ABAP Select data from SAP table ELM_INFOSET_STRUCTURE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ELM_INFOSET_STRUCTURE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ELM_INFOSET_STRUCTURE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ELM_INFOSET_STRUCTURE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ELM_INFOSET_STRUCTURE TYPE STANDARD TABLE OF ELM_INFOSET_STRUCTURE,
      WA_ELM_INFOSET_STRUCTURE TYPE ELM_INFOSET_STRUCTURE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ELM_INFOSET_STRUCTURE> TYPE ELM_INFOSET_STRUCTURE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ELM_INFOSET_STRUCTURE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ELM_INFOSET_STRUCTURE
  INTO TABLE IT_ELM_INFOSET_STRUCTURE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ELM_INFOSET_STRUCTURE
*  INTO TABLE @DATA(IT_ELM_INFOSET_STRUCTURE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ELM_INFOSET_STRUCTURE INDEX 1 INTO DATA(WA_ELM_INFOSET_STRUCTURE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ELM_INFOSET_STRUCTURE ASSIGNING <ELM_INFOSET_STRUCTURE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ELM_INFOSET_STRUCTURE>-LIST_GUID = 1.
<ELM_INFOSET_STRUCTURE>-LIST_ID = 1.
<ELM_INFOSET_STRUCTURE>-LIST_ID_LOGSYS = 1.
<ELM_INFOSET_STRUCTURE>-ORIGIN = 1.
<ELM_INFOSET_STRUCTURE>-TYPE = 1.
ENDLOOP.

LOOP AT IT_ELM_INFOSET_STRUCTURE INTO WA_ELM_INFOSET_STRUCTURE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ELM_INFOSET_STRUCTURE-VALID_DATE_TO, sy-vline,
WA_ELM_INFOSET_STRUCTURE-MAX_USAGE_NO, sy-vline,
WA_ELM_INFOSET_STRUCTURE-MAX_USAGE_DATE, sy-vline,
WA_ELM_INFOSET_STRUCTURE-NO_GROSS, sy-vline,
WA_ELM_INFOSET_STRUCTURE-COSTS, sy-vline,
WA_ELM_INFOSET_STRUCTURE-COSTS_CURRENCY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ELM_INFOSET_STRUCTURE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ELM_INFOSET_STRUCTURE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ELM_INFOSET_STRUCTURE INTO WA_ELM_INFOSET_STRUCTURE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field LIST_ID_LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ELM_INFOSET_STRUCTURE-LIST_ID_LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ELM_INFOSET_STRUCTURE-LIST_ID_LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGUAGE CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_ELM_INFOSET_STRUCTURE-LANGUAGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ELM_INFOSET_STRUCTURE-LANGUAGE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ELM_INFOSET_STRUCTURE_STR,
LIST_GUID TYPE STRING,
LIST_ID TYPE STRING,
LIST_ID_LOGSYS TYPE STRING,
ORIGIN TYPE STRING,
TYPE TYPE STRING,
VALID_DATE_TO TYPE STRING,
MAX_USAGE_NO TYPE STRING,
MAX_USAGE_DATE TYPE STRING,
NO_GROSS TYPE STRING,
COSTS TYPE STRING,
COSTS_CURRENCY TYPE STRING,
HEADER_CUSTOMER_EXT TYPE STRING,
LANGUAGE TYPE STRING,
DESCRIPTION TYPE STRING,
TEXT_CUSTOMER_EXT TYPE STRING,
ITEM_GUID TYPE STRING,
CONTACTED TYPE STRING,
WON TYPE STRING,
POSTAL_ERROR TYPE STRING,
DUPLICATE TYPE STRING,
CITY TYPE STRING,
POSTL_COD1 TYPE STRING,
POSTL_COD2 TYPE STRING,
PO_BOX TYPE STRING,
PO_BOX_CIT TYPE STRING,
STREET TYPE STRING,
HOUSE_NO TYPE STRING,
COUNTRYISO TYPE STRING,
REGION TYPE STRING,
ID_NUMBER TYPE STRING,
NATION TYPE STRING,
ORG_TITLE_KEY TYPE STRING,
ORG_NAME1 TYPE STRING,
ORG_NAME2 TYPE STRING,
ORG_NAME3 TYPE STRING,
ORG_LEGALFORM TYPE STRING,
ORG_FOUND_DATE TYPE STRING,
ORG_TELEPHONE TYPE STRING,
ORG_TEL_EXT TYPE STRING,
ORG_FAX TYPE STRING,
ORG_FAX_EXT TYPE STRING,
ORG_URI TYPE STRING,
PERS_TITLE_KEY TYPE STRING,
PERS_FIRSTNAME TYPE STRING,
PERS_LASTNAME TYPE STRING,
PERS_INITIAL TYPE STRING,
PERS_TITLE_ACA1 TYPE STRING,
PERS_BIRTHDATE TYPE STRING,
PERS_SEX TYPE STRING,
PERS_MARITALSTAT TYPE STRING,
PERS_TELEPHON TYPE STRING,
PERS_TEL_EXT TYPE STRING,
PERS_FAX TYPE STRING,
PERS_FAX_EXT TYPE STRING,
PERS_E_MAIL TYPE STRING,
PERS_PAGER TYPE STRING,
CP_FUNCTIONNAME TYPE STRING,
CP_FUNCTIONKEY TYPE STRING,
ITEM_CUSTOMER_EXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_ELM_INFOSET_STRUCTURE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-LIST_GUID sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-LIST_ID sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-LIST_ID_LOGSYS sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-ORIGIN sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-TYPE sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-VALID_DATE_TO sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-MAX_USAGE_NO sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-MAX_USAGE_DATE sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-NO_GROSS sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-COSTS sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-COSTS_CURRENCY sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-HEADER_CUSTOMER_EXT sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-LANGUAGE sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-DESCRIPTION sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-TEXT_CUSTOMER_EXT sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-ITEM_GUID sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-CONTACTED sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-WON sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-POSTAL_ERROR sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-DUPLICATE sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-CITY sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-POSTL_COD1 sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-POSTL_COD2 sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-PO_BOX sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-PO_BOX_CIT sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-STREET sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-HOUSE_NO sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-COUNTRYISO sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-REGION sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-ID_NUMBER sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-NATION sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-ORG_TITLE_KEY sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-ORG_NAME1 sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-ORG_NAME2 sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-ORG_NAME3 sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-ORG_LEGALFORM sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-ORG_FOUND_DATE sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-ORG_TELEPHONE sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-ORG_TEL_EXT sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-ORG_FAX sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-ORG_FAX_EXT sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-ORG_URI sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-PERS_TITLE_KEY sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-PERS_FIRSTNAME sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-PERS_LASTNAME sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-PERS_INITIAL sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-PERS_TITLE_ACA1 sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-PERS_BIRTHDATE sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-PERS_SEX sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-PERS_MARITALSTAT sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-PERS_TELEPHON sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-PERS_TEL_EXT sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-PERS_FAX sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-PERS_FAX_EXT sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-PERS_E_MAIL sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-PERS_PAGER sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-CP_FUNCTIONNAME sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-CP_FUNCTIONKEY sy-vline
WA_ELM_INFOSET_STRUCTURE_STR-ITEM_CUSTOMER_EXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.