ABAP Select data from SAP table EISU_IL_MD_DEVICE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EISU_IL_MD_DEVICE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EISU_IL_MD_DEVICE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EISU_IL_MD_DEVICE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EISU_IL_MD_DEVICE TYPE STANDARD TABLE OF EISU_IL_MD_DEVICE,
      WA_EISU_IL_MD_DEVICE TYPE EISU_IL_MD_DEVICE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EISU_IL_MD_DEVICE> TYPE EISU_IL_MD_DEVICE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EISU_IL_MD_DEVICE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EISU_IL_MD_DEVICE
  INTO TABLE IT_EISU_IL_MD_DEVICE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EISU_IL_MD_DEVICE
*  INTO TABLE @DATA(IT_EISU_IL_MD_DEVICE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EISU_IL_MD_DEVICE INDEX 1 INTO DATA(WA_EISU_IL_MD_DEVICE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EISU_IL_MD_DEVICE ASSIGNING <EISU_IL_MD_DEVICE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EISU_IL_MD_DEVICE>-MANDT = 1.
<EISU_IL_MD_DEVICE>-EQUNR = 1.
<EISU_IL_MD_DEVICE>-DEVLOC = 1.
<EISU_IL_MD_DEVICE>-BIS = 1.
<EISU_IL_MD_DEVICE>-AB = 1.
ENDLOOP.

LOOP AT IT_EISU_IL_MD_DEVICE INTO WA_EISU_IL_MD_DEVICE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EISU_IL_MD_DEVICE-LOGIKNR, sy-vline,
WA_EISU_IL_MD_DEVICE-GERAET, sy-vline,
WA_EISU_IL_MD_DEVICE-MATNR, sy-vline,
WA_EISU_IL_MD_DEVICE-WERK, sy-vline,
WA_EISU_IL_MD_DEVICE-LAGER, sy-vline,
WA_EISU_IL_MD_DEVICE-ZWGRUPPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EISU_IL_MD_DEVICE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EISU_IL_MD_DEVICE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EISU_IL_MD_DEVICE INTO WA_EISU_IL_MD_DEVICE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EISU_IL_MD_DEVICE-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EISU_IL_MD_DEVICE-EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field DEVLOC CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_EISU_IL_MD_DEVICE-DEVLOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EISU_IL_MD_DEVICE-DEVLOC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field GERAET CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_EISU_IL_MD_DEVICE-GERAET IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EISU_IL_MD_DEVICE-GERAET.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EISU_IL_MD_DEVICE-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EISU_IL_MD_DEVICE-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ZWGRUPPE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EISU_IL_MD_DEVICE-ZWGRUPPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EISU_IL_MD_DEVICE-ZWGRUPPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WGRUPPE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EISU_IL_MD_DEVICE-WGRUPPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EISU_IL_MD_DEVICE-WGRUPPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EAGRUPPE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EISU_IL_MD_DEVICE-EAGRUPPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EISU_IL_MD_DEVICE-EAGRUPPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOMGRP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EISU_IL_MD_DEVICE-KOMGRP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EISU_IL_MD_DEVICE-KOMGRP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EISU_IL_MD_DEVICE-LOS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EISU_IL_MD_DEVICE-LOS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field BAUJJ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_EISU_IL_MD_DEVICE-BAUJJ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EISU_IL_MD_DEVICE-BAUJJ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DEVGRP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EISU_IL_MD_DEVICE-DEVGRP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EISU_IL_MD_DEVICE-DEVGRP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit RAT11, internal->external for field RATING CALL FUNCTION 'CONVERSION_EXIT_RAT11_OUTPUT' EXPORTING input = WA_EISU_IL_MD_DEVICE-RATING IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EISU_IL_MD_DEVICE-RATING.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PVOLT, internal->external for field P_VOLTAGE CALL FUNCTION 'CONVERSION_EXIT_PVOLT_OUTPUT' EXPORTING input = WA_EISU_IL_MD_DEVICE-P_VOLTAGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EISU_IL_MD_DEVICE-P_VOLTAGE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SVOLT, internal->external for field S_VOLTAGE CALL FUNCTION 'CONVERSION_EXIT_SVOLT_OUTPUT' EXPORTING input = WA_EISU_IL_MD_DEVICE-S_VOLTAGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EISU_IL_MD_DEVICE-S_VOLTAGE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MSG_LENGTH CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EISU_IL_MD_DEVICE-MSG_LENGTH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EISU_IL_MD_DEVICE-MSG_LENGTH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EISU_IL_MD_DEVICE_STR,
MANDT TYPE STRING,
EQUNR TYPE STRING,
DEVLOC TYPE STRING,
BIS TYPE STRING,
AB TYPE STRING,
LOGIKNR TYPE STRING,
GERAET TYPE STRING,
MATNR TYPE STRING,
WERK TYPE STRING,
LAGER TYPE STRING,
ZWGRUPPE TYPE STRING,
EINBDAT TYPE STRING,
AUSBDAT TYPE STRING,
GERWECHS TYPE STRING,
WGRUPPE TYPE STRING,
PRIMWNR1 TYPE STRING,
SEKWNR1 TYPE STRING,
PRIMWNR2 TYPE STRING,
SEKWNR2 TYPE STRING,
EAGRUPPE TYPE STRING,
KOMGRP TYPE STRING,
LOS TYPE STRING,
MESSDRCK TYPE STRING,
UEBERVER TYPE STRING,
BESITZ TYPE STRING,
BGLJAHR TYPE STRING,
WECHSEL TYPE STRING,
BGLSTAT TYPE STRING,
KZSTICH TYPE STRING,
SCHWGRAD TYPE STRING,
PLOMBDAT TYPE STRING,
HERST TYPE STRING,
BGLART TYPE STRING,
BGLNUM TYPE STRING,
UMBAUDAT TYPE STRING,
UMBAUGR TYPE STRING,
EICHFAEL TYPE STRING,
PARAMETR TYPE STRING,
PLOMBE TYPE STRING,
ERDAT TYPE STRING,
ERNAM TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
ZSPANNP TYPE STRING,
ZSPANNS TYPE STRING,
ZSTROMP TYPE STRING,
ZSTROMS TYPE STRING,
BAUJJ TYPE STRING,
DEVGRP TYPE STRING,
SPARTE TYPE STRING,
TYPBZ TYPE STRING,
APPROVALNR TYPE STRING,
VLZEIT_DEV TYPE STRING,
KOMBINAT TYPE STRING,
BGLNETZ TYPE STRING,
ORDER_CODE TYPE STRING,
NOTIF_CODE TYPE STRING,
S_EQBS TYPE STRING,
PPM_METER TYPE STRING,
OBJNR TYPE STRING,
LOSSDTGROUP TYPE STRING,
RATING TYPE STRING,
P_VOLTAGE TYPE STRING,
S_VOLTAGE TYPE STRING,
AMS TYPE STRING,
AMCG_CAP_GRP TYPE STRING,
SERVICE_PROV TYPE STRING,
EGERR_INFO TYPE STRING,
BEGRU TYPE STRING,
SHORTTEXT TYPE STRING,
BAUFORM TYPE STRING,
AMI_DEVICE TYPE STRING,
AMI_ACTIVE TYPE STRING,
UII TYPE STRING,
LOCKED TYPE STRING,
LOCK_INFO TYPE STRING,
SMART_METER_TYPE TYPE STRING,
MSG_LENGTH TYPE STRING,END OF T_EKKO_STR. DATA: WA_EISU_IL_MD_DEVICE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EISU_IL_MD_DEVICE_STR-MANDT sy-vline
WA_EISU_IL_MD_DEVICE_STR-EQUNR sy-vline
WA_EISU_IL_MD_DEVICE_STR-DEVLOC sy-vline
WA_EISU_IL_MD_DEVICE_STR-BIS sy-vline
WA_EISU_IL_MD_DEVICE_STR-AB sy-vline
WA_EISU_IL_MD_DEVICE_STR-LOGIKNR sy-vline
WA_EISU_IL_MD_DEVICE_STR-GERAET sy-vline
WA_EISU_IL_MD_DEVICE_STR-MATNR sy-vline
WA_EISU_IL_MD_DEVICE_STR-WERK sy-vline
WA_EISU_IL_MD_DEVICE_STR-LAGER sy-vline
WA_EISU_IL_MD_DEVICE_STR-ZWGRUPPE sy-vline
WA_EISU_IL_MD_DEVICE_STR-EINBDAT sy-vline
WA_EISU_IL_MD_DEVICE_STR-AUSBDAT sy-vline
WA_EISU_IL_MD_DEVICE_STR-GERWECHS sy-vline
WA_EISU_IL_MD_DEVICE_STR-WGRUPPE sy-vline
WA_EISU_IL_MD_DEVICE_STR-PRIMWNR1 sy-vline
WA_EISU_IL_MD_DEVICE_STR-SEKWNR1 sy-vline
WA_EISU_IL_MD_DEVICE_STR-PRIMWNR2 sy-vline
WA_EISU_IL_MD_DEVICE_STR-SEKWNR2 sy-vline
WA_EISU_IL_MD_DEVICE_STR-EAGRUPPE sy-vline
WA_EISU_IL_MD_DEVICE_STR-KOMGRP sy-vline
WA_EISU_IL_MD_DEVICE_STR-LOS sy-vline
WA_EISU_IL_MD_DEVICE_STR-MESSDRCK sy-vline
WA_EISU_IL_MD_DEVICE_STR-UEBERVER sy-vline
WA_EISU_IL_MD_DEVICE_STR-BESITZ sy-vline
WA_EISU_IL_MD_DEVICE_STR-BGLJAHR sy-vline
WA_EISU_IL_MD_DEVICE_STR-WECHSEL sy-vline
WA_EISU_IL_MD_DEVICE_STR-BGLSTAT sy-vline
WA_EISU_IL_MD_DEVICE_STR-KZSTICH sy-vline
WA_EISU_IL_MD_DEVICE_STR-SCHWGRAD sy-vline
WA_EISU_IL_MD_DEVICE_STR-PLOMBDAT sy-vline
WA_EISU_IL_MD_DEVICE_STR-HERST sy-vline
WA_EISU_IL_MD_DEVICE_STR-BGLART sy-vline
WA_EISU_IL_MD_DEVICE_STR-BGLNUM sy-vline
WA_EISU_IL_MD_DEVICE_STR-UMBAUDAT sy-vline
WA_EISU_IL_MD_DEVICE_STR-UMBAUGR sy-vline
WA_EISU_IL_MD_DEVICE_STR-EICHFAEL sy-vline
WA_EISU_IL_MD_DEVICE_STR-PARAMETR sy-vline
WA_EISU_IL_MD_DEVICE_STR-PLOMBE sy-vline
WA_EISU_IL_MD_DEVICE_STR-ERDAT sy-vline
WA_EISU_IL_MD_DEVICE_STR-ERNAM sy-vline
WA_EISU_IL_MD_DEVICE_STR-AEDAT sy-vline
WA_EISU_IL_MD_DEVICE_STR-AENAM sy-vline
WA_EISU_IL_MD_DEVICE_STR-ZSPANNP sy-vline
WA_EISU_IL_MD_DEVICE_STR-ZSPANNS sy-vline
WA_EISU_IL_MD_DEVICE_STR-ZSTROMP sy-vline
WA_EISU_IL_MD_DEVICE_STR-ZSTROMS sy-vline
WA_EISU_IL_MD_DEVICE_STR-BAUJJ sy-vline
WA_EISU_IL_MD_DEVICE_STR-DEVGRP sy-vline
WA_EISU_IL_MD_DEVICE_STR-SPARTE sy-vline
WA_EISU_IL_MD_DEVICE_STR-TYPBZ sy-vline
WA_EISU_IL_MD_DEVICE_STR-APPROVALNR sy-vline
WA_EISU_IL_MD_DEVICE_STR-VLZEIT_DEV sy-vline
WA_EISU_IL_MD_DEVICE_STR-KOMBINAT sy-vline
WA_EISU_IL_MD_DEVICE_STR-BGLNETZ sy-vline
WA_EISU_IL_MD_DEVICE_STR-ORDER_CODE sy-vline
WA_EISU_IL_MD_DEVICE_STR-NOTIF_CODE sy-vline
WA_EISU_IL_MD_DEVICE_STR-S_EQBS sy-vline
WA_EISU_IL_MD_DEVICE_STR-PPM_METER sy-vline
WA_EISU_IL_MD_DEVICE_STR-OBJNR sy-vline
WA_EISU_IL_MD_DEVICE_STR-LOSSDTGROUP sy-vline
WA_EISU_IL_MD_DEVICE_STR-RATING sy-vline
WA_EISU_IL_MD_DEVICE_STR-P_VOLTAGE sy-vline
WA_EISU_IL_MD_DEVICE_STR-S_VOLTAGE sy-vline
WA_EISU_IL_MD_DEVICE_STR-AMS sy-vline
WA_EISU_IL_MD_DEVICE_STR-AMCG_CAP_GRP sy-vline
WA_EISU_IL_MD_DEVICE_STR-SERVICE_PROV sy-vline
WA_EISU_IL_MD_DEVICE_STR-EGERR_INFO sy-vline
WA_EISU_IL_MD_DEVICE_STR-BEGRU sy-vline
WA_EISU_IL_MD_DEVICE_STR-SHORTTEXT sy-vline
WA_EISU_IL_MD_DEVICE_STR-BAUFORM sy-vline
WA_EISU_IL_MD_DEVICE_STR-AMI_DEVICE sy-vline
WA_EISU_IL_MD_DEVICE_STR-AMI_ACTIVE sy-vline
WA_EISU_IL_MD_DEVICE_STR-UII sy-vline
WA_EISU_IL_MD_DEVICE_STR-LOCKED sy-vline
WA_EISU_IL_MD_DEVICE_STR-LOCK_INFO sy-vline
WA_EISU_IL_MD_DEVICE_STR-SMART_METER_TYPE sy-vline
WA_EISU_IL_MD_DEVICE_STR-MSG_LENGTH sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.