ABAP Select data from SAP table EKBZDATA_MA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EKBZDATA_MA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EKBZDATA_MA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EKBZDATA_MA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EKBZDATA_MA TYPE STANDARD TABLE OF EKBZDATA_MA,
      WA_EKBZDATA_MA TYPE EKBZDATA_MA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EKBZDATA_MA> TYPE EKBZDATA_MA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EKBZDATA_MA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EKBZDATA_MA
  INTO TABLE IT_EKBZDATA_MA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EKBZDATA_MA
*  INTO TABLE @DATA(IT_EKBZDATA_MA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EKBZDATA_MA INDEX 1 INTO DATA(WA_EKBZDATA_MA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EKBZDATA_MA ASSIGNING <EKBZDATA_MA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EKBZDATA_MA>-SHARE_F = 1.
<EKBZDATA_MA>-XUNPL = 1.
<EKBZDATA_MA>-SHKZG = 1.
<EKBZDATA_MA>-MENGE_F = 1.
<EKBZDATA_MA>-BPMNG_F = 1.
ENDLOOP.

LOOP AT IT_EKBZDATA_MA INTO WA_EKBZDATA_MA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EKBZDATA_MA-MENGE, sy-vline,
WA_EKBZDATA_MA-BPMNG, sy-vline,
WA_EKBZDATA_MA-DMBTR, sy-vline,
WA_EKBZDATA_MA-AREWR, sy-vline,
WA_EKBZDATA_MA-REEWR, sy-vline,
WA_EKBZDATA_MA-WRBTR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EKBZDATA_MA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EKBZDATA_MA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EKBZDATA_MA INTO WA_EKBZDATA_MA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EKBZDATA_MA_STR,
SHARE_F TYPE STRING,
XUNPL TYPE STRING,
SHKZG TYPE STRING,
MENGE_F TYPE STRING,
BPMNG_F TYPE STRING,
MENGE TYPE STRING,
BPMNG TYPE STRING,
DMBTR TYPE STRING,
AREWR TYPE STRING,
REEWR TYPE STRING,
WRBTR TYPE STRING,
AREWW TYPE STRING,
REFWR TYPE STRING,
AREWB TYPE STRING,
REWRB TYPE STRING,
KUDIF TYPE STRING,
CURTP2 TYPE STRING,
WAERS2 TYPE STRING,
DMBT2 TYPE STRING,
AREW2 TYPE STRING,
KUDIF2 TYPE STRING,
CURTP3 TYPE STRING,
WAERS3 TYPE STRING,
DMBT3 TYPE STRING,
AREW3 TYPE STRING,
KUDIF3 TYPE STRING,
_DATAAGING TYPE STRING,
SDM_VERSION TYPE STRING,END OF T_EKKO_STR. DATA: WA_EKBZDATA_MA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EKBZDATA_MA_STR-SHARE_F sy-vline
WA_EKBZDATA_MA_STR-XUNPL sy-vline
WA_EKBZDATA_MA_STR-SHKZG sy-vline
WA_EKBZDATA_MA_STR-MENGE_F sy-vline
WA_EKBZDATA_MA_STR-BPMNG_F sy-vline
WA_EKBZDATA_MA_STR-MENGE sy-vline
WA_EKBZDATA_MA_STR-BPMNG sy-vline
WA_EKBZDATA_MA_STR-DMBTR sy-vline
WA_EKBZDATA_MA_STR-AREWR sy-vline
WA_EKBZDATA_MA_STR-REEWR sy-vline
WA_EKBZDATA_MA_STR-WRBTR sy-vline
WA_EKBZDATA_MA_STR-AREWW sy-vline
WA_EKBZDATA_MA_STR-REFWR sy-vline
WA_EKBZDATA_MA_STR-AREWB sy-vline
WA_EKBZDATA_MA_STR-REWRB sy-vline
WA_EKBZDATA_MA_STR-KUDIF sy-vline
WA_EKBZDATA_MA_STR-CURTP2 sy-vline
WA_EKBZDATA_MA_STR-WAERS2 sy-vline
WA_EKBZDATA_MA_STR-DMBT2 sy-vline
WA_EKBZDATA_MA_STR-AREW2 sy-vline
WA_EKBZDATA_MA_STR-KUDIF2 sy-vline
WA_EKBZDATA_MA_STR-CURTP3 sy-vline
WA_EKBZDATA_MA_STR-WAERS3 sy-vline
WA_EKBZDATA_MA_STR-DMBT3 sy-vline
WA_EKBZDATA_MA_STR-AREW3 sy-vline
WA_EKBZDATA_MA_STR-KUDIF3 sy-vline
WA_EKBZDATA_MA_STR-_DATAAGING sy-vline
WA_EKBZDATA_MA_STR-SDM_VERSION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.