ABAP Select data from SAP table ENT6093 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ENT6093 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ENT6093. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ENT6093 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ENT6093 TYPE STANDARD TABLE OF ENT6093,
      WA_ENT6093 TYPE ENT6093,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ENT6093> TYPE ENT6093.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ENT6093.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ENT6093
  INTO TABLE IT_ENT6093.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ENT6093
*  INTO TABLE @DATA(IT_ENT60932).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ENT6093 INDEX 1 INTO DATA(WA_ENT60932).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ENT6093 ASSIGNING <ENT6093>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ENT6093>-MANDT = 1.
<ENT6093>-VKORG = 1.
<ENT6093>-VTWEG = 1.
<ENT6093>-KUNNR = 1.
<ENT6093>-MATNR = 1.
ENDLOOP.

LOOP AT IT_ENT6093 INTO WA_ENT6093.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ENT6093-ERNAM, sy-vline,
WA_ENT6093-ERDAT, sy-vline,
WA_ENT6093-SORTL, sy-vline,
WA_ENT6093-KDMAT, sy-vline,
WA_ENT6093-POSTX, sy-vline,
WA_ENT6093-LPRIO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ENT6093 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ENT6093 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ENT6093 INTO WA_ENT6093. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT6093-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT6093-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ENT6093-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT6093-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ENT6093-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT6093-MEINS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ENT6093_STR,
MANDT TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
KUNNR TYPE STRING,
MATNR TYPE STRING,
ERNAM TYPE STRING,
ERDAT TYPE STRING,
SORTL TYPE STRING,
KDMAT TYPE STRING,
POSTX TYPE STRING,
LPRIO TYPE STRING,
MINLF TYPE STRING,
MEINS TYPE STRING,
CHSPL TYPE STRING,
KZTLF TYPE STRING,
ANTLF TYPE STRING,
UNTTO TYPE STRING,
UEBTO TYPE STRING,
UEBTK TYPE STRING,END OF T_EKKO_STR. DATA: WA_ENT6093_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ENT6093_STR-MANDT sy-vline
WA_ENT6093_STR-VKORG sy-vline
WA_ENT6093_STR-VTWEG sy-vline
WA_ENT6093_STR-KUNNR sy-vline
WA_ENT6093_STR-MATNR sy-vline
WA_ENT6093_STR-ERNAM sy-vline
WA_ENT6093_STR-ERDAT sy-vline
WA_ENT6093_STR-SORTL sy-vline
WA_ENT6093_STR-KDMAT sy-vline
WA_ENT6093_STR-POSTX sy-vline
WA_ENT6093_STR-LPRIO sy-vline
WA_ENT6093_STR-MINLF sy-vline
WA_ENT6093_STR-MEINS sy-vline
WA_ENT6093_STR-CHSPL sy-vline
WA_ENT6093_STR-KZTLF sy-vline
WA_ENT6093_STR-ANTLF sy-vline
WA_ENT6093_STR-UNTTO sy-vline
WA_ENT6093_STR-UEBTO sy-vline
WA_ENT6093_STR-UEBTK sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.