ABAP Select data from SAP table EHHSSS_PIL_INCIDENT_LC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHHSSS_PIL_INCIDENT_LC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHHSSS_PIL_INCIDENT_LC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHHSSS_PIL_INCIDENT_LC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHHSSS_PIL_INCIDENT_LC TYPE STANDARD TABLE OF EHHSSS_PIL_INCIDENT_LC,
      WA_EHHSSS_PIL_INCIDENT_LC TYPE EHHSSS_PIL_INCIDENT_LC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHHSSS_PIL_INCIDENT_LC> TYPE EHHSSS_PIL_INCIDENT_LC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHHSSS_PIL_INCIDENT_LC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHHSSS_PIL_INCIDENT_LC
  INTO TABLE IT_EHHSSS_PIL_INCIDENT_LC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHHSSS_PIL_INCIDENT_LC
*  INTO TABLE @DATA(IT_EHHSSS_PIL_INCIDENT_LC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHHSSS_PIL_INCIDENT_LC INDEX 1 INTO DATA(WA_EHHSSS_PIL_INCIDENT_LC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHHSSS_PIL_INCIDENT_LC ASSIGNING <EHHSSS_PIL_INCIDENT_LC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHHSSS_PIL_INCIDENT_LC>-KEY = 1.
<EHHSSS_PIL_INCIDENT_LC>-PARENT_KEY = 1.
<EHHSSS_PIL_INCIDENT_LC>-ROOT_KEY = 1.
<EHHSSS_PIL_INCIDENT_LC>-DATETIME_CR = 1.
<EHHSSS_PIL_INCIDENT_LC>-USER_ID_CR = 1.
ENDLOOP.

LOOP AT IT_EHHSSS_PIL_INCIDENT_LC INTO WA_EHHSSS_PIL_INCIDENT_LC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHHSSS_PIL_INCIDENT_LC-DATETIME_CH, sy-vline,
WA_EHHSSS_PIL_INCIDENT_LC-USER_ID_CH, sy-vline,
WA_EHHSSS_PIL_INCIDENT_LC-INC_MGNR, sy-vline,
WA_EHHSSS_PIL_INCIDENT_LC-EEW_INC_TSM_D, sy-vline,
WA_EHHSSS_PIL_INCIDENT_LC-INC_SHORT_INFO, sy-vline,
WA_EHHSSS_PIL_INCIDENT_LC-INC_DESCR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHHSSS_PIL_INCIDENT_LC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHHSSS_PIL_INCIDENT_LC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHHSSS_PIL_INCIDENT_LC INTO WA_EHHSSS_PIL_INCIDENT_LC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TSTLC, internal->external for field DATETIME_CR CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_EHHSSS_PIL_INCIDENT_LC-DATETIME_CR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_PIL_INCIDENT_LC-DATETIME_CR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field DATETIME_CH CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_EHHSSS_PIL_INCIDENT_LC-DATETIME_CH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSS_PIL_INCIDENT_LC-DATETIME_CH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHHSSS_PIL_INCIDENT_LC_STR,
KEY TYPE STRING,
PARENT_KEY TYPE STRING,
ROOT_KEY TYPE STRING,
DATETIME_CR TYPE STRING,
USER_ID_CR TYPE STRING,
DATETIME_CH TYPE STRING,
USER_ID_CH TYPE STRING,
INC_MGNR TYPE STRING,
EEW_INC_TSM_D TYPE STRING,
INC_SHORT_INFO TYPE STRING,
INC_DESCR TYPE STRING,
INC_DATE_FORMATTED TYPE STRING,
INC_ID_FORMATTED TYPE STRING,
INC_LOC_FORMATTED TYPE STRING,
INC_MNGR_NAME TYPE STRING,
INC_MNGR_EMAIL TYPE STRING,
EEW_INC_TSM_DT TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHHSSS_PIL_INCIDENT_LC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHHSSS_PIL_INCIDENT_LC_STR-KEY sy-vline
WA_EHHSSS_PIL_INCIDENT_LC_STR-PARENT_KEY sy-vline
WA_EHHSSS_PIL_INCIDENT_LC_STR-ROOT_KEY sy-vline
WA_EHHSSS_PIL_INCIDENT_LC_STR-DATETIME_CR sy-vline
WA_EHHSSS_PIL_INCIDENT_LC_STR-USER_ID_CR sy-vline
WA_EHHSSS_PIL_INCIDENT_LC_STR-DATETIME_CH sy-vline
WA_EHHSSS_PIL_INCIDENT_LC_STR-USER_ID_CH sy-vline
WA_EHHSSS_PIL_INCIDENT_LC_STR-INC_MGNR sy-vline
WA_EHHSSS_PIL_INCIDENT_LC_STR-EEW_INC_TSM_D sy-vline
WA_EHHSSS_PIL_INCIDENT_LC_STR-INC_SHORT_INFO sy-vline
WA_EHHSSS_PIL_INCIDENT_LC_STR-INC_DESCR sy-vline
WA_EHHSSS_PIL_INCIDENT_LC_STR-INC_DATE_FORMATTED sy-vline
WA_EHHSSS_PIL_INCIDENT_LC_STR-INC_ID_FORMATTED sy-vline
WA_EHHSSS_PIL_INCIDENT_LC_STR-INC_LOC_FORMATTED sy-vline
WA_EHHSSS_PIL_INCIDENT_LC_STR-INC_MNGR_NAME sy-vline
WA_EHHSSS_PIL_INCIDENT_LC_STR-INC_MNGR_EMAIL sy-vline
WA_EHHSSS_PIL_INCIDENT_LC_STR-EEW_INC_TSM_DT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.