ABAP Select data from SAP table EHHSSS_GW_SAFINF_CHM_LOC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHHSSS_GW_SAFINF_CHM_LOC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHHSSS_GW_SAFINF_CHM_LOC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHHSSS_GW_SAFINF_CHM_LOC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHHSSS_GW_SAFINF_CHM_LOC TYPE STANDARD TABLE OF EHHSSS_GW_SAFINF_CHM_LOC,
      WA_EHHSSS_GW_SAFINF_CHM_LOC TYPE EHHSSS_GW_SAFINF_CHM_LOC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHHSSS_GW_SAFINF_CHM_LOC> TYPE EHHSSS_GW_SAFINF_CHM_LOC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHHSSS_GW_SAFINF_CHM_LOC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHHSSS_GW_SAFINF_CHM_LOC
  INTO TABLE IT_EHHSSS_GW_SAFINF_CHM_LOC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHHSSS_GW_SAFINF_CHM_LOC
*  INTO TABLE @DATA(IT_EHHSSS_GW_SAFINF_CHM_LOC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHHSSS_GW_SAFINF_CHM_LOC INDEX 1 INTO DATA(WA_EHHSSS_GW_SAFINF_CHM_LOC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHHSSS_GW_SAFINF_CHM_LOC ASSIGNING <EHHSSS_GW_SAFINF_CHM_LOC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHHSSS_GW_SAFINF_CHM_LOC>-CHEMICAL_ID = 1.
<EHHSSS_GW_SAFINF_CHM_LOC>-LOCATION_ID = 1.
<EHHSSS_GW_SAFINF_CHM_LOC>-LOCATION_NAME = 1.
<EHHSSS_GW_SAFINF_CHM_LOC>-CHEMICAL_NAME = 1.
<EHHSSS_GW_SAFINF_CHM_LOC>-COMPANY_INT_NAME = 1.
ENDLOOP.

LOOP AT IT_EHHSSS_GW_SAFINF_CHM_LOC INTO WA_EHHSSS_GW_SAFINF_CHM_LOC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHHSSS_GW_SAFINF_CHM_LOC-SIGNALWORD_DESC, sy-vline,
WA_EHHSSS_GW_SAFINF_CHM_LOC-RISK_LEVEL_CODE, sy-vline,
WA_EHHSSS_GW_SAFINF_CHM_LOC-RISK_VALUE_INHERENT, sy-vline,
WA_EHHSSS_GW_SAFINF_CHM_LOC-RISK_LEVEL_DESC, sy-vline,
WA_EHHSSS_GW_SAFINF_CHM_LOC-GENERAL_ADVICE_DESC, sy-vline,
WA_EHHSSS_GW_SAFINF_CHM_LOC-INHALATION_DESC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHHSSS_GW_SAFINF_CHM_LOC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHHSSS_GW_SAFINF_CHM_LOC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHHSSS_GW_SAFINF_CHM_LOC INTO WA_EHHSSS_GW_SAFINF_CHM_LOC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHHSSS_GW_SAFINF_CHM_LOC_STR,
CHEMICAL_ID TYPE STRING,
LOCATION_ID TYPE STRING,
LOCATION_NAME TYPE STRING,
CHEMICAL_NAME TYPE STRING,
COMPANY_INT_NAME TYPE STRING,
SIGNALWORD_DESC TYPE STRING,
RISK_LEVEL_CODE TYPE STRING,
RISK_VALUE_INHERENT TYPE STRING,
RISK_LEVEL_DESC TYPE STRING,
GENERAL_ADVICE_DESC TYPE STRING,
INHALATION_DESC TYPE STRING,
EYE_CONTACT_DESC TYPE STRING,
SKIN_CONTACT_DESC TYPE STRING,
INGESTION_DESC TYPE STRING,
PHYSICIAN_HINT_DESC TYPE STRING,
SUITABLE_MEDIA_DESC TYPE STRING,
UNSUITABLE_MEDIA_DESC TYPE STRING,
PERS_PRECAUTION_DESC TYPE STRING,
ENV_PRECAUTION_DESC TYPE STRING,
CLEANUP_METHOD_DESC TYPE STRING,
ATTACHMENT_COUNT TYPE STRING,
CHM_LOC_INCL TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHHSSS_GW_SAFINF_CHM_LOC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHHSSS_GW_SAFINF_CHM_LOC_STR-CHEMICAL_ID sy-vline
WA_EHHSSS_GW_SAFINF_CHM_LOC_STR-LOCATION_ID sy-vline
WA_EHHSSS_GW_SAFINF_CHM_LOC_STR-LOCATION_NAME sy-vline
WA_EHHSSS_GW_SAFINF_CHM_LOC_STR-CHEMICAL_NAME sy-vline
WA_EHHSSS_GW_SAFINF_CHM_LOC_STR-COMPANY_INT_NAME sy-vline
WA_EHHSSS_GW_SAFINF_CHM_LOC_STR-SIGNALWORD_DESC sy-vline
WA_EHHSSS_GW_SAFINF_CHM_LOC_STR-RISK_LEVEL_CODE sy-vline
WA_EHHSSS_GW_SAFINF_CHM_LOC_STR-RISK_VALUE_INHERENT sy-vline
WA_EHHSSS_GW_SAFINF_CHM_LOC_STR-RISK_LEVEL_DESC sy-vline
WA_EHHSSS_GW_SAFINF_CHM_LOC_STR-GENERAL_ADVICE_DESC sy-vline
WA_EHHSSS_GW_SAFINF_CHM_LOC_STR-INHALATION_DESC sy-vline
WA_EHHSSS_GW_SAFINF_CHM_LOC_STR-EYE_CONTACT_DESC sy-vline
WA_EHHSSS_GW_SAFINF_CHM_LOC_STR-SKIN_CONTACT_DESC sy-vline
WA_EHHSSS_GW_SAFINF_CHM_LOC_STR-INGESTION_DESC sy-vline
WA_EHHSSS_GW_SAFINF_CHM_LOC_STR-PHYSICIAN_HINT_DESC sy-vline
WA_EHHSSS_GW_SAFINF_CHM_LOC_STR-SUITABLE_MEDIA_DESC sy-vline
WA_EHHSSS_GW_SAFINF_CHM_LOC_STR-UNSUITABLE_MEDIA_DESC sy-vline
WA_EHHSSS_GW_SAFINF_CHM_LOC_STR-PERS_PRECAUTION_DESC sy-vline
WA_EHHSSS_GW_SAFINF_CHM_LOC_STR-ENV_PRECAUTION_DESC sy-vline
WA_EHHSSS_GW_SAFINF_CHM_LOC_STR-CLEANUP_METHOD_DESC sy-vline
WA_EHHSSS_GW_SAFINF_CHM_LOC_STR-ATTACHMENT_COUNT sy-vline
WA_EHHSSS_GW_SAFINF_CHM_LOC_STR-CHM_LOC_INCL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.