ABAP Select data from SAP table EHPRCS_KEY_EP_COV_CHECK into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHPRCS_KEY_EP_COV_CHECK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHPRCS_KEY_EP_COV_CHECK. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHPRCS_KEY_EP_COV_CHECK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHPRCS_KEY_EP_COV_CHECK TYPE STANDARD TABLE OF EHPRCS_KEY_EP_COV_CHECK,
      WA_EHPRCS_KEY_EP_COV_CHECK TYPE EHPRCS_KEY_EP_COV_CHECK,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHPRCS_KEY_EP_COV_CHECK> TYPE EHPRCS_KEY_EP_COV_CHECK.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHPRCS_KEY_EP_COV_CHECK.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHPRCS_KEY_EP_COV_CHECK
  INTO TABLE IT_EHPRCS_KEY_EP_COV_CHECK.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHPRCS_KEY_EP_COV_CHECK
*  INTO TABLE @DATA(IT_EHPRCS_KEY_EP_COV_CHECK2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHPRCS_KEY_EP_COV_CHECK INDEX 1 INTO DATA(WA_EHPRCS_KEY_EP_COV_CHECK2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHPRCS_KEY_EP_COV_CHECK ASSIGNING <EHPRCS_KEY_EP_COV_CHECK>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHPRCS_KEY_EP_COV_CHECK>-RECN = 1.
<EHPRCS_KEY_EP_COV_CHECK>-CHAPTER_CODE = 1.
<EHPRCS_KEY_EP_COV_CHECK>-EPTYPE = 1.
<EHPRCS_KEY_EP_COV_CHECK>-COVERING_STUDY = 1.
<EHPRCS_KEY_EP_COV_CHECK>-PURPOSE = 1.
ENDLOOP.

LOOP AT IT_EHPRCS_KEY_EP_COV_CHECK INTO WA_EHPRCS_KEY_EP_COV_CHECK.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHPRCS_KEY_EP_COV_CHECK-ROBUST_SUMMARY, sy-vline,
WA_EHPRCS_KEY_EP_COV_CHECK-EPNAM, sy-vline,
WA_EHPRCS_KEY_EP_COV_CHECK-STATUS_CATPIN, sy-vline,
WA_EHPRCS_KEY_EP_COV_CHECK-STATUS_PHRID, sy-vline,
WA_EHPRCS_KEY_EP_COV_CHECK-OWNING_LE, sy-vline,
WA_EHPRCS_KEY_EP_COV_CHECK-EXT_OWNER_BP_CODE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHPRCS_KEY_EP_COV_CHECK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHPRCS_KEY_EP_COV_CHECK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHPRCS_KEY_EP_COV_CHECK INTO WA_EHPRCS_KEY_EP_COV_CHECK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RECN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHPRCS_KEY_EP_COV_CHECK-RECN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_KEY_EP_COV_CHECK-RECN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CHRI3, internal->external for field STATUS_PHRID CALL FUNCTION 'CONVERSION_EXIT_CHRI3_OUTPUT' EXPORTING input = WA_EHPRCS_KEY_EP_COV_CHECK-STATUS_PHRID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_KEY_EP_COV_CHECK-STATUS_PHRID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EXT_OWNER_BP_CODE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHPRCS_KEY_EP_COV_CHECK-EXT_OWNER_BP_CODE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_KEY_EP_COV_CHECK-EXT_OWNER_BP_CODE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EXT_OWNER_S_CODE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHPRCS_KEY_EP_COV_CHECK-EXT_OWNER_S_CODE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_KEY_EP_COV_CHECK-EXT_OWNER_S_CODE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHPRCS_KEY_EP_COV_CHECK_STR,
RECN TYPE STRING,
CHAPTER_CODE TYPE STRING,
EPTYPE TYPE STRING,
COVERING_STUDY TYPE STRING,
PURPOSE TYPE STRING,
ROBUST_SUMMARY TYPE STRING,
EPNAM TYPE STRING,
STATUS_CATPIN TYPE STRING,
STATUS_PHRID TYPE STRING,
OWNING_LE TYPE STRING,
EXT_OWNER_BP_CODE TYPE STRING,
EXT_OWNER_S_CODE TYPE STRING,
IUCLID_LINK TYPE STRING,
IUCLID_DOC TYPE STRING,
DMS_LINK TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHPRCS_KEY_EP_COV_CHECK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHPRCS_KEY_EP_COV_CHECK_STR-RECN sy-vline
WA_EHPRCS_KEY_EP_COV_CHECK_STR-CHAPTER_CODE sy-vline
WA_EHPRCS_KEY_EP_COV_CHECK_STR-EPTYPE sy-vline
WA_EHPRCS_KEY_EP_COV_CHECK_STR-COVERING_STUDY sy-vline
WA_EHPRCS_KEY_EP_COV_CHECK_STR-PURPOSE sy-vline
WA_EHPRCS_KEY_EP_COV_CHECK_STR-ROBUST_SUMMARY sy-vline
WA_EHPRCS_KEY_EP_COV_CHECK_STR-EPNAM sy-vline
WA_EHPRCS_KEY_EP_COV_CHECK_STR-STATUS_CATPIN sy-vline
WA_EHPRCS_KEY_EP_COV_CHECK_STR-STATUS_PHRID sy-vline
WA_EHPRCS_KEY_EP_COV_CHECK_STR-OWNING_LE sy-vline
WA_EHPRCS_KEY_EP_COV_CHECK_STR-EXT_OWNER_BP_CODE sy-vline
WA_EHPRCS_KEY_EP_COV_CHECK_STR-EXT_OWNER_S_CODE sy-vline
WA_EHPRCS_KEY_EP_COV_CHECK_STR-IUCLID_LINK sy-vline
WA_EHPRCS_KEY_EP_COV_CHECK_STR-IUCLID_DOC sy-vline
WA_EHPRCS_KEY_EP_COV_CHECK_STR-DMS_LINK sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.