ABAP Select data from SAP table EHHSSS_UI_SPLNG_SAMPLE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHHSSS_UI_SPLNG_SAMPLE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHHSSS_UI_SPLNG_SAMPLE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHHSSS_UI_SPLNG_SAMPLE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHHSSS_UI_SPLNG_SAMPLE TYPE STANDARD TABLE OF EHHSSS_UI_SPLNG_SAMPLE,
      WA_EHHSSS_UI_SPLNG_SAMPLE TYPE EHHSSS_UI_SPLNG_SAMPLE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHHSSS_UI_SPLNG_SAMPLE> TYPE EHHSSS_UI_SPLNG_SAMPLE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHHSSS_UI_SPLNG_SAMPLE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHHSSS_UI_SPLNG_SAMPLE
  INTO TABLE IT_EHHSSS_UI_SPLNG_SAMPLE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHHSSS_UI_SPLNG_SAMPLE
*  INTO TABLE @DATA(IT_EHHSSS_UI_SPLNG_SAMPLE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHHSSS_UI_SPLNG_SAMPLE INDEX 1 INTO DATA(WA_EHHSSS_UI_SPLNG_SAMPLE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHHSSS_UI_SPLNG_SAMPLE ASSIGNING <EHHSSS_UI_SPLNG_SAMPLE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHHSSS_UI_SPLNG_SAMPLE>-KEY = 1.
<EHHSSS_UI_SPLNG_SAMPLE>-PARENT_KEY = 1.
<EHHSSS_UI_SPLNG_SAMPLE>-ROOT_KEY = 1.
<EHHSSS_UI_SPLNG_SAMPLE>-DATETIME_CR = 1.
<EHHSSS_UI_SPLNG_SAMPLE>-USER_ID_CR = 1.
ENDLOOP.

LOOP AT IT_EHHSSS_UI_SPLNG_SAMPLE INTO WA_EHHSSS_UI_SPLNG_SAMPLE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHHSSS_UI_SPLNG_SAMPLE-DATETIME_CH, sy-vline,
WA_EHHSSS_UI_SPLNG_SAMPLE-USER_ID_CH, sy-vline,
WA_EHHSSS_UI_SPLNG_SAMPLE-BLANK_INDICATOR, sy-vline,
WA_EHHSSS_UI_SPLNG_SAMPLE-BLANK_TYPE, sy-vline,
WA_EHHSSS_UI_SPLNG_SAMPLE-PERSON_SAMPLED, sy-vline,
WA_EHHSSS_UI_SPLNG_SAMPLE-MEDIA_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHHSSS_UI_SPLNG_SAMPLE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHHSSS_UI_SPLNG_SAMPLE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHHSSS_UI_SPLNG_SAMPLE INTO WA_EHHSSS_UI_SPLNG_SAMPLE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TSTLC, internal->external for field DATETIME_CR CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_EHHSSS_UI_SPLNG_SAMPLE-DATETIME_CR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_UI_SPLNG_SAMPLE-DATETIME_CR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field DATETIME_CH CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_EHHSSS_UI_SPLNG_SAMPLE-DATETIME_CH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_UI_SPLNG_SAMPLE-DATETIME_CH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PARID, internal->external for field PERSON_SAMPLED CALL FUNCTION 'CONVERSION_EXIT_PARID_OUTPUT' EXPORTING input = WA_EHHSSS_UI_SPLNG_SAMPLE-PERSON_SAMPLED IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_UI_SPLNG_SAMPLE-PERSON_SAMPLED.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EHQUN, internal->external for field FLOW_RATE_START CALL FUNCTION 'CONVERSION_EXIT_EHQUN_OUTPUT' EXPORTING input = WA_EHHSSS_UI_SPLNG_SAMPLE-FLOW_RATE_START IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_UI_SPLNG_SAMPLE-FLOW_RATE_START.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EHQUN, internal->external for field FLOW_RATE_END CALL FUNCTION 'CONVERSION_EXIT_EHQUN_OUTPUT' EXPORTING input = WA_EHHSSS_UI_SPLNG_SAMPLE-FLOW_RATE_END IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_UI_SPLNG_SAMPLE-FLOW_RATE_END.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EHUNI, internal->external for field FLOW_RATE_UNIT CALL FUNCTION 'CONVERSION_EXIT_EHUNI_OUTPUT' EXPORTING input = WA_EHHSSS_UI_SPLNG_SAMPLE-FLOW_RATE_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_UI_SPLNG_SAMPLE-FLOW_RATE_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field START_TIMESTAMP CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_EHHSSS_UI_SPLNG_SAMPLE-START_TIMESTAMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_UI_SPLNG_SAMPLE-START_TIMESTAMP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field END_TIMESTAMP CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_EHHSSS_UI_SPLNG_SAMPLE-END_TIMESTAMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_UI_SPLNG_SAMPLE-END_TIMESTAMP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EHCKR, internal->external for field PPE_WORN CALL FUNCTION 'CONVERSION_EXIT_EHCKR_OUTPUT' EXPORTING input = WA_EHHSSS_UI_SPLNG_SAMPLE-PPE_WORN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_UI_SPLNG_SAMPLE-PPE_WORN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit DFVAL, internal->external for field VALIDITY CALL FUNCTION 'CONVERSION_EXIT_DFVAL_OUTPUT' EXPORTING input = WA_EHHSSS_UI_SPLNG_SAMPLE-VALIDITY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_UI_SPLNG_SAMPLE-VALIDITY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EHMIN, internal->external for field LATITUDE CALL FUNCTION 'CONVERSION_EXIT_EHMIN_OUTPUT' EXPORTING input = WA_EHHSSS_UI_SPLNG_SAMPLE-LATITUDE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_UI_SPLNG_SAMPLE-LATITUDE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EHMIN, internal->external for field LONGITUDE CALL FUNCTION 'CONVERSION_EXIT_EHMIN_OUTPUT' EXPORTING input = WA_EHHSSS_UI_SPLNG_SAMPLE-LONGITUDE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_UI_SPLNG_SAMPLE-LONGITUDE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EHHSSS_UI_SPLNG_SAMPLE-ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_UI_SPLNG_SAMPLE-ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EHSPT, internal->external for field SHIFT_PATTERN CALL FUNCTION 'CONVERSION_EXIT_EHSPT_OUTPUT' EXPORTING input = WA_EHHSSS_UI_SPLNG_SAMPLE-SHIFT_PATTERN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_UI_SPLNG_SAMPLE-SHIFT_PATTERN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit THHMM, internal->external for field START_TIME CALL FUNCTION 'CONVERSION_EXIT_THHMM_OUTPUT' EXPORTING input = WA_EHHSSS_UI_SPLNG_SAMPLE-START_TIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_UI_SPLNG_SAMPLE-START_TIME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit THHMM, internal->external for field END_TIME CALL FUNCTION 'CONVERSION_EXIT_THHMM_OUTPUT' EXPORTING input = WA_EHHSSS_UI_SPLNG_SAMPLE-END_TIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_UI_SPLNG_SAMPLE-END_TIME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHHSSS_UI_SPLNG_SAMPLE_STR,
KEY TYPE STRING,
PARENT_KEY TYPE STRING,
ROOT_KEY TYPE STRING,
DATETIME_CR TYPE STRING,
USER_ID_CR TYPE STRING,
DATETIME_CH TYPE STRING,
USER_ID_CH TYPE STRING,
BLANK_INDICATOR TYPE STRING,
BLANK_TYPE TYPE STRING,
PERSON_SAMPLED TYPE STRING,
MEDIA_ID TYPE STRING,
EQUIPMENT_ID TYPE STRING,
EQUIPMENT_CALIBRATED_IND TYPE STRING,
FLOW_RATE_START TYPE STRING,
FLOW_RATE_END TYPE STRING,
FLOW_RATE_UNIT TYPE STRING,
START_TIMESTAMP TYPE STRING,
END_TIMESTAMP TYPE STRING,
PPE_WORN TYPE STRING,
CALIB_REPORT_KEY_REF TYPE STRING,
FIELD_SHEET_KEY_REF TYPE STRING,
VALIDITY TYPE STRING,
LATITUDE TYPE STRING,
LONGITUDE TYPE STRING,
ID TYPE STRING,
SHIFT_PATTERN TYPE STRING,
SUBSTANTIATION TYPE STRING,
IS_REVIEWED TYPE STRING,
EEW_SPLNG_SAMPLE_D TYPE STRING,
READABLE_ID TYPE STRING,
EEW_SPLNG_SAMPLE_DT TYPE STRING,
BLANK_SAMPLE_STRING TYPE STRING,
UPLOAD_FIELD_SHEET TYPE STRING,
UPLOAD_CALIB_REPORT TYPE STRING,
FIELD_SHEET_IMAGE TYPE STRING,
CALIB_REPORT_IMAGE TYPE STRING,
DELETE_FIELD_SHEET_ENABLED TYPE STRING,
DELETE_CALIB_REPORT_ENABLED TYPE STRING,
VALIDITY_CELL_DESIGN TYPE STRING,
START_TIME TYPE STRING,
END_TIME TYPE STRING,
FLOW_RATE_START_COMB TYPE STRING,
FIELD_SHEET_TOOLTIP TYPE STRING,
VALIDITY_TOOLTIP TYPE STRING,
CALIB_REPORT_TOOLTIP TYPE STRING,
FLOW_RATE_END_COMB TYPE STRING,
SAMPLE_TITLE TYPE STRING,
NOTIF_LETTER TYPE STRING,
NOTIF_LETTER_ENABLED TYPE STRING,
NOTIF_LETTER_TOOLTIP TYPE STRING,
NOTIF_LETTER_IMAGE TYPE STRING,
IS_REVIEWED_YES TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHHSSS_UI_SPLNG_SAMPLE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-KEY sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-PARENT_KEY sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-ROOT_KEY sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-DATETIME_CR sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-USER_ID_CR sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-DATETIME_CH sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-USER_ID_CH sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-BLANK_INDICATOR sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-BLANK_TYPE sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-PERSON_SAMPLED sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-MEDIA_ID sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-EQUIPMENT_ID sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-EQUIPMENT_CALIBRATED_IND sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-FLOW_RATE_START sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-FLOW_RATE_END sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-FLOW_RATE_UNIT sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-START_TIMESTAMP sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-END_TIMESTAMP sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-PPE_WORN sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-CALIB_REPORT_KEY_REF sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-FIELD_SHEET_KEY_REF sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-VALIDITY sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-LATITUDE sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-LONGITUDE sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-ID sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-SHIFT_PATTERN sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-SUBSTANTIATION sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-IS_REVIEWED sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-EEW_SPLNG_SAMPLE_D sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-READABLE_ID sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-EEW_SPLNG_SAMPLE_DT sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-BLANK_SAMPLE_STRING sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-UPLOAD_FIELD_SHEET sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-UPLOAD_CALIB_REPORT sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-FIELD_SHEET_IMAGE sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-CALIB_REPORT_IMAGE sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-DELETE_FIELD_SHEET_ENABLED sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-DELETE_CALIB_REPORT_ENABLED sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-VALIDITY_CELL_DESIGN sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-START_TIME sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-END_TIME sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-FLOW_RATE_START_COMB sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-FIELD_SHEET_TOOLTIP sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-VALIDITY_TOOLTIP sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-CALIB_REPORT_TOOLTIP sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-FLOW_RATE_END_COMB sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-SAMPLE_TITLE sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-NOTIF_LETTER sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-NOTIF_LETTER_ENABLED sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-NOTIF_LETTER_TOOLTIP sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-NOTIF_LETTER_IMAGE sy-vline
WA_EHHSSS_UI_SPLNG_SAMPLE_STR-IS_REVIEWED_YES sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.