ABAP Select data from SAP table EHSBS_DFIOT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHSBS_DFIOT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHSBS_DFIOT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHSBS_DFIOT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHSBS_DFIOT TYPE STANDARD TABLE OF EHSBS_DFIOT,
      WA_EHSBS_DFIOT TYPE EHSBS_DFIOT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHSBS_DFIOT> TYPE EHSBS_DFIOT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHSBS_DFIOT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHSBS_DFIOT
  INTO TABLE IT_EHSBS_DFIOT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHSBS_DFIOT
*  INTO TABLE @DATA(IT_EHSBS_DFIOT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHSBS_DFIOT INDEX 1 INTO DATA(WA_EHSBS_DFIOT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHSBS_DFIOT ASSIGNING <EHSBS_DFIOT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHSBS_DFIOT>-MARKFLG = 1.
<EHSBS_DFIOT>-SELEFLG = 1.
<EHSBS_DFIOT>-LINENO = 1.
<EHSBS_DFIOT>-LINEMOD = 1.
<EHSBS_DFIOT>-CHCOFLG = 1.
ENDLOOP.

LOOP AT IT_EHSBS_DFIOT INTO WA_EHSBS_DFIOT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHSBS_DFIOT-LOCKMOD, sy-vline,
WA_EHSBS_DFIOT-INTRFLG, sy-vline,
WA_EHSBS_DFIOT-MANDT, sy-vline,
WA_EHSBS_DFIOT-RECN, sy-vline,
WA_EHSBS_DFIOT-ACTN, sy-vline,
WA_EHSBS_DFIOT-VALFR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHSBS_DFIOT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHSBS_DFIOT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHSBS_DFIOT INTO WA_EHSBS_DFIOT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RECN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHSBS_DFIOT-RECN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSBS_DFIOT-RECN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ACTN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHSBS_DFIOT-ACTN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSBS_DFIOT-ACTN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHSBS_DFIOT-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSBS_DFIOT-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OWNID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHSBS_DFIOT-OWNID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSBS_DFIOT-OWNID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNROOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHSBS_DFIOT-RECNROOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSBS_DFIOT-RECNROOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNMST CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHSBS_DFIOT-RECNMST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSBS_DFIOT-RECNMST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_EHSBS_DFIOT-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSBS_DFIOT-LANGU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOKNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHSBS_DFIOT-DOKNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHSBS_DFIOT-DOKNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHSBS_DFIOT_STR,
MARKFLG TYPE STRING,
SELEFLG TYPE STRING,
LINENO TYPE STRING,
LINEMOD TYPE STRING,
CHCOFLG TYPE STRING,
LOCKMOD TYPE STRING,
INTRFLG TYPE STRING,
MANDT TYPE STRING,
RECN TYPE STRING,
ACTN TYPE STRING,
VALFR TYPE STRING,
VALTO TYPE STRING,
AENNR TYPE STRING,
DELFLG TYPE STRING,
PARKFLG TYPE STRING,
CRDAT TYPE STRING,
CRNAM TYPE STRING,
UPDDAT TYPE STRING,
UPDNAM TYPE STRING,
SRSID TYPE STRING,
OWNID TYPE STRING,
RECNROOT TYPE STRING,
NAMEMST TYPE STRING,
RECNMST TYPE STRING,
TEXTCAT TYPE STRING,
ORD TYPE STRING,
LANGU TYPE STRING,
HEADER TYPE STRING,
LTXTFLG TYPE STRING,
FORMATFLG TYPE STRING,
DOKAR TYPE STRING,
DOKNR TYPE STRING,
DOKVR TYPE STRING,
DOKTL TYPE STRING,
DOCDATE TYPE STRING,
TEXTNAM TYPE STRING,
LTXTUPD TYPE STRING,
PREPFLG TYPE STRING,
SHOWONLYFLG TYPE STRING,
OBJECTTYPE TYPE STRING,
OBJECT TYPE STRING,
MASTEROBJECTTYPE TYPE STRING,
MASTEROBJECT TYPE STRING,
OBJECTNAM TYPE STRING,
MASTEROBJECTNAM TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHSBS_DFIOT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHSBS_DFIOT_STR-MARKFLG sy-vline
WA_EHSBS_DFIOT_STR-SELEFLG sy-vline
WA_EHSBS_DFIOT_STR-LINENO sy-vline
WA_EHSBS_DFIOT_STR-LINEMOD sy-vline
WA_EHSBS_DFIOT_STR-CHCOFLG sy-vline
WA_EHSBS_DFIOT_STR-LOCKMOD sy-vline
WA_EHSBS_DFIOT_STR-INTRFLG sy-vline
WA_EHSBS_DFIOT_STR-MANDT sy-vline
WA_EHSBS_DFIOT_STR-RECN sy-vline
WA_EHSBS_DFIOT_STR-ACTN sy-vline
WA_EHSBS_DFIOT_STR-VALFR sy-vline
WA_EHSBS_DFIOT_STR-VALTO sy-vline
WA_EHSBS_DFIOT_STR-AENNR sy-vline
WA_EHSBS_DFIOT_STR-DELFLG sy-vline
WA_EHSBS_DFIOT_STR-PARKFLG sy-vline
WA_EHSBS_DFIOT_STR-CRDAT sy-vline
WA_EHSBS_DFIOT_STR-CRNAM sy-vline
WA_EHSBS_DFIOT_STR-UPDDAT sy-vline
WA_EHSBS_DFIOT_STR-UPDNAM sy-vline
WA_EHSBS_DFIOT_STR-SRSID sy-vline
WA_EHSBS_DFIOT_STR-OWNID sy-vline
WA_EHSBS_DFIOT_STR-RECNROOT sy-vline
WA_EHSBS_DFIOT_STR-NAMEMST sy-vline
WA_EHSBS_DFIOT_STR-RECNMST sy-vline
WA_EHSBS_DFIOT_STR-TEXTCAT sy-vline
WA_EHSBS_DFIOT_STR-ORD sy-vline
WA_EHSBS_DFIOT_STR-LANGU sy-vline
WA_EHSBS_DFIOT_STR-HEADER sy-vline
WA_EHSBS_DFIOT_STR-LTXTFLG sy-vline
WA_EHSBS_DFIOT_STR-FORMATFLG sy-vline
WA_EHSBS_DFIOT_STR-DOKAR sy-vline
WA_EHSBS_DFIOT_STR-DOKNR sy-vline
WA_EHSBS_DFIOT_STR-DOKVR sy-vline
WA_EHSBS_DFIOT_STR-DOKTL sy-vline
WA_EHSBS_DFIOT_STR-DOCDATE sy-vline
WA_EHSBS_DFIOT_STR-TEXTNAM sy-vline
WA_EHSBS_DFIOT_STR-LTXTUPD sy-vline
WA_EHSBS_DFIOT_STR-PREPFLG sy-vline
WA_EHSBS_DFIOT_STR-SHOWONLYFLG sy-vline
WA_EHSBS_DFIOT_STR-OBJECTTYPE sy-vline
WA_EHSBS_DFIOT_STR-OBJECT sy-vline
WA_EHSBS_DFIOT_STR-MASTEROBJECTTYPE sy-vline
WA_EHSBS_DFIOT_STR-MASTEROBJECT sy-vline
WA_EHSBS_DFIOT_STR-OBJECTNAM sy-vline
WA_EHSBS_DFIOT_STR-MASTEROBJECTNAM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.