ABAP Select data from SAP table EHSWAS_ENTAMEA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHSWAS_ENTAMEA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHSWAS_ENTAMEA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHSWAS_ENTAMEA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHSWAS_ENTAMEA TYPE STANDARD TABLE OF EHSWAS_ENTAMEA,
      WA_EHSWAS_ENTAMEA TYPE EHSWAS_ENTAMEA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHSWAS_ENTAMEA> TYPE EHSWAS_ENTAMEA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHSWAS_ENTAMEA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHSWAS_ENTAMEA
  INTO TABLE IT_EHSWAS_ENTAMEA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHSWAS_ENTAMEA
*  INTO TABLE @DATA(IT_EHSWAS_ENTAMEA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHSWAS_ENTAMEA INDEX 1 INTO DATA(WA_EHSWAS_ENTAMEA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHSWAS_ENTAMEA ASSIGNING <EHSWAS_ENTAMEA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHSWAS_ENTAMEA>-WERKS = 1.
<EHSWAS_ENTAMEA>-SEARCH_STRING = 1.
<EHSWAS_ENTAMEA>-EADAT = 1.
<EHSWAS_ENTAMEA>-SKIP_TO = 1.
<EHSWAS_ENTAMEA>-STTXT = 1.
ENDLOOP.

LOOP AT IT_EHSWAS_ENTAMEA INTO WA_EHSWAS_ENTAMEA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHSWAS_ENTAMEA-ASTEX, sy-vline,
WA_EHSWAS_ENTAMEA-ASTXT, sy-vline,
WA_EHSWAS_ENTAMEA-STAT_AB, sy-vline,
WA_EHSWAS_ENTAMEA-STAT_SELID, sy-vline,
WA_EHSWAS_ENTAMEA-STAT_BL, sy-vline,
WA_EHSWAS_ENTAMEA-STATIN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHSWAS_ENTAMEA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHSWAS_ENTAMEA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHSWAS_ENTAMEA INTO WA_EHSWAS_ENTAMEA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SKIP_TO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHSWAS_ENTAMEA-SKIP_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSWAS_ENTAMEA-SKIP_TO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHSWAS_ENTAMEA_STR,
WERKS TYPE STRING,
SEARCH_STRING TYPE STRING,
EADAT TYPE STRING,
SKIP_TO TYPE STRING,
STTXT TYPE STRING,
ASTEX TYPE STRING,
ASTXT TYPE STRING,
STAT_AB TYPE STRING,
STAT_SELID TYPE STRING,
STAT_BL TYPE STRING,
STATIN TYPE STRING,
STATEX TYPE STRING,
ANZDOC_TOTL TYPE STRING,
LTXT_EAN TYPE STRING,
PLANT_NAME TYPE STRING,
TTIME TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHSWAS_ENTAMEA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHSWAS_ENTAMEA_STR-WERKS sy-vline
WA_EHSWAS_ENTAMEA_STR-SEARCH_STRING sy-vline
WA_EHSWAS_ENTAMEA_STR-EADAT sy-vline
WA_EHSWAS_ENTAMEA_STR-SKIP_TO sy-vline
WA_EHSWAS_ENTAMEA_STR-STTXT sy-vline
WA_EHSWAS_ENTAMEA_STR-ASTEX sy-vline
WA_EHSWAS_ENTAMEA_STR-ASTXT sy-vline
WA_EHSWAS_ENTAMEA_STR-STAT_AB sy-vline
WA_EHSWAS_ENTAMEA_STR-STAT_SELID sy-vline
WA_EHSWAS_ENTAMEA_STR-STAT_BL sy-vline
WA_EHSWAS_ENTAMEA_STR-STATIN sy-vline
WA_EHSWAS_ENTAMEA_STR-STATEX sy-vline
WA_EHSWAS_ENTAMEA_STR-ANZDOC_TOTL sy-vline
WA_EHSWAS_ENTAMEA_STR-LTXT_EAN sy-vline
WA_EHSWAS_ENTAMEA_STR-PLANT_NAME sy-vline
WA_EHSWAS_ENTAMEA_STR-TTIME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.