ABAP Select data from SAP table EHHSSD_CINSP_RC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHHSSD_CINSP_RC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHHSSD_CINSP_RC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHHSSD_CINSP_RC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHHSSD_CINSP_RC TYPE STANDARD TABLE OF EHHSSD_CINSP_RC,
      WA_EHHSSD_CINSP_RC TYPE EHHSSD_CINSP_RC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHHSSD_CINSP_RC> TYPE EHHSSD_CINSP_RC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHHSSD_CINSP_RC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHHSSD_CINSP_RC
  INTO TABLE IT_EHHSSD_CINSP_RC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHHSSD_CINSP_RC
*  INTO TABLE @DATA(IT_EHHSSD_CINSP_RC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHHSSD_CINSP_RC INDEX 1 INTO DATA(WA_EHHSSD_CINSP_RC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHHSSD_CINSP_RC ASSIGNING <EHHSSD_CINSP_RC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHHSSD_CINSP_RC>-MANDT = 1.
<EHHSSD_CINSP_RC>-DB_KEY = 1.
<EHHSSD_CINSP_RC>-PARENT_KEY = 1.
<EHHSSD_CINSP_RC>-DATETIME_CR = 1.
<EHHSSD_CINSP_RC>-USER_ID_CR = 1.
ENDLOOP.

LOOP AT IT_EHHSSD_CINSP_RC INTO WA_EHHSSD_CINSP_RC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHHSSD_CINSP_RC-DATETIME_CH, sy-vline,
WA_EHHSSD_CINSP_RC-USER_ID_CH, sy-vline,
WA_EHHSSD_CINSP_RC-CTRL_ROOT_KEY_REF, sy-vline,
WA_EHHSSD_CINSP_RC-LOC_ROOT_KEY_REF, sy-vline,
WA_EHHSSD_CINSP_RC-RSK_ROOT_KEY_REF, sy-vline,
WA_EHHSSD_CINSP_RC-EFFECTIVN_CODE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHHSSD_CINSP_RC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHHSSD_CINSP_RC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHHSSD_CINSP_RC INTO WA_EHHSSD_CINSP_RC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TSTLC, internal->external for field DATETIME_CR CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_EHHSSD_CINSP_RC-DATETIME_CR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSD_CINSP_RC-DATETIME_CR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field DATETIME_CH CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_EHHSSD_CINSP_RC-DATETIME_CH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSD_CINSP_RC-DATETIME_CH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit LCRID, internal->external for field LOC_ROOT_KEY_REF CALL FUNCTION 'CONVERSION_EXIT_LCRID_OUTPUT' EXPORTING input = WA_EHHSSD_CINSP_RC-LOC_ROOT_KEY_REF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSD_CINSP_RC-LOC_ROOT_KEY_REF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EHEFF, internal->external for field EFFECTIVN_CODE CALL FUNCTION 'CONVERSION_EXIT_EHEFF_OUTPUT' EXPORTING input = WA_EHHSSD_CINSP_RC-EFFECTIVN_CODE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSD_CINSP_RC-EFFECTIVN_CODE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit DFVAL, internal->external for field ACCEPTED_IND CALL FUNCTION 'CONVERSION_EXIT_DFVAL_OUTPUT' EXPORTING input = WA_EHHSSD_CINSP_RC-ACCEPTED_IND IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHHSSD_CINSP_RC-ACCEPTED_IND.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHHSSD_CINSP_RC_STR,
MANDT TYPE STRING,
DB_KEY TYPE STRING,
PARENT_KEY TYPE STRING,
DATETIME_CR TYPE STRING,
USER_ID_CR TYPE STRING,
DATETIME_CH TYPE STRING,
USER_ID_CH TYPE STRING,
CTRL_ROOT_KEY_REF TYPE STRING,
LOC_ROOT_KEY_REF TYPE STRING,
RSK_ROOT_KEY_REF TYPE STRING,
EFFECTIVN_CODE TYPE STRING,
REMARK TYPE STRING,
COMMENT TYPE STRING,
ACCEPTED_IND TYPE STRING,
EEW_CINSP_RSK_CTRL_D TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHHSSD_CINSP_RC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHHSSD_CINSP_RC_STR-MANDT sy-vline
WA_EHHSSD_CINSP_RC_STR-DB_KEY sy-vline
WA_EHHSSD_CINSP_RC_STR-PARENT_KEY sy-vline
WA_EHHSSD_CINSP_RC_STR-DATETIME_CR sy-vline
WA_EHHSSD_CINSP_RC_STR-USER_ID_CR sy-vline
WA_EHHSSD_CINSP_RC_STR-DATETIME_CH sy-vline
WA_EHHSSD_CINSP_RC_STR-USER_ID_CH sy-vline
WA_EHHSSD_CINSP_RC_STR-CTRL_ROOT_KEY_REF sy-vline
WA_EHHSSD_CINSP_RC_STR-LOC_ROOT_KEY_REF sy-vline
WA_EHHSSD_CINSP_RC_STR-RSK_ROOT_KEY_REF sy-vline
WA_EHHSSD_CINSP_RC_STR-EFFECTIVN_CODE sy-vline
WA_EHHSSD_CINSP_RC_STR-REMARK sy-vline
WA_EHHSSD_CINSP_RC_STR-COMMENT sy-vline
WA_EHHSSD_CINSP_RC_STR-ACCEPTED_IND sy-vline
WA_EHHSSD_CINSP_RC_STR-EEW_CINSP_RSK_CTRL_D sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.