ABAP Select data from SAP table EHSWAT_APPWAKEY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHSWAT_APPWAKEY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHSWAT_APPWAKEY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHSWAT_APPWAKEY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHSWAT_APPWAKEY TYPE STANDARD TABLE OF EHSWAT_APPWAKEY,
      WA_EHSWAT_APPWAKEY TYPE EHSWAT_APPWAKEY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHSWAT_APPWAKEY> TYPE EHSWAT_APPWAKEY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHSWAT_APPWAKEY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHSWAT_APPWAKEY
  INTO TABLE IT_EHSWAT_APPWAKEY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHSWAT_APPWAKEY
*  INTO TABLE @DATA(IT_EHSWAT_APPWAKEY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHSWAT_APPWAKEY INDEX 1 INTO DATA(WA_EHSWAT_APPWAKEY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHSWAT_APPWAKEY ASSIGNING <EHSWAT_APPWAKEY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHSWAT_APPWAKEY>-MANDT = 1.
<EHSWAT_APPWAKEY>-RECN = 1.
<EHSWAT_APPWAKEY>-ACTN = 1.
<EHSWAT_APPWAKEY>-VALFR = 1.
<EHSWAT_APPWAKEY>-VALTO = 1.
ENDLOOP.

LOOP AT IT_EHSWAT_APPWAKEY INTO WA_EHSWAT_APPWAKEY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHSWAT_APPWAKEY-AENNR, sy-vline,
WA_EHSWAT_APPWAKEY-DELFLG, sy-vline,
WA_EHSWAT_APPWAKEY-PARKFLG, sy-vline,
WA_EHSWAT_APPWAKEY-CRDAT, sy-vline,
WA_EHSWAT_APPWAKEY-CRNAM, sy-vline,
WA_EHSWAT_APPWAKEY-UPDDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHSWAT_APPWAKEY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHSWAT_APPWAKEY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHSWAT_APPWAKEY INTO WA_EHSWAT_APPWAKEY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHSWAT_APPWAKEY-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSWAT_APPWAKEY-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OWNID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHSWAT_APPWAKEY-OWNID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSWAT_APPWAKEY-OWNID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNWAKEY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHSWAT_APPWAKEY-RECNWAKEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSWAT_APPWAKEY-RECNWAKEY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field APCKU CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EHSWAT_APPWAKEY-APCKU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSWAT_APPWAKEY-APCKU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field APDISU CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EHSWAT_APPWAKEY-APDISU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSWAT_APPWAKEY-APDISU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field APPQUANU CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EHSWAT_APPWAKEY-APPQUANU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSWAT_APPWAKEY-APPQUANU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNSUBST CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHSWAT_APPWAKEY-RECNSUBST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSWAT_APPWAKEY-RECNSUBST.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHSWAT_APPWAKEY_STR,
MANDT TYPE STRING,
RECN TYPE STRING,
ACTN TYPE STRING,
VALFR TYPE STRING,
VALTO TYPE STRING,
AENNR TYPE STRING,
DELFLG TYPE STRING,
PARKFLG TYPE STRING,
CRDAT TYPE STRING,
CRNAM TYPE STRING,
UPDDAT TYPE STRING,
UPDNAM TYPE STRING,
SRSID TYPE STRING,
OWNID TYPE STRING,
RECNROOT TYPE STRING,
RECNWAKEY TYPE STRING,
APWAKEY TYPE STRING,
APCKQUAN TYPE STRING,
APCKU TYPE STRING,
APDISQUAN TYPE STRING,
APDISU TYPE STRING,
APPQUAN TYPE STRING,
APPQUANU TYPE STRING,
APDISCAT TYPE STRING,
APDISMETH TYPE STRING,
APDISPROC TYPE STRING,
APFRE TYPE STRING,
RECNSUBST TYPE STRING,
APPACCAT TYPE STRING,
APPDISPREAS TYPE STRING,
APWAKEYORD TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHSWAT_APPWAKEY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHSWAT_APPWAKEY_STR-MANDT sy-vline
WA_EHSWAT_APPWAKEY_STR-RECN sy-vline
WA_EHSWAT_APPWAKEY_STR-ACTN sy-vline
WA_EHSWAT_APPWAKEY_STR-VALFR sy-vline
WA_EHSWAT_APPWAKEY_STR-VALTO sy-vline
WA_EHSWAT_APPWAKEY_STR-AENNR sy-vline
WA_EHSWAT_APPWAKEY_STR-DELFLG sy-vline
WA_EHSWAT_APPWAKEY_STR-PARKFLG sy-vline
WA_EHSWAT_APPWAKEY_STR-CRDAT sy-vline
WA_EHSWAT_APPWAKEY_STR-CRNAM sy-vline
WA_EHSWAT_APPWAKEY_STR-UPDDAT sy-vline
WA_EHSWAT_APPWAKEY_STR-UPDNAM sy-vline
WA_EHSWAT_APPWAKEY_STR-SRSID sy-vline
WA_EHSWAT_APPWAKEY_STR-OWNID sy-vline
WA_EHSWAT_APPWAKEY_STR-RECNROOT sy-vline
WA_EHSWAT_APPWAKEY_STR-RECNWAKEY sy-vline
WA_EHSWAT_APPWAKEY_STR-APWAKEY sy-vline
WA_EHSWAT_APPWAKEY_STR-APCKQUAN sy-vline
WA_EHSWAT_APPWAKEY_STR-APCKU sy-vline
WA_EHSWAT_APPWAKEY_STR-APDISQUAN sy-vline
WA_EHSWAT_APPWAKEY_STR-APDISU sy-vline
WA_EHSWAT_APPWAKEY_STR-APPQUAN sy-vline
WA_EHSWAT_APPWAKEY_STR-APPQUANU sy-vline
WA_EHSWAT_APPWAKEY_STR-APDISCAT sy-vline
WA_EHSWAT_APPWAKEY_STR-APDISMETH sy-vline
WA_EHSWAT_APPWAKEY_STR-APDISPROC sy-vline
WA_EHSWAT_APPWAKEY_STR-APFRE sy-vline
WA_EHSWAT_APPWAKEY_STR-RECNSUBST sy-vline
WA_EHSWAT_APPWAKEY_STR-APPACCAT sy-vline
WA_EHSWAT_APPWAKEY_STR-APPDISPREAS sy-vline
WA_EHSWAT_APPWAKEY_STR-APWAKEYORD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.