ABAP Select data from SAP table ENT5831 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ENT5831 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ENT5831. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ENT5831 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ENT5831 TYPE STANDARD TABLE OF ENT5831,
      WA_ENT5831 TYPE ENT5831,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ENT5831> TYPE ENT5831.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ENT5831.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ENT5831
  INTO TABLE IT_ENT5831.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ENT5831
*  INTO TABLE @DATA(IT_ENT58312).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ENT5831 INDEX 1 INTO DATA(WA_ENT58312).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ENT5831 ASSIGNING <ENT5831>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ENT5831>-MANDT = 1.
<ENT5831>-PLNTY = 1.
<ENT5831>-PLNNR = 1.
<ENT5831>-PLNKN = 1.
<ENT5831>-ZAEHL = 1.
ENDLOOP.

LOOP AT IT_ENT5831 INTO WA_ENT5831.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ENT5831-DATUV, sy-vline,
WA_ENT5831-ANDAT, sy-vline,
WA_ENT5831-ANNAM, sy-vline,
WA_ENT5831-AEDAT, sy-vline,
WA_ENT5831-AENAM, sy-vline,
WA_ENT5831-SUMNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ENT5831 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ENT5831 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ENT5831 INTO WA_ENT5831. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT5831-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5831-PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field VORNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_ENT5831-VORNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5831-VORNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field TXTSP CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_ENT5831-TXTSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5831-TXTSP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EHOFFB CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ENT5831-EHOFFB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5831-EHOFFB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EHOFFE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ENT5831-EHOFFE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5831-EHOFFE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field USE04 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ENT5831-USE04 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5831-USE04.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field USE05 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ENT5831-USE05 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5831-USE05.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ENT5831-MEINH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5831-MEINH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DAUNE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ENT5831-DAUNE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5831-DAUNE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DAUME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ENT5831-DAUME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5831-DAUME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ARBEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ENT5831-ARBEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5831-ARBEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANFKO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT5831-ANFKO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5831-ANFKO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ENT5831_STR,
MANDT TYPE STRING,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
PLNKN TYPE STRING,
ZAEHL TYPE STRING,
DATUV TYPE STRING,
ANDAT TYPE STRING,
ANNAM TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
SUMNR TYPE STRING,
VORNR TYPE STRING,
LTXA1 TYPE STRING,
TXTSP TYPE STRING,
RSTRA TYPE STRING,
BZOFFB TYPE STRING,
OFFSTB TYPE STRING,
EHOFFB TYPE STRING,
BZOFFE TYPE STRING,
OFFSTE TYPE STRING,
EHOFFE TYPE STRING,
MLSTN TYPE STRING,
PPRIO TYPE STRING,
SLWID TYPE STRING,
USR00 TYPE STRING,
USR01 TYPE STRING,
USR02 TYPE STRING,
USR03 TYPE STRING,
USR04 TYPE STRING,
USE04 TYPE STRING,
USR05 TYPE STRING,
USE05 TYPE STRING,
USR06 TYPE STRING,
USE06 TYPE STRING,
USR07 TYPE STRING,
USE07 TYPE STRING,
USR08 TYPE STRING,
USR09 TYPE STRING,
USR10 TYPE STRING,
USR11 TYPE STRING,
FRSP TYPE STRING,
STEUS TYPE STRING,
ARBID TYPE STRING,
OBJTY TYPE STRING,
WERKS TYPE STRING,
KTSCH TYPE STRING,
MEINH TYPE STRING,
UMREN TYPE STRING,
UMREZ TYPE STRING,
BMSCH TYPE STRING,
DAUNO TYPE STRING,
DAUNE TYPE STRING,
DAUMI TYPE STRING,
DAUME TYPE STRING,
DDEHN TYPE STRING,
EINSA TYPE STRING,
EINSE TYPE STRING,
ARBEI TYPE STRING,
ARBEH TYPE STRING,
ANZZL TYPE STRING,
PRZNT TYPE STRING,
VERTL TYPE STRING,
ANFKO TYPE STRING,
ANFKOKRS TYPE STRING,
KAPAR TYPE STRING,
INDET TYPE STRING,
LARNT TYPE STRING,
KALID TYPE STRING,
VERTN TYPE STRING,END OF T_EKKO_STR. DATA: WA_ENT5831_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ENT5831_STR-MANDT sy-vline
WA_ENT5831_STR-PLNTY sy-vline
WA_ENT5831_STR-PLNNR sy-vline
WA_ENT5831_STR-PLNKN sy-vline
WA_ENT5831_STR-ZAEHL sy-vline
WA_ENT5831_STR-DATUV sy-vline
WA_ENT5831_STR-ANDAT sy-vline
WA_ENT5831_STR-ANNAM sy-vline
WA_ENT5831_STR-AEDAT sy-vline
WA_ENT5831_STR-AENAM sy-vline
WA_ENT5831_STR-SUMNR sy-vline
WA_ENT5831_STR-VORNR sy-vline
WA_ENT5831_STR-LTXA1 sy-vline
WA_ENT5831_STR-TXTSP sy-vline
WA_ENT5831_STR-RSTRA sy-vline
WA_ENT5831_STR-BZOFFB sy-vline
WA_ENT5831_STR-OFFSTB sy-vline
WA_ENT5831_STR-EHOFFB sy-vline
WA_ENT5831_STR-BZOFFE sy-vline
WA_ENT5831_STR-OFFSTE sy-vline
WA_ENT5831_STR-EHOFFE sy-vline
WA_ENT5831_STR-MLSTN sy-vline
WA_ENT5831_STR-PPRIO sy-vline
WA_ENT5831_STR-SLWID sy-vline
WA_ENT5831_STR-USR00 sy-vline
WA_ENT5831_STR-USR01 sy-vline
WA_ENT5831_STR-USR02 sy-vline
WA_ENT5831_STR-USR03 sy-vline
WA_ENT5831_STR-USR04 sy-vline
WA_ENT5831_STR-USE04 sy-vline
WA_ENT5831_STR-USR05 sy-vline
WA_ENT5831_STR-USE05 sy-vline
WA_ENT5831_STR-USR06 sy-vline
WA_ENT5831_STR-USE06 sy-vline
WA_ENT5831_STR-USR07 sy-vline
WA_ENT5831_STR-USE07 sy-vline
WA_ENT5831_STR-USR08 sy-vline
WA_ENT5831_STR-USR09 sy-vline
WA_ENT5831_STR-USR10 sy-vline
WA_ENT5831_STR-USR11 sy-vline
WA_ENT5831_STR-FRSP sy-vline
WA_ENT5831_STR-STEUS sy-vline
WA_ENT5831_STR-ARBID sy-vline
WA_ENT5831_STR-OBJTY sy-vline
WA_ENT5831_STR-WERKS sy-vline
WA_ENT5831_STR-KTSCH sy-vline
WA_ENT5831_STR-MEINH sy-vline
WA_ENT5831_STR-UMREN sy-vline
WA_ENT5831_STR-UMREZ sy-vline
WA_ENT5831_STR-BMSCH sy-vline
WA_ENT5831_STR-DAUNO sy-vline
WA_ENT5831_STR-DAUNE sy-vline
WA_ENT5831_STR-DAUMI sy-vline
WA_ENT5831_STR-DAUME sy-vline
WA_ENT5831_STR-DDEHN sy-vline
WA_ENT5831_STR-EINSA sy-vline
WA_ENT5831_STR-EINSE sy-vline
WA_ENT5831_STR-ARBEI sy-vline
WA_ENT5831_STR-ARBEH sy-vline
WA_ENT5831_STR-ANZZL sy-vline
WA_ENT5831_STR-PRZNT sy-vline
WA_ENT5831_STR-VERTL sy-vline
WA_ENT5831_STR-ANFKO sy-vline
WA_ENT5831_STR-ANFKOKRS sy-vline
WA_ENT5831_STR-KAPAR sy-vline
WA_ENT5831_STR-INDET sy-vline
WA_ENT5831_STR-LARNT sy-vline
WA_ENT5831_STR-KALID sy-vline
WA_ENT5831_STR-VERTN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.