ABAP Select data from SAP table ENT3070 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ENT3070 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ENT3070. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ENT3070 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ENT3070 TYPE STANDARD TABLE OF ENT3070,
      WA_ENT3070 TYPE ENT3070,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ENT3070> TYPE ENT3070.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ENT3070.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ENT3070
  INTO TABLE IT_ENT3070.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ENT3070
*  INTO TABLE @DATA(IT_ENT30702).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ENT3070 INDEX 1 INTO DATA(WA_ENT30702).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ENT3070 ASSIGNING <ENT3070>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ENT3070>-MANDT = 1.
<ENT3070>-KOKRS = 1.
<ENT3070>-BELNR = 1.
<ENT3070>-BUZEI = 1.
<ENT3070>-ABWNR = 1.
ENDLOOP.

LOOP AT IT_ENT3070 INTO WA_ENT3070.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ENT3070-BUREG, sy-vline,
WA_ENT3070-ABWST, sy-vline,
WA_ENT3070-ABWDA, sy-vline,
WA_ENT3070-WTGBTA, sy-vline,
WA_ENT3070-WOGBTA, sy-vline,
WA_ENT3070-WKGBTA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ENT3070 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ENT3070 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ENT3070 INTO WA_ENT3070. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT3070-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT3070-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WTGBTA CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_ENT3070-WTGBTA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT3070-WTGBTA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WOGBTA CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_ENT3070-WOGBTA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT3070-WOGBTA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WKGBTA CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_ENT3070-WKGBTA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT3070-WKGBTA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WKFBTA CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_ENT3070-WKFBTA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT3070-WKFBTA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field URZUO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ENT3070-URZUO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ENT3070-URZUO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ENT3070_STR,
MANDT TYPE STRING,
KOKRS TYPE STRING,
BELNR TYPE STRING,
BUZEI TYPE STRING,
ABWNR TYPE STRING,
BUREG TYPE STRING,
ABWST TYPE STRING,
ABWDA TYPE STRING,
WTGBTA TYPE STRING,
WOGBTA TYPE STRING,
WKGBTA TYPE STRING,
WKFBTA TYPE STRING,
OBJNR TYPE STRING,
URZUO TYPE STRING,
XSTOR TYPE STRING,END OF T_EKKO_STR. DATA: WA_ENT3070_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ENT3070_STR-MANDT sy-vline
WA_ENT3070_STR-KOKRS sy-vline
WA_ENT3070_STR-BELNR sy-vline
WA_ENT3070_STR-BUZEI sy-vline
WA_ENT3070_STR-ABWNR sy-vline
WA_ENT3070_STR-BUREG sy-vline
WA_ENT3070_STR-ABWST sy-vline
WA_ENT3070_STR-ABWDA sy-vline
WA_ENT3070_STR-WTGBTA sy-vline
WA_ENT3070_STR-WOGBTA sy-vline
WA_ENT3070_STR-WKGBTA sy-vline
WA_ENT3070_STR-WKFBTA sy-vline
WA_ENT3070_STR-OBJNR sy-vline
WA_ENT3070_STR-URZUO sy-vline
WA_ENT3070_STR-XSTOR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.