROM sy-vline
WA_ERTPRESVALUE_STR-TIMEFROM sy-vline
WA_ERTPRESVALUE_STR-RESTO_UTC sy-vline
WA_ERTPRESVALUE_STR-DATETO sy-vline
WA_ERTPRESVALUE_STR-TIMETO sy-vline
WA_ERTPRESVALUE_STR-RESTO sy-vline
WA_ERTPRESVALUE_STR-DATETO sy-vline
WA_ERTPRESVALUE_STR-TIMETO sy-vline
WA_ERTPRESVALUE_STR-RESVALUE sy-vline
WA_ERTPRESVALUE_STR-RESINFO sy-vline
WA_ERTPRESVALUE_STR-FILLED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.