ABAP Select data from SAP table EHPMAD_SVT_AGIBP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHPMAD_SVT_AGIBP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHPMAD_SVT_AGIBP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHPMAD_SVT_AGIBP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHPMAD_SVT_AGIBP TYPE STANDARD TABLE OF EHPMAD_SVT_AGIBP,
      WA_EHPMAD_SVT_AGIBP TYPE EHPMAD_SVT_AGIBP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHPMAD_SVT_AGIBP> TYPE EHPMAD_SVT_AGIBP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHPMAD_SVT_AGIBP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHPMAD_SVT_AGIBP
  INTO TABLE IT_EHPMAD_SVT_AGIBP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHPMAD_SVT_AGIBP
*  INTO TABLE @DATA(IT_EHPMAD_SVT_AGIBP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHPMAD_SVT_AGIBP INDEX 1 INTO DATA(WA_EHPMAD_SVT_AGIBP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHPMAD_SVT_AGIBP ASSIGNING <EHPMAD_SVT_AGIBP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHPMAD_SVT_AGIBP>-CLIENT = 1.
<EHPMAD_SVT_AGIBP>-SVTAGGRGNITMBYBUSPROCUUID = 1.
<EHPMAD_SVT_AGIBP>-LASTCHANGEDATETIME = 1.
<EHPMAD_SVT_AGIBP>-SVTBUSINESSPROCESS = 1.
<EHPMAD_SVT_AGIBP>-SVTBUSINESSPROCESSSCENARIO = 1.
ENDLOOP.

LOOP AT IT_EHPMAD_SVT_AGIBP INTO WA_EHPMAD_SVT_AGIBP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHPMAD_SVT_AGIBP-SUBPERIODTRACKINGSTARTDATE, sy-vline,
WA_EHPMAD_SVT_AGIBP-SUBPERIODTRACKINGENDDATE, sy-vline,
WA_EHPMAD_SVT_AGIBP-PLANNEDSUBSTANCEVOLUME, sy-vline,
WA_EHPMAD_SVT_AGIBP-PLANNEDSUBSTANCEVOLUMEUNIT, sy-vline,
WA_EHPMAD_SVT_AGIBP-CONFIRMEDSUBSTANCEVOLUME, sy-vline,
WA_EHPMAD_SVT_AGIBP-CONFIRMEDSUBSTANCEVOLUMEUNIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHPMAD_SVT_AGIBP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHPMAD_SVT_AGIBP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHPMAD_SVT_AGIBP INTO WA_EHPMAD_SVT_AGIBP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EHPMAD_SVT_AGIBP-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHPMAD_SVT_AGIBP-MATERIAL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHPMAD_SVT_AGIBP_STR,
CLIENT TYPE STRING,
SVTAGGRGNITMBYBUSPROCUUID TYPE STRING,
LASTCHANGEDATETIME TYPE STRING,
SVTBUSINESSPROCESS TYPE STRING,
SVTBUSINESSPROCESSSCENARIO TYPE STRING,
SUBPERIODTRACKINGSTARTDATE TYPE STRING,
SUBPERIODTRACKINGENDDATE TYPE STRING,
PLANNEDSUBSTANCEVOLUME TYPE STRING,
PLANNEDSUBSTANCEVOLUMEUNIT TYPE STRING,
CONFIRMEDSUBSTANCEVOLUME TYPE STRING,
CONFIRMEDSUBSTANCEVOLUMEUNIT TYPE STRING,
CHMLCMPLNCINFOUUID TYPE STRING,
SVTAGGREGATIONITEMUUID TYPE STRING,
PLANT TYPE STRING,
MATERIAL TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHPMAD_SVT_AGIBP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHPMAD_SVT_AGIBP_STR-CLIENT sy-vline
WA_EHPMAD_SVT_AGIBP_STR-SVTAGGRGNITMBYBUSPROCUUID sy-vline
WA_EHPMAD_SVT_AGIBP_STR-LASTCHANGEDATETIME sy-vline
WA_EHPMAD_SVT_AGIBP_STR-SVTBUSINESSPROCESS sy-vline
WA_EHPMAD_SVT_AGIBP_STR-SVTBUSINESSPROCESSSCENARIO sy-vline
WA_EHPMAD_SVT_AGIBP_STR-SUBPERIODTRACKINGSTARTDATE sy-vline
WA_EHPMAD_SVT_AGIBP_STR-SUBPERIODTRACKINGENDDATE sy-vline
WA_EHPMAD_SVT_AGIBP_STR-PLANNEDSUBSTANCEVOLUME sy-vline
WA_EHPMAD_SVT_AGIBP_STR-PLANNEDSUBSTANCEVOLUMEUNIT sy-vline
WA_EHPMAD_SVT_AGIBP_STR-CONFIRMEDSUBSTANCEVOLUME sy-vline
WA_EHPMAD_SVT_AGIBP_STR-CONFIRMEDSUBSTANCEVOLUMEUNIT sy-vline
WA_EHPMAD_SVT_AGIBP_STR-CHMLCMPLNCINFOUUID sy-vline
WA_EHPMAD_SVT_AGIBP_STR-SVTAGGREGATIONITEMUUID sy-vline
WA_EHPMAD_SVT_AGIBP_STR-PLANT sy-vline
WA_EHPMAD_SVT_AGIBP_STR-MATERIAL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.