ABAP Select data from SAP table ENT5002 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ENT5002 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ENT5002. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ENT5002 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ENT5002 TYPE STANDARD TABLE OF ENT5002,
      WA_ENT5002 TYPE ENT5002,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ENT5002> TYPE ENT5002.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ENT5002.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ENT5002
  INTO TABLE IT_ENT5002.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ENT5002
*  INTO TABLE @DATA(IT_ENT50022).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ENT5002 INDEX 1 INTO DATA(WA_ENT50022).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ENT5002 ASSIGNING <ENT5002>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ENT5002>-MANDT = 1.
<ENT5002>-MATNR = 1.
<ENT5002>-BADAT = 1.
<ENT5002>-MATKL = 1.
<ENT5002>-MEINS = 1.
ENDLOOP.

LOOP AT IT_ENT5002 INTO WA_ENT5002.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ENT5002-MENGE, sy-vline,
WA_ENT5002-LIFNR, sy-vline,
WA_ENT5002-WERKS, sy-vline,
WA_ENT5002-TXZ01, sy-vline,
WA_ENT5002-BSART, sy-vline,
WA_ENT5002-BVDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ENT5002 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ENT5002 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ENT5002 INTO WA_ENT5002. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ENT5002-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5002-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ENT5002-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5002-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT5002-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5002-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field EMATN CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ENT5002-EMATN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5002-EMATN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BANFN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT5002-BANFN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5002-BANFN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FLIEF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT5002-FLIEF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5002-FLIEF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field QUNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT5002-QUNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5002-QUNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KONNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT5002-KONNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5002-KONNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT5002-INFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5002-INFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT5002-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT5002-EBELN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ENT5002_STR,
MANDT TYPE STRING,
MATNR TYPE STRING,
BADAT TYPE STRING,
MATKL TYPE STRING,
MEINS TYPE STRING,
MENGE TYPE STRING,
LIFNR TYPE STRING,
WERKS TYPE STRING,
TXZ01 TYPE STRING,
BSART TYPE STRING,
BVDAT TYPE STRING,
BVDRK TYPE STRING,
AFNAM TYPE STRING,
BATOL TYPE STRING,
BEDNR TYPE STRING,
FRGDT TYPE STRING,
DISPO TYPE STRING,
ESTKZ TYPE STRING,
EKGRP TYPE STRING,
EMATN TYPE STRING,
PSTYP TYPE STRING,
FRGKZ TYPE STRING,
LOEKZ TYPE STRING,
BANFN TYPE STRING,
STATU TYPE STRING,
FRGZU TYPE STRING,
FRGST TYPE STRING,
ERNAM TYPE STRING,
ERDAT TYPE STRING,
BNFPO TYPE STRING,
LGORT TYPE STRING,
FLIEF TYPE STRING,
EKORG TYPE STRING,
QUNUM TYPE STRING,
QUPOS TYPE STRING,
SERNR TYPE STRING,
BUMNG TYPE STRING,
LPEIN TYPE STRING,
LFDAT TYPE STRING,
WEBAZ TYPE STRING,
PREIS TYPE STRING,
PEINH TYPE STRING,
KNTTP TYPE STRING,
KZVBR TYPE STRING,
WEPOS TYPE STRING,
REPOS TYPE STRING,
BSMNG TYPE STRING,
KONNR TYPE STRING,
KTPNR TYPE STRING,
INFNR TYPE STRING,
EBELN TYPE STRING,
EBELP TYPE STRING,
BWTAR TYPE STRING,
VRTKZ TYPE STRING,
TWRKZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_ENT5002_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ENT5002_STR-MANDT sy-vline
WA_ENT5002_STR-MATNR sy-vline
WA_ENT5002_STR-BADAT sy-vline
WA_ENT5002_STR-MATKL sy-vline
WA_ENT5002_STR-MEINS sy-vline
WA_ENT5002_STR-MENGE sy-vline
WA_ENT5002_STR-LIFNR sy-vline
WA_ENT5002_STR-WERKS sy-vline
WA_ENT5002_STR-TXZ01 sy-vline
WA_ENT5002_STR-BSART sy-vline
WA_ENT5002_STR-BVDAT sy-vline
WA_ENT5002_STR-BVDRK sy-vline
WA_ENT5002_STR-AFNAM sy-vline
WA_ENT5002_STR-BATOL sy-vline
WA_ENT5002_STR-BEDNR sy-vline
WA_ENT5002_STR-FRGDT sy-vline
WA_ENT5002_STR-DISPO sy-vline
WA_ENT5002_STR-ESTKZ sy-vline
WA_ENT5002_STR-EKGRP sy-vline
WA_ENT5002_STR-EMATN sy-vline
WA_ENT5002_STR-PSTYP sy-vline
WA_ENT5002_STR-FRGKZ sy-vline
WA_ENT5002_STR-LOEKZ sy-vline
WA_ENT5002_STR-BANFN sy-vline
WA_ENT5002_STR-STATU sy-vline
WA_ENT5002_STR-FRGZU sy-vline
WA_ENT5002_STR-FRGST sy-vline
WA_ENT5002_STR-ERNAM sy-vline
WA_ENT5002_STR-ERDAT sy-vline
WA_ENT5002_STR-BNFPO sy-vline
WA_ENT5002_STR-LGORT sy-vline
WA_ENT5002_STR-FLIEF sy-vline
WA_ENT5002_STR-EKORG sy-vline
WA_ENT5002_STR-QUNUM sy-vline
WA_ENT5002_STR-QUPOS sy-vline
WA_ENT5002_STR-SERNR sy-vline
WA_ENT5002_STR-BUMNG sy-vline
WA_ENT5002_STR-LPEIN sy-vline
WA_ENT5002_STR-LFDAT sy-vline
WA_ENT5002_STR-WEBAZ sy-vline
WA_ENT5002_STR-PREIS sy-vline
WA_ENT5002_STR-PEINH sy-vline
WA_ENT5002_STR-KNTTP sy-vline
WA_ENT5002_STR-KZVBR sy-vline
WA_ENT5002_STR-WEPOS sy-vline
WA_ENT5002_STR-REPOS sy-vline
WA_ENT5002_STR-BSMNG sy-vline
WA_ENT5002_STR-KONNR sy-vline
WA_ENT5002_STR-KTPNR sy-vline
WA_ENT5002_STR-INFNR sy-vline
WA_ENT5002_STR-EBELN sy-vline
WA_ENT5002_STR-EBELP sy-vline
WA_ENT5002_STR-BWTAR sy-vline
WA_ENT5002_STR-VRTKZ sy-vline
WA_ENT5002_STR-TWRKZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.