ABAP Select data from SAP table ENT5703 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP ENT5703 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ENT5703. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the ENT5703 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_ENT5703 TYPE STANDARD TABLE OF ENT5703, WA_ENT5703 TYPE ENT5703, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <ENT5703> TYPE ENT5703. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_ENT5703. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM ENT5703 INTO TABLE IT_ENT5703. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM ENT5703 * INTO TABLE @DATA(IT_ENT57032). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_ENT5703 INDEX 1 INTO DATA(WA_ENT57032). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_ENT5703 ASSIGNING <ENT5703>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<ENT5703>-MANDT = 1.
<ENT5703>-MATNR = 1.
<ENT5703>-ZAEHL = 1.
<ENT5703>-ERSTELLER = 1.
<ENT5703>-ERSTELLDAT = 1.
ENDLOOP. LOOP AT IT_ENT5703 INTO WA_ENT5703. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_ENT5703-AENDERER, sy-vline,
WA_ENT5703-AENDERDAT, sy-vline,
WA_ENT5703-LIEFERANT, sy-vline,
WA_ENT5703-WERK, sy-vline,
WA_ENT5703-FREI_DAT, sy-vline,
WA_ENT5703-FREI_MGKZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ENT5703 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ENT5703 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ENT5703 INTO WA_ENT5703. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ENT5703-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5703-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field LIEFERANT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT5703-LIEFERANT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5703-LIEFERANT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field ME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ENT5703-ME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5703-ME.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ISOLA, internal->external for field SPRACHE CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_ENT5703-SPRACHE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5703-SPRACHE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ENT5703_STR,
MANDT TYPE STRING,
MATNR TYPE STRING,
ZAEHL TYPE STRING,
ERSTELLER TYPE STRING,
ERSTELLDAT TYPE STRING,
AENDERER TYPE STRING,
AENDERDAT TYPE STRING,
LIEFERANT TYPE STRING,
WERK TYPE STRING,
FREI_DAT TYPE STRING,
FREI_MGKZ TYPE STRING,
ME TYPE STRING,
FREI_MNG TYPE STRING,
BEST_MG TYPE STRING,
DAT_RUECK TYPE STRING,
SPERRGRUND TYPE STRING,
SPRACHE TYPE STRING,
SPERRFKT TYPE STRING,
QVVORH TYPE STRING,END OF T_EKKO_STR. DATA: WA_ENT5703_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ENT5703_STR-MANDT sy-vline
WA_ENT5703_STR-MATNR sy-vline
WA_ENT5703_STR-ZAEHL sy-vline
WA_ENT5703_STR-ERSTELLER sy-vline
WA_ENT5703_STR-ERSTELLDAT sy-vline
WA_ENT5703_STR-AENDERER sy-vline
WA_ENT5703_STR-AENDERDAT sy-vline
WA_ENT5703_STR-LIEFERANT sy-vline
WA_ENT5703_STR-WERK sy-vline
WA_ENT5703_STR-FREI_DAT sy-vline
WA_ENT5703_STR-FREI_MGKZ sy-vline
WA_ENT5703_STR-ME sy-vline
WA_ENT5703_STR-FREI_MNG sy-vline
WA_ENT5703_STR-BEST_MG sy-vline
WA_ENT5703_STR-DAT_RUECK sy-vline
WA_ENT5703_STR-SPERRGRUND sy-vline
WA_ENT5703_STR-SPRACHE sy-vline
WA_ENT5703_STR-SPERRFKT sy-vline
WA_ENT5703_STR-QVVORH sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.