ABAP Select data from SAP table EHPRCS_SIM_OUT_STRUCT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHPRCS_SIM_OUT_STRUCT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHPRCS_SIM_OUT_STRUCT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHPRCS_SIM_OUT_STRUCT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHPRCS_SIM_OUT_STRUCT TYPE STANDARD TABLE OF EHPRCS_SIM_OUT_STRUCT,
      WA_EHPRCS_SIM_OUT_STRUCT TYPE EHPRCS_SIM_OUT_STRUCT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHPRCS_SIM_OUT_STRUCT> TYPE EHPRCS_SIM_OUT_STRUCT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHPRCS_SIM_OUT_STRUCT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHPRCS_SIM_OUT_STRUCT
  INTO TABLE IT_EHPRCS_SIM_OUT_STRUCT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHPRCS_SIM_OUT_STRUCT
*  INTO TABLE @DATA(IT_EHPRCS_SIM_OUT_STRUCT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHPRCS_SIM_OUT_STRUCT INDEX 1 INTO DATA(WA_EHPRCS_SIM_OUT_STRUCT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHPRCS_SIM_OUT_STRUCT ASSIGNING <EHPRCS_SIM_OUT_STRUCT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHPRCS_SIM_OUT_STRUCT>-NODE_KEY = 1.
<EHPRCS_SIM_OUT_STRUCT>-PARENT_NODE_KEY = 1.
<EHPRCS_SIM_OUT_STRUCT>-NEXT_NODE_KEY = 1.
<EHPRCS_SIM_OUT_STRUCT>-ORD = 1.
<EHPRCS_SIM_OUT_STRUCT>-NODE_TYPE = 1.
ENDLOOP.

LOOP AT IT_EHPRCS_SIM_OUT_STRUCT INTO WA_EHPRCS_SIM_OUT_STRUCT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHPRCS_SIM_OUT_STRUCT-SPEC_TYPE, sy-vline,
WA_EHPRCS_SIM_OUT_STRUCT-ID, sy-vline,
WA_EHPRCS_SIM_OUT_STRUCT-SPEC_ID, sy-vline,
WA_EHPRCS_SIM_OUT_STRUCT-RECN, sy-vline,
WA_EHPRCS_SIM_OUT_STRUCT-ACTN, sy-vline,
WA_EHPRCS_SIM_OUT_STRUCT-GROUP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHPRCS_SIM_OUT_STRUCT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHPRCS_SIM_OUT_STRUCT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHPRCS_SIM_OUT_STRUCT INTO WA_EHPRCS_SIM_OUT_STRUCT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit SPEC1, internal->external for field SPEC_ID CALL FUNCTION 'CONVERSION_EXIT_SPEC1_OUTPUT' EXPORTING input = WA_EHPRCS_SIM_OUT_STRUCT-SPEC_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_SIM_OUT_STRUCT-SPEC_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHPRCS_SIM_OUT_STRUCT-RECN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_SIM_OUT_STRUCT-RECN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ACTN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHPRCS_SIM_OUT_STRUCT-ACTN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_SIM_OUT_STRUCT-ACTN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SUPPL_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHPRCS_SIM_OUT_STRUCT-SUPPL_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_SIM_OUT_STRUCT-SUPPL_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNVA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHPRCS_SIM_OUT_STRUCT-RECNVA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_SIM_OUT_STRUCT-RECNVA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ACTNVA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHPRCS_SIM_OUT_STRUCT-ACTNVA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_SIM_OUT_STRUCT-ACTNVA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNVP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHPRCS_SIM_OUT_STRUCT-RECNVP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_SIM_OUT_STRUCT-RECNVP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ACTNVP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHPRCS_SIM_OUT_STRUCT-ACTNVP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_SIM_OUT_STRUCT-ACTNVP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MASS_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EHPRCS_SIM_OUT_STRUCT-MASS_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_SIM_OUT_STRUCT-MASS_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MAT_NO CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EHPRCS_SIM_OUT_STRUCT-MAT_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_SIM_OUT_STRUCT-MAT_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MAT_NO_COMP CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EHPRCS_SIM_OUT_STRUCT-MAT_NO_COMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_SIM_OUT_STRUCT-MAT_NO_COMP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUANT_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EHPRCS_SIM_OUT_STRUCT-QUANT_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_SIM_OUT_STRUCT-QUANT_UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHPRCS_SIM_OUT_STRUCT_STR,
NODE_KEY TYPE STRING,
PARENT_NODE_KEY TYPE STRING,
NEXT_NODE_KEY TYPE STRING,
ORD TYPE STRING,
NODE_TYPE TYPE STRING,
SPEC_TYPE TYPE STRING,
ID TYPE STRING,
SPEC_ID TYPE STRING,
RECN TYPE STRING,
ACTN TYPE STRING,
GROUP TYPE STRING,
FLG_PREFERRED TYPE STRING,
SUPPL_NO TYPE STRING,
SUPPL_NAME TYPE STRING,
RECNVA TYPE STRING,
ACTNVA TYPE STRING,
RECNVP TYPE STRING,
ACTNVP TYPE STRING,
CALC_MASS TYPE STRING,
MASS_UNIT TYPE STRING,
FLG_AMPL_HEAD TYPE STRING,
FLG_MULT_SUPPL TYPE STRING,
FLG_PLANTS_ONLY TYPE STRING,
PROPERTY TYPE STRING,
LEVEL TYPE STRING,
VARIANT TYPE STRING,
PLANT TYPE STRING,
PLANT_NAME TYPE STRING,
USAGE TYPE STRING,
ALTERNATE TYPE STRING,
SUPPLIER_LIST TYPE STRING,
CUSTOMER TYPE STRING,
FLG_HAS_COMP TYPE STRING,
MAT_NO TYPE STRING,
MAT_NO_COMP TYPE STRING,
IDENT_1 TYPE STRING,
IDENT_2 TYPE STRING,
IDENT_3 TYPE STRING,
QUANT_AVG_TXT TYPE STRING,
QUANT_UNIT TYPE STRING,
EXIST_ICON TYPE STRING,
CHECK_STATUS_ICON_1 TYPE STRING,
CHECK_STATUS_ICON_2 TYPE STRING,
CHECK_STATUS_ICON_3 TYPE STRING,
CHECK_STATUS_ICON_4 TYPE STRING,
CHECK_STATUS_ICON_5 TYPE STRING,
CHECK_STATUS_ICON_6 TYPE STRING,
CHECK_STATUS_ICON_7 TYPE STRING,
CHECK_STATUS_ICON_8 TYPE STRING,
CHECK_STATUS_ICON_9 TYPE STRING,
CHECK_STATUS_ICON_10 TYPE STRING,
CUST_ADD_INFO_1 TYPE STRING,
CUST_ADD_INFO_2 TYPE STRING,
CUST_ADD_INFO_3 TYPE STRING,
CUST_ADD_INFO_4 TYPE STRING,
CUST_ADD_INFO_5 TYPE STRING,
COLOR TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHPRCS_SIM_OUT_STRUCT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-NODE_KEY sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-PARENT_NODE_KEY sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-NEXT_NODE_KEY sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-ORD sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-NODE_TYPE sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-SPEC_TYPE sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-ID sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-SPEC_ID sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-RECN sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-ACTN sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-GROUP sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-FLG_PREFERRED sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-SUPPL_NO sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-SUPPL_NAME sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-RECNVA sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-ACTNVA sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-RECNVP sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-ACTNVP sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-CALC_MASS sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-MASS_UNIT sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-FLG_AMPL_HEAD sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-FLG_MULT_SUPPL sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-FLG_PLANTS_ONLY sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-PROPERTY sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-LEVEL sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-VARIANT sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-PLANT sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-PLANT_NAME sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-USAGE sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-ALTERNATE sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-SUPPLIER_LIST sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-CUSTOMER sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-FLG_HAS_COMP sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-MAT_NO sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-MAT_NO_COMP sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-IDENT_1 sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-IDENT_2 sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-IDENT_3 sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-QUANT_AVG_TXT sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-QUANT_UNIT sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-EXIST_ICON sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-CHECK_STATUS_ICON_1 sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-CHECK_STATUS_ICON_2 sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-CHECK_STATUS_ICON_3 sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-CHECK_STATUS_ICON_4 sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-CHECK_STATUS_ICON_5 sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-CHECK_STATUS_ICON_6 sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-CHECK_STATUS_ICON_7 sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-CHECK_STATUS_ICON_8 sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-CHECK_STATUS_ICON_9 sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-CHECK_STATUS_ICON_10 sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-CUST_ADD_INFO_1 sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-CUST_ADD_INFO_2 sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-CUST_ADD_INFO_3 sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-CUST_ADD_INFO_4 sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-CUST_ADD_INFO_5 sy-vline
WA_EHPRCS_SIM_OUT_STRUCT_STR-COLOR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.