ABAP Select data from SAP table EHSWAS_MN_PRI_WASTE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHSWAS_MN_PRI_WASTE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHSWAS_MN_PRI_WASTE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHSWAS_MN_PRI_WASTE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHSWAS_MN_PRI_WASTE TYPE STANDARD TABLE OF EHSWAS_MN_PRI_WASTE,
      WA_EHSWAS_MN_PRI_WASTE TYPE EHSWAS_MN_PRI_WASTE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHSWAS_MN_PRI_WASTE> TYPE EHSWAS_MN_PRI_WASTE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHSWAS_MN_PRI_WASTE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHSWAS_MN_PRI_WASTE
  INTO TABLE IT_EHSWAS_MN_PRI_WASTE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHSWAS_MN_PRI_WASTE
*  INTO TABLE @DATA(IT_EHSWAS_MN_PRI_WASTE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHSWAS_MN_PRI_WASTE INDEX 1 INTO DATA(WA_EHSWAS_MN_PRI_WASTE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHSWAS_MN_PRI_WASTE ASSIGNING <EHSWAS_MN_PRI_WASTE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHSWAS_MN_PRI_WASTE>-MNMATNR = 1.
<EHSWAS_MN_PRI_WASTE>-MNMATDES = 1.
<EHSWAS_MN_PRI_WASTE>-MNAMIN = 1.
<EHSWAS_MN_PRI_WASTE>-MNAMQIN = 1.
<EHSWAS_MN_PRI_WASTE>-MNAMEX = 1.
ENDLOOP.

LOOP AT IT_EHSWAS_MN_PRI_WASTE INTO WA_EHSWAS_MN_PRI_WASTE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHSWAS_MN_PRI_WASTE-MNAMQEX, sy-vline,
WA_EHSWAS_MN_PRI_WASTE-MNWACODE, sy-vline,
WA_EHSWAS_MN_PRI_WASTE-MNWACODEDES, sy-vline,
WA_EHSWAS_MN_PRI_WASTE-MNPACNUM, sy-vline,
WA_EHSWAS_MN_PRI_WASTE-MNPACCAT, sy-vline,
WA_EHSWAS_MN_PRI_WASTE-MNDGPOSFLG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHSWAS_MN_PRI_WASTE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHSWAS_MN_PRI_WASTE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHSWAS_MN_PRI_WASTE INTO WA_EHSWAS_MN_PRI_WASTE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MNMATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EHSWAS_MN_PRI_WASTE-MNMATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSWAS_MN_PRI_WASTE-MNMATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MNAMQIN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EHSWAS_MN_PRI_WASTE-MNAMQIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSWAS_MN_PRI_WASTE-MNAMQIN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MNAMQEX CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EHSWAS_MN_PRI_WASTE-MNAMQEX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSWAS_MN_PRI_WASTE-MNAMQEX.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHSWAS_MN_PRI_WASTE_STR,
MNMATNR TYPE STRING,
MNMATDES TYPE STRING,
MNAMIN TYPE STRING,
MNAMQIN TYPE STRING,
MNAMEX TYPE STRING,
MNAMQEX TYPE STRING,
MNWACODE TYPE STRING,
MNWACODEDES TYPE STRING,
MNPACNUM TYPE STRING,
MNPACCAT TYPE STRING,
MNDGPOSFLG TYPE STRING,
MNDGDATA TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHSWAS_MN_PRI_WASTE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHSWAS_MN_PRI_WASTE_STR-MNMATNR sy-vline
WA_EHSWAS_MN_PRI_WASTE_STR-MNMATDES sy-vline
WA_EHSWAS_MN_PRI_WASTE_STR-MNAMIN sy-vline
WA_EHSWAS_MN_PRI_WASTE_STR-MNAMQIN sy-vline
WA_EHSWAS_MN_PRI_WASTE_STR-MNAMEX sy-vline
WA_EHSWAS_MN_PRI_WASTE_STR-MNAMQEX sy-vline
WA_EHSWAS_MN_PRI_WASTE_STR-MNWACODE sy-vline
WA_EHSWAS_MN_PRI_WASTE_STR-MNWACODEDES sy-vline
WA_EHSWAS_MN_PRI_WASTE_STR-MNPACNUM sy-vline
WA_EHSWAS_MN_PRI_WASTE_STR-MNPACCAT sy-vline
WA_EHSWAS_MN_PRI_WASTE_STR-MNDGPOSFLG sy-vline
WA_EHSWAS_MN_PRI_WASTE_STR-MNDGDATA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.