ABAP Select data from SAP table EHSWAV_APPBPCON into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHSWAV_APPBPCON table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHSWAV_APPBPCON. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHSWAV_APPBPCON table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHSWAV_APPBPCON TYPE STANDARD TABLE OF EHSWAV_APPBPCON,
      WA_EHSWAV_APPBPCON TYPE EHSWAV_APPBPCON,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHSWAV_APPBPCON> TYPE EHSWAV_APPBPCON.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHSWAV_APPBPCON.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHSWAV_APPBPCON
  INTO TABLE IT_EHSWAV_APPBPCON.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHSWAV_APPBPCON
*  INTO TABLE @DATA(IT_EHSWAV_APPBPCON2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHSWAV_APPBPCON INDEX 1 INTO DATA(WA_EHSWAV_APPBPCON2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHSWAV_APPBPCON ASSIGNING <EHSWAV_APPBPCON>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHSWAV_APPBPCON>-MANDT = 1.
<EHSWAV_APPBPCON>-RECN = 1.
<EHSWAV_APPBPCON>-ACTN = 1.
<EHSWAV_APPBPCON>-VALFR = 1.
<EHSWAV_APPBPCON>-VALTO = 1.
ENDLOOP.

LOOP AT IT_EHSWAV_APPBPCON INTO WA_EHSWAV_APPBPCON.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHSWAV_APPBPCON-AENNR, sy-vline,
WA_EHSWAV_APPBPCON-DELFLG, sy-vline,
WA_EHSWAV_APPBPCON-PARKFLG, sy-vline,
WA_EHSWAV_APPBPCON-CRDAT, sy-vline,
WA_EHSWAV_APPBPCON-CRNAM, sy-vline,
WA_EHSWAV_APPBPCON-UPDDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHSWAV_APPBPCON you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHSWAV_APPBPCON TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHSWAV_APPBPCON INTO WA_EHSWAV_APPBPCON. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHSWAV_APPBPCON-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSWAV_APPBPCON-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OWNID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHSWAV_APPBPCON-OWNID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSWAV_APPBPCON-OWNID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHSWAV_APPBPCON-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSWAV_APPBPCON-EBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHSWAV_APPBPCON-VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSWAV_APPBPCON-VBELN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHSWAV_APPBPCON_STR,
MANDT TYPE STRING,
RECN TYPE STRING,
ACTN TYPE STRING,
VALFR TYPE STRING,
VALTO TYPE STRING,
AENNR TYPE STRING,
DELFLG TYPE STRING,
PARKFLG TYPE STRING,
CRDAT TYPE STRING,
CRNAM TYPE STRING,
UPDDAT TYPE STRING,
UPDNAM TYPE STRING,
SRSID TYPE STRING,
OWNID TYPE STRING,
RECNROOT TYPE STRING,
RECNBPWA TYPE STRING,
CONVALFR TYPE STRING,
CONVALTO TYPE STRING,
EBELN TYPE STRING,
EBELP TYPE STRING,
VBELN TYPE STRING,
VBAP TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHSWAV_APPBPCON_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHSWAV_APPBPCON_STR-MANDT sy-vline
WA_EHSWAV_APPBPCON_STR-RECN sy-vline
WA_EHSWAV_APPBPCON_STR-ACTN sy-vline
WA_EHSWAV_APPBPCON_STR-VALFR sy-vline
WA_EHSWAV_APPBPCON_STR-VALTO sy-vline
WA_EHSWAV_APPBPCON_STR-AENNR sy-vline
WA_EHSWAV_APPBPCON_STR-DELFLG sy-vline
WA_EHSWAV_APPBPCON_STR-PARKFLG sy-vline
WA_EHSWAV_APPBPCON_STR-CRDAT sy-vline
WA_EHSWAV_APPBPCON_STR-CRNAM sy-vline
WA_EHSWAV_APPBPCON_STR-UPDDAT sy-vline
WA_EHSWAV_APPBPCON_STR-UPDNAM sy-vline
WA_EHSWAV_APPBPCON_STR-SRSID sy-vline
WA_EHSWAV_APPBPCON_STR-OWNID sy-vline
WA_EHSWAV_APPBPCON_STR-RECNROOT sy-vline
WA_EHSWAV_APPBPCON_STR-RECNBPWA sy-vline
WA_EHSWAV_APPBPCON_STR-CONVALFR sy-vline
WA_EHSWAV_APPBPCON_STR-CONVALTO sy-vline
WA_EHSWAV_APPBPCON_STR-EBELN sy-vline
WA_EHSWAV_APPBPCON_STR-EBELP sy-vline
WA_EHSWAV_APPBPCON_STR-VBELN sy-vline
WA_EHSWAV_APPBPCON_STR-VBAP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.