ABAP Select data from SAP table EHPRCS_UA_UC_USE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHPRCS_UA_UC_USE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHPRCS_UA_UC_USE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHPRCS_UA_UC_USE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHPRCS_UA_UC_USE TYPE STANDARD TABLE OF EHPRCS_UA_UC_USE,
      WA_EHPRCS_UA_UC_USE TYPE EHPRCS_UA_UC_USE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHPRCS_UA_UC_USE> TYPE EHPRCS_UA_UC_USE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHPRCS_UA_UC_USE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHPRCS_UA_UC_USE
  INTO TABLE IT_EHPRCS_UA_UC_USE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHPRCS_UA_UC_USE
*  INTO TABLE @DATA(IT_EHPRCS_UA_UC_USE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHPRCS_UA_UC_USE INDEX 1 INTO DATA(WA_EHPRCS_UA_UC_USE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHPRCS_UA_UC_USE ASSIGNING <EHPRCS_UA_UC_USE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHPRCS_UA_UC_USE>-ERRORMODE = 1.
<EHPRCS_UA_UC_USE>-ERRORINFO = 1.
<EHPRCS_UA_UC_USE>-ERRORCLASS = 1.
<EHPRCS_UA_UC_USE>-ERRORPARAM = 1.
<EHPRCS_UA_UC_USE>-LOGLOCKMOD = 1.
ENDLOOP.

LOOP AT IT_EHPRCS_UA_UC_USE INTO WA_EHPRCS_UA_UC_USE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHPRCS_UA_UC_USE-EXTINFO, sy-vline,
WA_EHPRCS_UA_UC_USE-LINEMOD, sy-vline,
WA_EHPRCS_UA_UC_USE-RECN, sy-vline,
WA_EHPRCS_UA_UC_USE-RECNVA, sy-vline,
WA_EHPRCS_UA_UC_USE-RECNVH, sy-vline,
WA_EHPRCS_UA_UC_USE-MUG_CODE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHPRCS_UA_UC_USE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHPRCS_UA_UC_USE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHPRCS_UA_UC_USE INTO WA_EHPRCS_UA_UC_USE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RECN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHPRCS_UA_UC_USE-RECN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_UA_UC_USE-RECN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNVA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHPRCS_UA_UC_USE-RECNVA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_UA_UC_USE-RECNVA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNVH CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHPRCS_UA_UC_USE-RECNVH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_UA_UC_USE-RECNVH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CUST_NR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHPRCS_UA_UC_USE-CUST_NR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_UA_UC_USE-CUST_NR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MAT_NR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EHPRCS_UA_UC_USE-MAT_NR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_UA_UC_USE-MAT_NR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHPRCS_UA_UC_USE_STR,
ERRORMODE TYPE STRING,
ERRORINFO TYPE STRING,
ERRORCLASS TYPE STRING,
ERRORPARAM TYPE STRING,
LOGLOCKMOD TYPE STRING,
EXTINFO TYPE STRING,
LINEMOD TYPE STRING,
RECN TYPE STRING,
RECNVA TYPE STRING,
RECNVH TYPE STRING,
MUG_CODE TYPE STRING,
SOU_CODE TYPE STRING,
PC_CODE TYPE STRING,
PROC_CODE TYPE STRING,
ARC_CODE TYPE STRING,
ERC_CODE TYPE STRING,
CUST_NR TYPE STRING,
MAT_NR TYPE STRING,
MUG_TOOLTIP TYPE STRING,
SOU_TOOLTIP TYPE STRING,
PC_TOOLTIP TYPE STRING,
PROC_TOOLTIP TYPE STRING,
ARC_TOOLTIP TYPE STRING,
ERC_TOOLTIP TYPE STRING,
EVALSTATUS_TEXT TYPE STRING,
EVALSTATUS TYPE STRING,
OWNUSE_TEXT TYPE STRING,
OWNUSE TYPE STRING,
STANDARDUSE_TEXT TYPE STRING,
STANDARDUSE TYPE STRING,
REGSTATUS_TEXT TYPE STRING,
REGSTATUS TYPE STRING,
STATUSJUST TYPE STRING,
LINKGROUP_ICON TYPE STRING,
LINKGROUP_ICON_TOOLTIP TYPE STRING,
FLG_LINKTOUSE TYPE STRING,
STATUS_ICON TYPE STRING,
STATUS_ICON_LINK TYPE STRING,
STATUS_ICON_IMG_REF TYPE STRING,
FLG_LINKTOUSE_TOOLTIP TYPE STRING,
STATUS_ICON_TOOLTIP TYPE STRING,
INPUT_CHECK_VALID TYPE STRING,
INPUT_CHECK_TOOLTIP TYPE STRING,
INPUT_CHECK_ICON TYPE STRING,
SHORT_TITLE TYPE STRING,
LINKTOUSE_REMARK TYPE STRING,
EEW_PRC_UA_UC_USE TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHPRCS_UA_UC_USE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHPRCS_UA_UC_USE_STR-ERRORMODE sy-vline
WA_EHPRCS_UA_UC_USE_STR-ERRORINFO sy-vline
WA_EHPRCS_UA_UC_USE_STR-ERRORCLASS sy-vline
WA_EHPRCS_UA_UC_USE_STR-ERRORPARAM sy-vline
WA_EHPRCS_UA_UC_USE_STR-LOGLOCKMOD sy-vline
WA_EHPRCS_UA_UC_USE_STR-EXTINFO sy-vline
WA_EHPRCS_UA_UC_USE_STR-LINEMOD sy-vline
WA_EHPRCS_UA_UC_USE_STR-RECN sy-vline
WA_EHPRCS_UA_UC_USE_STR-RECNVA sy-vline
WA_EHPRCS_UA_UC_USE_STR-RECNVH sy-vline
WA_EHPRCS_UA_UC_USE_STR-MUG_CODE sy-vline
WA_EHPRCS_UA_UC_USE_STR-SOU_CODE sy-vline
WA_EHPRCS_UA_UC_USE_STR-PC_CODE sy-vline
WA_EHPRCS_UA_UC_USE_STR-PROC_CODE sy-vline
WA_EHPRCS_UA_UC_USE_STR-ARC_CODE sy-vline
WA_EHPRCS_UA_UC_USE_STR-ERC_CODE sy-vline
WA_EHPRCS_UA_UC_USE_STR-CUST_NR sy-vline
WA_EHPRCS_UA_UC_USE_STR-MAT_NR sy-vline
WA_EHPRCS_UA_UC_USE_STR-MUG_TOOLTIP sy-vline
WA_EHPRCS_UA_UC_USE_STR-SOU_TOOLTIP sy-vline
WA_EHPRCS_UA_UC_USE_STR-PC_TOOLTIP sy-vline
WA_EHPRCS_UA_UC_USE_STR-PROC_TOOLTIP sy-vline
WA_EHPRCS_UA_UC_USE_STR-ARC_TOOLTIP sy-vline
WA_EHPRCS_UA_UC_USE_STR-ERC_TOOLTIP sy-vline
WA_EHPRCS_UA_UC_USE_STR-EVALSTATUS_TEXT sy-vline
WA_EHPRCS_UA_UC_USE_STR-EVALSTATUS sy-vline
WA_EHPRCS_UA_UC_USE_STR-OWNUSE_TEXT sy-vline
WA_EHPRCS_UA_UC_USE_STR-OWNUSE sy-vline
WA_EHPRCS_UA_UC_USE_STR-STANDARDUSE_TEXT sy-vline
WA_EHPRCS_UA_UC_USE_STR-STANDARDUSE sy-vline
WA_EHPRCS_UA_UC_USE_STR-REGSTATUS_TEXT sy-vline
WA_EHPRCS_UA_UC_USE_STR-REGSTATUS sy-vline
WA_EHPRCS_UA_UC_USE_STR-STATUSJUST sy-vline
WA_EHPRCS_UA_UC_USE_STR-LINKGROUP_ICON sy-vline
WA_EHPRCS_UA_UC_USE_STR-LINKGROUP_ICON_TOOLTIP sy-vline
WA_EHPRCS_UA_UC_USE_STR-FLG_LINKTOUSE sy-vline
WA_EHPRCS_UA_UC_USE_STR-STATUS_ICON sy-vline
WA_EHPRCS_UA_UC_USE_STR-STATUS_ICON_LINK sy-vline
WA_EHPRCS_UA_UC_USE_STR-STATUS_ICON_IMG_REF sy-vline
WA_EHPRCS_UA_UC_USE_STR-FLG_LINKTOUSE_TOOLTIP sy-vline
WA_EHPRCS_UA_UC_USE_STR-STATUS_ICON_TOOLTIP sy-vline
WA_EHPRCS_UA_UC_USE_STR-INPUT_CHECK_VALID sy-vline
WA_EHPRCS_UA_UC_USE_STR-INPUT_CHECK_TOOLTIP sy-vline
WA_EHPRCS_UA_UC_USE_STR-INPUT_CHECK_ICON sy-vline
WA_EHPRCS_UA_UC_USE_STR-SHORT_TITLE sy-vline
WA_EHPRCS_UA_UC_USE_STR-LINKTOUSE_REMARK sy-vline
WA_EHPRCS_UA_UC_USE_STR-EEW_PRC_UA_UC_USE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.