ABAP Select data from SAP table EHPRCS_EXP_ALL_SUBPROF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHPRCS_EXP_ALL_SUBPROF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHPRCS_EXP_ALL_SUBPROF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHPRCS_EXP_ALL_SUBPROF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHPRCS_EXP_ALL_SUBPROF TYPE STANDARD TABLE OF EHPRCS_EXP_ALL_SUBPROF,
      WA_EHPRCS_EXP_ALL_SUBPROF TYPE EHPRCS_EXP_ALL_SUBPROF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHPRCS_EXP_ALL_SUBPROF> TYPE EHPRCS_EXP_ALL_SUBPROF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHPRCS_EXP_ALL_SUBPROF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHPRCS_EXP_ALL_SUBPROF
  INTO TABLE IT_EHPRCS_EXP_ALL_SUBPROF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHPRCS_EXP_ALL_SUBPROF
*  INTO TABLE @DATA(IT_EHPRCS_EXP_ALL_SUBPROF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHPRCS_EXP_ALL_SUBPROF INDEX 1 INTO DATA(WA_EHPRCS_EXP_ALL_SUBPROF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHPRCS_EXP_ALL_SUBPROF ASSIGNING <EHPRCS_EXP_ALL_SUBPROF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHPRCS_EXP_ALL_SUBPROF>-RECN = 1.
<EHPRCS_EXP_ALL_SUBPROF>-SUBID = 1.
<EHPRCS_EXP_ALL_SUBPROF>-SUBNAME = 1.
<EHPRCS_EXP_ALL_SUBPROF>-CASNR = 1.
<EHPRCS_EXP_ALL_SUBPROF>-ECNR = 1.
ENDLOOP.

LOOP AT IT_EHPRCS_EXP_ALL_SUBPROF INTO WA_EHPRCS_EXP_ALL_SUBPROF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHPRCS_EXP_ALL_SUBPROF-RSAG, sy-vline,
WA_EHPRCS_EXP_ALL_SUBPROF-PROCSEQ, sy-vline,
WA_EHPRCS_EXP_ALL_SUBPROF-BUSINESSPRIO, sy-vline,
WA_EHPRCS_EXP_ALL_SUBPROF-MAXTOBAND_CODE, sy-vline,
WA_EHPRCS_EXP_ALL_SUBPROF-MAXTOBAND_NAME, sy-vline,
WA_EHPRCS_EXP_ALL_SUBPROF-LEADINGLEGENT_CODE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHPRCS_EXP_ALL_SUBPROF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHPRCS_EXP_ALL_SUBPROF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHPRCS_EXP_ALL_SUBPROF INTO WA_EHPRCS_EXP_ALL_SUBPROF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RECN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHPRCS_EXP_ALL_SUBPROF-RECN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_EXP_ALL_SUBPROF-RECN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SPEC1, internal->external for field SUBID CALL FUNCTION 'CONVERSION_EXIT_SPEC1_OUTPUT' EXPORTING input = WA_EHPRCS_EXP_ALL_SUBPROF-SUBID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPRCS_EXP_ALL_SUBPROF-SUBID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHPRCS_EXP_ALL_SUBPROF_STR,
RECN TYPE STRING,
SUBID TYPE STRING,
SUBNAME TYPE STRING,
CASNR TYPE STRING,
ECNR TYPE STRING,
RSAG TYPE STRING,
PROCSEQ TYPE STRING,
BUSINESSPRIO TYPE STRING,
MAXTOBAND_CODE TYPE STRING,
MAXTOBAND_NAME TYPE STRING,
LEADINGLEGENT_CODE TYPE STRING,
LEADINGLEGENT_NAME TYPE STRING,
LEADINGORGUNIT_CODE TYPE STRING,
LEADINGORGUNIT_NAME TYPE STRING,
REGDEADLINE TYPE STRING,
PHASEIN TYPE STRING,
AUTHCAND TYPE STRING,
ANNEXXIV TYPE STRING,
ANNEXXVII TYPE STRING,
ISCATEGORY TYPE STRING,
MONOMER TYPE STRING,
NOLONGERPOLY TYPE STRING,
REMARK TYPE STRING,
SUBTYPE TYPE STRING,
REG_DECISION TYPE STRING,
IUCLID_LINK TYPE STRING,
DMS_LINK TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHPRCS_EXP_ALL_SUBPROF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-RECN sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-SUBID sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-SUBNAME sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-CASNR sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-ECNR sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-RSAG sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-PROCSEQ sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-BUSINESSPRIO sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-MAXTOBAND_CODE sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-MAXTOBAND_NAME sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-LEADINGLEGENT_CODE sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-LEADINGLEGENT_NAME sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-LEADINGORGUNIT_CODE sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-LEADINGORGUNIT_NAME sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-REGDEADLINE sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-PHASEIN sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-AUTHCAND sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-ANNEXXIV sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-ANNEXXVII sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-ISCATEGORY sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-MONOMER sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-NOLONGERPOLY sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-REMARK sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-SUBTYPE sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-REG_DECISION sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-IUCLID_LINK sy-vline
WA_EHPRCS_EXP_ALL_SUBPROF_STR-DMS_LINK sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.