ABAP Select data from SAP table EMRDRESULTCRTRC_APPLDATA_IN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EMRDRESULTCRTRC_APPLDATA_IN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EMRDRESULTCRTRC_APPLDATA_IN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EMRDRESULTCRTRC_APPLDATA_IN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EMRDRESULTCRTRC_APPLDATA_IN TYPE STANDARD TABLE OF EMRDRESULTCRTRC_APPLDATA_IN,
      WA_EMRDRESULTCRTRC_APPLDATA_IN TYPE EMRDRESULTCRTRC_APPLDATA_IN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EMRDRESULTCRTRC_APPLDATA_IN> TYPE EMRDRESULTCRTRC_APPLDATA_IN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EMRDRESULTCRTRC_APPLDATA_IN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EMRDRESULTCRTRC_APPLDATA_IN
  INTO TABLE IT_EMRDRESULTCRTRC_APPLDATA_IN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EMRDRESULTCRTRC_APPLDATA_IN
*  INTO TABLE @DATA(IT_EMRDRESULTCRTRC_APPLDATA_IN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EMRDRESULTCRTRC_APPLDATA_IN INDEX 1 INTO DATA(WA_EMRDRESULTCRTRC_APPLDATA_IN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EMRDRESULTCRTRC_APPLDATA_IN ASSIGNING <EMRDRESULTCRTRC_APPLDATA_IN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EMRDRESULTCRTRC_APPLDATA_IN>-MATERIAL = 1.
<EMRDRESULTCRTRC_APPLDATA_IN>-SERIALNO = 1.
<EMRDRESULTCRTRC_APPLDATA_IN>-REGISTER = 1.
<EMRDRESULTCRTRC_APPLDATA_IN>-MRREASON = 1.
<EMRDRESULTCRTRC_APPLDATA_IN>-MRIDNUMBER = 1.
ENDLOOP.

LOOP AT IT_EMRDRESULTCRTRC_APPLDATA_IN INTO WA_EMRDRESULTCRTRC_APPLDATA_IN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EMRDRESULTCRTRC_APPLDATA_IN-READINGRESULT, sy-vline,
WA_EMRDRESULTCRTRC_APPLDATA_IN-METERREADINGNOTE, sy-vline,
WA_EMRDRESULTCRTRC_APPLDATA_IN-ACTUALCUSTOMERMRTYPE, sy-vline,
WA_EMRDRESULTCRTRC_APPLDATA_IN-METERREADER, sy-vline,
WA_EMRDRESULTCRTRC_APPLDATA_IN-MRDATEFORBILLING, sy-vline,
WA_EMRDRESULTCRTRC_APPLDATA_IN-MRTIMEFORBILLING, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EMRDRESULTCRTRC_APPLDATA_IN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EMRDRESULTCRTRC_APPLDATA_IN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EMRDRESULTCRTRC_APPLDATA_IN INTO WA_EMRDRESULTCRTRC_APPLDATA_IN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN5, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN5_OUTPUT' EXPORTING input = WA_EMRDRESULTCRTRC_APPLDATA_IN-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EMRDRESULTCRTRC_APPLDATA_IN-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field SERIALNO CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_EMRDRESULTCRTRC_APPLDATA_IN-SERIALNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EMRDRESULTCRTRC_APPLDATA_IN-SERIALNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MRIDNUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EMRDRESULTCRTRC_APPLDATA_IN-MRIDNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EMRDRESULTCRTRC_APPLDATA_IN-MRIDNUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit HH_MM, internal->external for field MRTIMEFORBILLING CALL FUNCTION 'CONVERSION_EXIT_HH_MM_OUTPUT' EXPORTING input = WA_EMRDRESULTCRTRC_APPLDATA_IN-MRTIMEFORBILLING IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EMRDRESULTCRTRC_APPLDATA_IN-MRTIMEFORBILLING.
WRITE:/ 'New Value:', ld_input.

*Conversion exit HH_MM, internal->external for field ACTUALMRTIME CALL FUNCTION 'CONVERSION_EXIT_HH_MM_OUTPUT' EXPORTING input = WA_EMRDRESULTCRTRC_APPLDATA_IN-ACTUALMRTIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EMRDRESULTCRTRC_APPLDATA_IN-ACTUALMRTIME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit HH_MM, internal->external for field MRTIMEOFMAXIMUM CALL FUNCTION 'CONVERSION_EXIT_HH_MM_OUTPUT' EXPORTING input = WA_EMRDRESULTCRTRC_APPLDATA_IN-MRTIMEOFMAXIMUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EMRDRESULTCRTRC_APPLDATA_IN-MRTIMEOFMAXIMUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SMORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EMRDRESULTCRTRC_APPLDATA_IN-SMORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EMRDRESULTCRTRC_APPLDATA_IN-SMORDER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL_LONG CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EMRDRESULTCRTRC_APPLDATA_IN-MATERIAL_LONG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EMRDRESULTCRTRC_APPLDATA_IN-MATERIAL_LONG.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EMRDRESULTCRTRC_APPLDATA_IN_STR,
MATERIAL TYPE STRING,
SERIALNO TYPE STRING,
REGISTER TYPE STRING,
MRREASON TYPE STRING,
MRIDNUMBER TYPE STRING,
READINGRESULT TYPE STRING,
METERREADINGNOTE TYPE STRING,
ACTUALCUSTOMERMRTYPE TYPE STRING,
METERREADER TYPE STRING,
MRDATEFORBILLING TYPE STRING,
MRTIMEFORBILLING TYPE STRING,
ACTUALMRDATE TYPE STRING,
ACTUALMRTIME TYPE STRING,
MRDATEOFMAXIMUM TYPE STRING,
MRTIMEOFMAXIMUM TYPE STRING,
SMORDER TYPE STRING,
ACTIVE TYPE STRING,
REFNUMBER TYPE STRING,
TARGETMRDATE TYPE STRING,
EXT_UI TYPE STRING,
MRDATEFORIDENTIF TYPE STRING,
MATERIAL_LONG TYPE STRING,END OF T_EKKO_STR. DATA: WA_EMRDRESULTCRTRC_APPLDATA_IN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EMRDRESULTCRTRC_APPLDATA_IN_STR-MATERIAL sy-vline
WA_EMRDRESULTCRTRC_APPLDATA_IN_STR-SERIALNO sy-vline
WA_EMRDRESULTCRTRC_APPLDATA_IN_STR-REGISTER sy-vline
WA_EMRDRESULTCRTRC_APPLDATA_IN_STR-MRREASON sy-vline
WA_EMRDRESULTCRTRC_APPLDATA_IN_STR-MRIDNUMBER sy-vline
WA_EMRDRESULTCRTRC_APPLDATA_IN_STR-READINGRESULT sy-vline
WA_EMRDRESULTCRTRC_APPLDATA_IN_STR-METERREADINGNOTE sy-vline
WA_EMRDRESULTCRTRC_APPLDATA_IN_STR-ACTUALCUSTOMERMRTYPE sy-vline
WA_EMRDRESULTCRTRC_APPLDATA_IN_STR-METERREADER sy-vline
WA_EMRDRESULTCRTRC_APPLDATA_IN_STR-MRDATEFORBILLING sy-vline
WA_EMRDRESULTCRTRC_APPLDATA_IN_STR-MRTIMEFORBILLING sy-vline
WA_EMRDRESULTCRTRC_APPLDATA_IN_STR-ACTUALMRDATE sy-vline
WA_EMRDRESULTCRTRC_APPLDATA_IN_STR-ACTUALMRTIME sy-vline
WA_EMRDRESULTCRTRC_APPLDATA_IN_STR-MRDATEOFMAXIMUM sy-vline
WA_EMRDRESULTCRTRC_APPLDATA_IN_STR-MRTIMEOFMAXIMUM sy-vline
WA_EMRDRESULTCRTRC_APPLDATA_IN_STR-SMORDER sy-vline
WA_EMRDRESULTCRTRC_APPLDATA_IN_STR-ACTIVE sy-vline
WA_EMRDRESULTCRTRC_APPLDATA_IN_STR-REFNUMBER sy-vline
WA_EMRDRESULTCRTRC_APPLDATA_IN_STR-TARGETMRDATE sy-vline
WA_EMRDRESULTCRTRC_APPLDATA_IN_STR-EXT_UI sy-vline
WA_EMRDRESULTCRTRC_APPLDATA_IN_STR-MRDATEFORIDENTIF sy-vline
WA_EMRDRESULTCRTRC_APPLDATA_IN_STR-MATERIAL_LONG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.