ABAP Select data from SAP table EHFNDW_SRFIREPNT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP EHFNDW_SRFIREPNT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EHFNDW_SRFIREPNT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the EHFNDW_SRFIREPNT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_EHFNDW_SRFIREPNT TYPE STANDARD TABLE OF EHFNDW_SRFIREPNT,
      WA_EHFNDW_SRFIREPNT TYPE EHFNDW_SRFIREPNT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <EHFNDW_SRFIREPNT> TYPE EHFNDW_SRFIREPNT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_EHFNDW_SRFIREPNT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM EHFNDW_SRFIREPNT
  INTO TABLE IT_EHFNDW_SRFIREPNT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM EHFNDW_SRFIREPNT
*  INTO TABLE @DATA(IT_EHFNDW_SRFIREPNT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_EHFNDW_SRFIREPNT INDEX 1 INTO DATA(WA_EHFNDW_SRFIREPNT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_EHFNDW_SRFIREPNT ASSIGNING <EHFNDW_SRFIREPNT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<EHFNDW_SRFIREPNT>-MANDT = 1.
<EHFNDW_SRFIREPNT>-PCSFTYFIREPOINTPRPTYUUID = 1.
<EHFNDW_SRFIREPNT>-PCSFTYPRPTYUUID = 1.
<EHFNDW_SRFIREPNT>-CREATIONUTCDATETIME = 1.
<EHFNDW_SRFIREPNT>-CREATEDBYUSER = 1.
ENDLOOP.

LOOP AT IT_EHFNDW_SRFIREPNT INTO WA_EHFNDW_SRFIREPNT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_EHFNDW_SRFIREPNT-LASTCHANGEUTCDATETIME, sy-vline,
WA_EHFNDW_SRFIREPNT-LASTCHANGEDBYUSER, sy-vline,
WA_EHFNDW_SRFIREPNT-PCSFTYFIREPOINTTEMPLOWRQTYOPTR, sy-vline,
WA_EHFNDW_SRFIREPNT-PCSFTYFIREPOINTTEMPLOWRQTY, sy-vline,
WA_EHFNDW_SRFIREPNT-PCSFTYFIREPOINTTEMPLOWRQTYTXT, sy-vline,
WA_EHFNDW_SRFIREPNT-PCSFTYFIREPOINTTEMPUPRQTYOPTR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EHFNDW_SRFIREPNT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EHFNDW_SRFIREPNT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EHFNDW_SRFIREPNT INTO WA_EHFNDW_SRFIREPNT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field PCSFTYFIREPOINTTEMPQTYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_EHFNDW_SRFIREPNT-PCSFTYFIREPOINTTEMPQTYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EHFNDW_SRFIREPNT-PCSFTYFIREPOINTTEMPQTYUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EHFNDW_SRFIREPNT_STR,
MANDT TYPE STRING,
PCSFTYFIREPOINTPRPTYUUID TYPE STRING,
PCSFTYPRPTYUUID TYPE STRING,
CREATIONUTCDATETIME TYPE STRING,
CREATEDBYUSER TYPE STRING,
LASTCHANGEUTCDATETIME TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
PCSFTYFIREPOINTTEMPLOWRQTYOPTR TYPE STRING,
PCSFTYFIREPOINTTEMPLOWRQTY TYPE STRING,
PCSFTYFIREPOINTTEMPLOWRQTYTXT TYPE STRING,
PCSFTYFIREPOINTTEMPUPRQTYOPTR TYPE STRING,
PCSFTYFIREPOINTTEMPUPRQTY TYPE STRING,
PCSFTYFIREPOINTTEMPUPRQTYTXT TYPE STRING,
PCSFTYFIREPOINTTEMPQTYUNIT TYPE STRING,
PCSFTYNOTETEXT TYPE STRING,
PCSFTYASSESSMENTPHRSUUID TYPE STRING,
PCSFTYHASNOAPPL TYPE STRING,
PCSFTYHASNODATA TYPE STRING,
ACTIVEUUID TYPE STRING,
HASACTIVEENTITY TYPE STRING,
DRAFTENTITYCREATIONDATETIME TYPE STRING,
DRAFTENTITYLASTCHANGEDATETIME TYPE STRING,
DRAFTADMINISTRATIVEDATAUUID TYPE STRING,
DRAFTENTITYCONSISTENCYSTATUS TYPE STRING,
DRAFTENTITYOPERATIONCODE TYPE STRING,END OF T_EKKO_STR. DATA: WA_EHFNDW_SRFIREPNT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EHFNDW_SRFIREPNT_STR-MANDT sy-vline
WA_EHFNDW_SRFIREPNT_STR-PCSFTYFIREPOINTPRPTYUUID sy-vline
WA_EHFNDW_SRFIREPNT_STR-PCSFTYPRPTYUUID sy-vline
WA_EHFNDW_SRFIREPNT_STR-CREATIONUTCDATETIME sy-vline
WA_EHFNDW_SRFIREPNT_STR-CREATEDBYUSER sy-vline
WA_EHFNDW_SRFIREPNT_STR-LASTCHANGEUTCDATETIME sy-vline
WA_EHFNDW_SRFIREPNT_STR-LASTCHANGEDBYUSER sy-vline
WA_EHFNDW_SRFIREPNT_STR-PCSFTYFIREPOINTTEMPLOWRQTYOPTR sy-vline
WA_EHFNDW_SRFIREPNT_STR-PCSFTYFIREPOINTTEMPLOWRQTY sy-vline
WA_EHFNDW_SRFIREPNT_STR-PCSFTYFIREPOINTTEMPLOWRQTYTXT sy-vline
WA_EHFNDW_SRFIREPNT_STR-PCSFTYFIREPOINTTEMPUPRQTYOPTR sy-vline
WA_EHFNDW_SRFIREPNT_STR-PCSFTYFIREPOINTTEMPUPRQTY sy-vline
WA_EHFNDW_SRFIREPNT_STR-PCSFTYFIREPOINTTEMPUPRQTYTXT sy-vline
WA_EHFNDW_SRFIREPNT_STR-PCSFTYFIREPOINTTEMPQTYUNIT sy-vline
WA_EHFNDW_SRFIREPNT_STR-PCSFTYNOTETEXT sy-vline
WA_EHFNDW_SRFIREPNT_STR-PCSFTYASSESSMENTPHRSUUID sy-vline
WA_EHFNDW_SRFIREPNT_STR-PCSFTYHASNOAPPL sy-vline
WA_EHFNDW_SRFIREPNT_STR-PCSFTYHASNODATA sy-vline
WA_EHFNDW_SRFIREPNT_STR-ACTIVEUUID sy-vline
WA_EHFNDW_SRFIREPNT_STR-HASACTIVEENTITY sy-vline
WA_EHFNDW_SRFIREPNT_STR-DRAFTENTITYCREATIONDATETIME sy-vline
WA_EHFNDW_SRFIREPNT_STR-DRAFTENTITYLASTCHANGEDATETIME sy-vline
WA_EHFNDW_SRFIREPNT_STR-DRAFTADMINISTRATIVEDATAUUID sy-vline
WA_EHFNDW_SRFIREPNT_STR-DRAFTENTITYCONSISTENCYSTATUS sy-vline
WA_EHFNDW_SRFIREPNT_STR-DRAFTENTITYOPERATIONCODE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.