ABAP Select data from SAP table EHPRCS_IPCX_SUB_CAT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHPRCS_IPCX_SUB_CAT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHPRCS_IPCX_SUB_CAT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHPRCS_IPCX_SUB_CAT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHPRCS_IPCX_SUB_CAT TYPE STANDARD TABLE OF EHPRCS_IPCX_SUB_CAT,
      WA_EHPRCS_IPCX_SUB_CAT TYPE EHPRCS_IPCX_SUB_CAT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHPRCS_IPCX_SUB_CAT> TYPE EHPRCS_IPCX_SUB_CAT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHPRCS_IPCX_SUB_CAT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHPRCS_IPCX_SUB_CAT
  INTO TABLE IT_EHPRCS_IPCX_SUB_CAT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHPRCS_IPCX_SUB_CAT
*  INTO TABLE @DATA(IT_EHPRCS_IPCX_SUB_CAT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHPRCS_IPCX_SUB_CAT INDEX 1 INTO DATA(WA_EHPRCS_IPCX_SUB_CAT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHPRCS_IPCX_SUB_CAT ASSIGNING <EHPRCS_IPCX_SUB_CAT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHPRCS_IPCX_SUB_CAT>-NAME = 1.
<EHPRCS_IPCX_SUB_CAT>-SUB_CAT_COMMENT = 1.
<EHPRCS_IPCX_SUB_CAT>-DESCRIPTION_OF_USE = 1.
<EHPRCS_IPCX_SUB_CAT>-SUBSTANCE = 1.
<EHPRCS_IPCX_SUB_CAT>-AMOUNT = 1.
ENDLOOP.

LOOP AT IT_EHPRCS_IPCX_SUB_CAT INTO WA_EHPRCS_IPCX_SUB_CAT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHPRCS_IPCX_SUB_CAT-UOM, sy-vline,
WA_EHPRCS_IPCX_SUB_CAT-VALUE, sy-vline,
WA_EHPRCS_IPCX_SUB_CAT-THRESHOLD, sy-vline,
WA_EHPRCS_IPCX_SUB_CAT-THRESHOLD, sy-vline,
WA_EHPRCS_IPCX_SUB_CAT-INTENTIONALLY_ADDED, sy-vline,
WA_EHPRCS_IPCX_SUB_CAT-OVER_THRESHOLD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHPRCS_IPCX_SUB_CAT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHPRCS_IPCX_SUB_CAT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHPRCS_IPCX_SUB_CAT INTO WA_EHPRCS_IPCX_SUB_CAT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHPRCS_IPCX_SUB_CAT_STR,
NAME TYPE STRING,
SUB_CAT_COMMENT TYPE STRING,
DESCRIPTION_OF_USE TYPE STRING,
SUBSTANCE TYPE STRING,
AMOUNT TYPE STRING,
UOM TYPE STRING,
VALUE TYPE STRING,
THRESHOLD TYPE STRING,
THRESHOLD TYPE STRING,
INTENTIONALLY_ADDED TYPE STRING,
OVER_THRESHOLD TYPE STRING,
CONCENTRATION TYPE STRING,
SUB_CAT_EXEMP_LIST TYPE STRING,
EXEMPTION_LIST_ID TYPE STRING,
UID_IDENTITY TYPE STRING,
UID_AUTHORITY TYPE STRING,
EXEMPTION TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHPRCS_IPCX_SUB_CAT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHPRCS_IPCX_SUB_CAT_STR-NAME sy-vline
WA_EHPRCS_IPCX_SUB_CAT_STR-SUB_CAT_COMMENT sy-vline
WA_EHPRCS_IPCX_SUB_CAT_STR-DESCRIPTION_OF_USE sy-vline
WA_EHPRCS_IPCX_SUB_CAT_STR-SUBSTANCE sy-vline
WA_EHPRCS_IPCX_SUB_CAT_STR-AMOUNT sy-vline
WA_EHPRCS_IPCX_SUB_CAT_STR-UOM sy-vline
WA_EHPRCS_IPCX_SUB_CAT_STR-VALUE sy-vline
WA_EHPRCS_IPCX_SUB_CAT_STR-THRESHOLD sy-vline
WA_EHPRCS_IPCX_SUB_CAT_STR-THRESHOLD sy-vline
WA_EHPRCS_IPCX_SUB_CAT_STR-INTENTIONALLY_ADDED sy-vline
WA_EHPRCS_IPCX_SUB_CAT_STR-OVER_THRESHOLD sy-vline
WA_EHPRCS_IPCX_SUB_CAT_STR-CONCENTRATION sy-vline
WA_EHPRCS_IPCX_SUB_CAT_STR-SUB_CAT_EXEMP_LIST sy-vline
WA_EHPRCS_IPCX_SUB_CAT_STR-EXEMPTION_LIST_ID sy-vline
WA_EHPRCS_IPCX_SUB_CAT_STR-UID_IDENTITY sy-vline
WA_EHPRCS_IPCX_SUB_CAT_STR-UID_AUTHORITY sy-vline
WA_EHPRCS_IPCX_SUB_CAT_STR-EXEMPTION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.